Search results for "RESONANCE"

showing 10 items of 6625 documents

Stress cardiac magnetic resonance for mortality prediction and decision-making: registry of 2496 elderly patients with chronic coronary syndrome

2022

Abstract Introduction and objectives The management of elderly patients with chronic coronary syndrome (CCS) is challenging. We explored the prognostic value and usefulness for decision-making of ischemic burden determined by vasodilator stress cardiac magnetic resonance (CMR) imaging in elderly patients with known or suspected CCS. Methods The study group comprised 2496 patients older than 70 years who underwent vasodilator stress CMR for known or suspected CCS. The ischemic burden (number of segments with stress-induced perfusion deficit) was calculated following the 17-segment model. Subsequently, we retrospectively analyzed its association with all-cause mortality and the effect of CMR-…

medicine.medical_specialtyMagnetic Resonance SpectroscopyVasodilator stressVasodilator Agentsmedicine.medical_treatmentIschemiaMagnetic Resonance Imaging CineCoronary Artery DiseaseIndependent predictorRevascularizationPredictive Value of TestsRisk FactorsInternal medicinemedicineHumansIn patientRegistriesMortality predictionAgedRetrospective Studiesbusiness.industryGeneral MedicinePrognosismedicine.diseaseMagnetic Resonance ImagingCardiologyFemalebusinessCardiac magnetic resonancePerfusionRevista Española de Cardiología (English Edition)
researchProduct

Magnesium metabolism in hypertension and type 2 diabetes mellitus.

2007

The increasing evidence for the clinical relevance of altered magnesium metabolism to states of altered insulin resistance confirms the role of magnesium deficit as a possible underlying common mechanism of the "insulin resistance" of hypertension and altered glucose tolerance. The pioneer work of Lawrence M. Resnick and his group using the cellular ion-based approach that we are only partially presenting here has consistently contributed to the progress of the field, demonstrating (a) the critical importance of magnesium metabolism in regulating insulin sensitivity as well as vascular tone, and blood-pressure homeostasis; (b) that magnesium deficiency, defined on the basis of intracellular…

medicine.medical_specialtyMagnetic Resonance Spectroscopychemistry.chemical_elementEssential hypertensionInsulin resistancePre-EclampsiaPregnancyMagnesium deficiency (medicine)Diabetes mellitusInternal medicinemedicineHumansPharmacology (medical)MagnesiumSodium Chloride DietaryPharmacologyCalcium metabolismMagnesiumbusiness.industryType 2 Diabetes MellitusGeneral MedicineSyndromemedicine.diseaseEndocrinologychemistryDiabetes Mellitus Type 2HypertensionCalciumFemaleInsulin ResistancebusinessMagnesium DeficiencyHomeostasisAmerican journal of therapeutics
researchProduct

Magnetic resonance cholangiopancreatography

2002

With the introduction of endoscopic retrograde cholangio-pancreatography in the early 1970s, gastroenterologists have a lot of diagnostic options in the biliopancreatic system to their disposal. Meanwhile, magnetic resonance cholangiopancreatography (MRCP) has become a competitive replacement for diagnostic ERCP with the advantage of avoiding complications related to endoscopic techniques. Mounting evidence suggests that both MRCP and MRI (magnetic resonance imaging) have a profound influence of diagnostic algorithms in a variety of hepatobiliary and pancreatic diseases.

medicine.medical_specialtyMagnetic resonance cholangiopancreatographyHepatologymedicine.diagnostic_testbusiness.industryEndocrinology Diabetes and MetabolismGastroenterologymedicineMagnetic resonance imagingDiagnostic algorithmsRadiologybusinessPancreatology
researchProduct

Undetected Malignancies of the Breast: Dynamic Contrast-enhanced MR Imaging at 1.0 T

