Search results for "RESTOR"
showing 10 items of 670 documents
Narrow-diameter implants: A systematic review and meta-analysis.
2018
OBJECTIVES Narrow-diameter implants (NDI) are claimed to be a reasonable alternative to bone augmentation procedures. The aim of this comprehensive literature review was to conduct a meta-analysis comparing the implant survival of NDI and standard diameter implants (SDI) and to provide recommendations and guidelines for application of NDI. MATERIAL AND METHODS An extensive systematic literature search was performed in the PubMed/MEDLINE and the Cochrane Library databases. NDI were classified into Category 1 (implant diameter <3.0 mm, "mini-implants"), Category 2 (implant diameter 3-3.25 mm) and Category 3 (implant diameters 3.3-3.5 mm). Clinical studies at all levels of evidence with at lea…
Optical calibration of a multispectral imaging system based on interference filters
2005
We present a new approach to optically calibrate a multispectral imaging system based on interference filters. Such a system typically suffers from some blurring of its channel images. Because the effectiveness of spectrum reconstruction depends heavily on the quality of the acquired channel images, and because this blurring negatively affects them, a method for deblurring and denoising them is required. The blur is modeled as a uniform intensity distribution within a circular disk. It allows us to characterize, quantitatively, the degradation for each channel image. In terms of global reduction of the blur, it consists of the choice of the best channel for the focus adjustment according to…
Quasi-Newton approach to nonnegative image restorations
2000
Abstract Image restoration, or deblurring, is the process of attempting to correct for degradation in a recorded image. Typically the blurring system is assumed to be linear and spatially invariant, and fast Fourier transform (FFT) based schemes result in efficient computational image restoration methods. However, real images have properties that cannot always be handled by linear methods. In particular, an image consists of positive light intensities, and thus a nonnegativity constraint should be enforced. This constraint and other ways of incorporating a priori information have been suggested in various applications, and can lead to substantial improvements in the reconstructions. Neverth…
THE SAN VITO WOODEN PULPIT FROM MUSEO DIOCESANO OF PALERMO, ITALY: MULTIDISCIPLINARY APPROACH AND ANALYTICAL TECHNIQUES FOR DATING AND RESTORATION
2017
The aim of the present research is to investigate the constitutive materials and the execution techniques of San Vito wooden pulpit from Museo Diocesano of Palermo (Italy) and to provide helpful information to dating it in addition to technical, historical and artistic evaluations. The pulpit, attributed to unknown artist, belongs to the decorative arts and the most relevant feature is its double dating, in addition to the singular painting technique: it has a linear structure typical of XIXth century and three polychrome and gilded panels probably dated to the end of XVIIth century. This paper describes the application of analytical techniques (imaging diagnostics techniques, Scanning Elec…
Risk factors associated with early failure of dental implants. A literature review
2010
The aim of the study was to examine articles published on risk factors associated with early failure of dental implants. We conducted a search on PubMed for articles published between January 2000 and December 2009 using the keywords 'dental implants' and 'early failure'. Seven studies that specified the number of early failed implants and studied the associated risk factors were included. Early failures are caused by the inability of tissue to establish osseointegration prior to prosthetic restoration; however the causal factors and mechanisms are unclear. In the reviewed literature there was a higher percentage of early than late failures; nevertheless, few articles were found that analyz…
A Prospective Noninterventional Study to Evaluate Survival and Success of Reduced Diameter Implants Made From Titanium-Zirconium Alloy
2015
Narrow diameter implants may be at increased risk of overload due to occlusal forces; therefore, implants with higher fatigue strength may be beneficial. The aim of this observational study was to evaluate survival and success of narrow diameter (Ø 3.3 mm) TiZr alloy (Roxolid, Institut Straumann AG, Basel, Switzerland) implants for 2 years in daily dental practice. This was a prospective, non-interventional, multicenter study; no specific patient inclusion or exclusion criteria were applied. Each patient received at least one TiZr implant; the treatment plan, including implant loading and final restoration, was at the investigator's discretion. The primary outcome was implant survival and s…
Meta-analysis on the survival of short implants
2010
Objective: To evaluate the success and failure rates of short implants (10 mm or less) for oral rehabilitations in cases of limited bone height. Study Design: Review of the articles published on the topic between the years 2000 and 2010, and development of a descriptive meta-analysis of the results. Results: The majority of the studies obtain a cumulative success rate (CSR) similar to that of longer implants (92.5% - 98.42% for machined and rough-surface implants, respectively). The studies that record lower cumulative success rates (CSR) are later studies that analyze implants with a machined surface. Almost none of the studi-es compared the success/failure rates with the bone quality or l…
Evaluation of marginal leakage after mechanical fatigue cycling of composite inlays luted with different cements
2018
This in vitro study evaluated the marginal microleakage of composite inlays luted with 3 different cement systems. The null hypothesis was that the luting materials would not influence dye penetration, showing the same degree of microleakage. Thirty-six sound molars were selected, mesio-occlusodistal cavities were prepared, and the teeth were randomly divided into 3 groups (n = 12). Composite resin inlay restorations were made and cemented using a dual-curing resin cement (Calibra), a light-curing flowable composite (Charisma Flow), or a self-adhesive resin cement (RelyX Unicem). The restored teeth were subjected to fatigue cycles and immersed in 0.5% basic fuchsin dye for 24 hours. Two ort…
Influence of bruxism on survival of porcelain laminate veneers
2013
Objectives: This study aims to determine whether bruxism and the use of occlusal splints affect the survival of porcelain laminate veneers in patients treated with this technique. Material and Methods: Restorations were made in 70 patients, including 30 patients with some type of parafunc - tional habit. A total of 323 veneers were placed, 170 in patients with bruxism activity, and the remaining 153 in patients without it. A clinical examination determined the presence or absence of ceramic failure (cracks, frac - tures and debonding) of the restorations; these incidents were analyzed for association with bruxism and the use of splints. Results: Analysis of the ceramic failures showed that …
A prospective evaluation of zirconia anterior partial fixed dental prostheses: Clinical results after seven years.
2014
Abstract Statement of problem Because of the high mechanical strength of zirconium dioxide, the metal in fixed partial prostheses can now be replaced. However, the material is susceptible to aging or hydrothermal degradation and to chipping of the feldspathic veneer. Purpose The purpose of this prospective study was to evaluate the survival (without failure) and success (survival without any complication or failure) rate and clinical efficacy of anterior zirconia partial fixed dental prostheses. Material and methods Twenty-seven anterior partial fixed dental prostheses of 3 to 6 units were fabricated. All participants were examined after 1 month and 6 months, then annually for 7 years. Resu…