2002

To assess the prevalence and characteristics of malignant breast lesions not identified with magnetic resonance (MR) imaging.Breast tissue specimens were obtained in 464 of 967 patients who had undergone dynamic gadolinium-enhanced T1-weighted fast low-angle shot three-dimensional MR imaging of both breasts. A comparison of sensitivity, specificity, and predictive values of the prospectively recorded findings of mammography, ultrasonography (US), and MR imaging with the histopathologic results was performed with receiver operating characteristic (ROC) curve analysis. MR imaging examination findings that caused a false-negative diagnosis were reviewed to identify possible sources of error.Hi…

medicine.medical_specialtyMammary glandBreast NeoplasmsGadoliniumSensitivity and SpecificityPredictive Value of TestsmedicineHumansMammographyRadiology Nuclear Medicine and imagingmedicine.diagnostic_testReceiver operating characteristicbusiness.industryCurve analysisMagnetic resonance imagingImage EnhancementMagnetic Resonance ImagingMr imagingDynamic contrastmedicine.anatomical_structureROC CurveFemaleHistopathologyUltrasonography MammaryRadiologyArtifactsNuclear medicinebusinessRadiology
researchProduct

Giant schwannoma of the foot: a case report and literature review

2017

A schwannoma is a rare, benign tumor originating from Schwann cells of peripheral nerve sheath. It commonly occurs in subjects between 20 and 50 years of age, and its malignant transformation is exceptional. While schwannomas usually affect the head and neck region, localization in the lower extremity is exceptionally rare, and even fewer cases have described schwannomas occurring in the foot. We report a case of a giant schwannoma of the foot diagnosed in a 65-year-old woman. A giant schwannoma of the foot is an extremely rare soft tissue tumor. MRI may allow an earlier diagnosis and provide valuable information about the size and possible bone invasion. This case report noted that a compl…

medicine.medical_specialtyMaterials Science (miscellaneous)Case ReportSchwannomaMalignant transformationBenign tumor03 medical and health sciences0302 clinical medicineforefoot; giant schwannona; magnetic resonance imagingmedicineotorhinolaryngologic diseasesmagnetic resonance imagingPeripheral Nerve Sheath030222 orthopedicsmedicine.diagnostic_testbusiness.industryForefootgiant schwannonaSoft tissueMagnetic resonance imaging030229 sport sciencesmedicine.diseasenervous system diseasesforefootRadiologybusinessFoot (unit)
researchProduct

Quantitative myocardial perfusion magnetic resonance imaging: the impact of pulsatile flow on contrast agent bolus dispersion.

2011

Myocardial blood flow (MBF) can be quantified using T1-weighted first-pass magnetic resonance imaging (MRI) in combination with a tracer-kinetic model, like MMID4. This procedure requires the knowledge of an arterial input function which is usually estimated from the left ventricle (LV). Dispersion of the contrast agent bolus may occur between the LV and the tissue of interest. The aim of this study was to investigate the dispersion under conditions of physiological pulsatile blood flow, and to simulate its effect on MBF quantification. The dispersion was simulated in coronary arteries using a computational fluid dynamics (CFD) approach. Simulations were accomplished on straight vessels wit…

medicine.medical_specialtyMaterials scienceTime FactorsRadiological and Ultrasound Technologymedicine.diagnostic_testPulsatile flowMyocardial Perfusion ImagingContrast MediaMagnetic resonance imagingBlood flowMagnetic Resonance ImagingCoronary arteriesDiffusionCoronary circulationmedicine.anatomical_structureInternal medicineCoronary CirculationPulsatile FlowDispersion (optics)medicineCardiologyRadiology Nuclear Medicine and imagingBolus (digestion)Perfusioncirculatory and respiratory physiologyPhysics in medicine and biology
researchProduct

Evaluation of Skin Melanoma in Spectral Range 450-950 nm Using Principal Component Analysis

2013

Diagnostic potential of principal component analysis (PCA) of multi-spectral imaging data in the wavelength range 450-950 nm for distant skin melanoma recognition is discussed. Processing of the measured clinical data by means of PCA resulted in clear separation between malignant melanomas and pigmented nevi.

medicine.medical_specialtyMaterials scienceintegumentary systemWavelength rangebusiness.industryMelanomamedicine.diseaseImaging dataSpectral imagingOpticsNuclear magnetic resonancePrincipal component analysisPigmented NevusmedicineSkin melanomabusinessneoplasms
researchProduct

Quantitative contrast-enhanced myocardial perfusion magnetic resonance imaging: Simulation of bolus dispersion in constricted vessels

2009

Quantification of myocardial blood flow (MBF) by means of T 1 -weighted first-pass magnetic resonance imaging(MRI) requires knowledge of the arterial input function (AIF), which is usually estimated from the left ventricle (LV). Dispersion of the contrast agent bolus may occur between the LV and the tissue of interest, which leads to systematic underestimation of the MBF. The aim of this study was to simulate the dispersion along a simplified coronary artery with different stenoses. To analyze the dispersion in vessels with typical dimensions of coronary arteries, simulations were performed using the computational fluid dynamics approach. Simulations were accomplished on straight vessels wi…

medicine.medical_specialtyMaterials sciencemedicine.diagnostic_testResting state fMRIHemodynamicsMagnetic resonance imagingGeneral MedicineBlood flowCoronary arteriesmedicine.anatomical_structureVentricleInternal medicinemedicineCardiologyPerfusionArteryMedical Physics
researchProduct

In-vitro-Untersuchung von biologischen und technischen Herzklappenprothesen im MRT: Beurteilung möglicher Anziehung und Erhitzung der Implantate

2000

PURPOSE In vitro evaluation of possible deflection and heating of present-day prosthetic heart valves during MR imaging at 1.5 T. METHODS 17 prosthetic heart valves, 12 technical and 5 biological, were investigated using a 1.5 Tesla Siemens Vision system. Deflection was measured at the edge of a 1.5 Tesla superconducting magnet. Each valve was then submerged in a vial of a 1/1 electrolyte solution and temperature was measured before and after imaging with a turbo-spin-echo sequence (TR 5200 ms, TE 138 ms, Flip angle 180 degrees, acquisition time 10.5 minutes, length of echo train 29). MR imaging was performed with phase encoding parallel and perpendicular to the plane of the valves. RESULTS…

medicine.medical_specialtyMaterials sciencemedicine.diagnostic_testmedicine.medical_treatmentMagnetic resonance imagingBiological effectMr imagingProsthesisSurgerymedicine.anatomical_structureFlip anglemedicineRadiology Nuclear Medicine and imagingAcquisition timeHeart valveBiomedical engineeringProsthetic heartRöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren
researchProduct

Stafne's bone cavity: An unusual case with involvement of the buccal and lingual mandibular plates

2014

Lingual mandibular bone defects, also known as Stafne bone cavity (SC), are unilateral asymptomatic radiolucencies, generally seen in the mandibular angle, below the inferior alveolar canal. Although panoramic radiographies normally offer enough information to make a correct diagnosis, additional studies are often required, especially in atypical cases. The present report describes an atypical presentation of a Stafne’s bone cavity in a 78 years-old male patient. In this particular case, an asymptomatic and radiolucid lesion was observed during a routine dental examination. The computed tomography (CT) showed an involvement of both lingual and buccal mandibular plates producing a tunnel-lik…

medicine.medical_specialtyMaxillofacial surgeryOdontologíaCase ReportJawsMandibular angleAsymptomaticLesionstomatognathic systemmedicineGeneral DentistryOrthodonticsUnusual caseOral Medicine and Pathologymedicine.diagnostic_testMaxil·larsCirurgiabusiness.industryMagnetic resonance imagingBuccal administration:CIENCIAS MÉDICAS [UNESCO]Ciencias de la saludSurgerystomatognathic diseasesCirurgia maxil·lofacialDental examinationUNESCO::CIENCIAS MÉDICASSurgerymedicine.symptomPresentation (obstetrics)business
researchProduct