Search results for "RIZ"
showing 10 items of 9613 documents
Semi-automatic detection of skin malformations by analysis of spectral images
2013
The multi-spectral imaging technique to reveal skin malformations has been described in this work. Four spectral images taken at polarized monochromatic LED illumination (450nm, 545nm, 660nm and 940 nm) and polarized white LED light imaged by CMOS sensor via cross-oriented polarizing filter were analyzed to calculate chromophore maps. The algorithm based on skin color analysis and user-defined threshold selection allows highlighting of skin areas with predefined chromophore concentration semi-automatically. Preliminary results of clinical tests are presented.
Requirements on resolution of digital imaging equipment in the cardiac catheterization laboratory.
1988
We evaluated the requirements on spatial resolution of digital imaging equipment in the cardiac catheterization laboratory. Fifty cinefilms of the heart as the biological object and one film of a lead-ladder-pattern as an objective test were used. The patient films were examined for the visibility of the left ventricular angiogram, coronary arterial tree, coronary artery lesions, branching of septal arteries and the number of septal arteries. All films were viewed three times: with a 625 line TV-system, with a 1249 line TV-system and with a cineprojector. It was found that two application areas with different demands on the spatial and temporal resolution can be distinguished: 1) low spatia…
Advanced Protocol for Three-Dimensional Transesophageal Echocardiography Guidance Implementing Real-Time Multiplanar Reconstruction for Transcatheter…
2019
Transcatheter direct annuloplasty has been introduced as a novel interventional treatment option for severe mitral valve regurgitation. Until now, only one direct annuloplasty device (Edwards Cardioband) has been commercially available, being implanted in more than 250 patients worldwide. Yet this procedure poses greater challenges regarding optimal fluoroscopic and echocardiographic guidance compared with edge-to-edge repair: correct localization and orientation of the anchors upon penetration into the fibrous mitral annulus tissue and the basal left ventricular myocardium are preconditions for an optimal result and essential to avoid damage of the neighboring structures (atrioventricular …
Feasibility of a MPR-based 3DTEE guidance protocol for transcatheter direct mitral valve annuloplasty.
2020
Objectives Several interventional approaches have been established for the treatment of severe mitral regurgitation (MR) in patients at elevated risk for surgery. Direct annuloplasty is a relatively novel option in transcatheter mitral valve repair dedicated to reverse pathology in specific subsets of MR. With regard to echocardiographic guidance, this procedure presents with higher efforts in comparison with edge-to-edge therapy to enable safe and exact positioning of the device's anchors; evidence on optimal peri-interventional imaging is sparse. We tested a specific 3D-echo-guidance protocol implementing single-beat multiplanar reconstruction (MPR) and evaluated its feasibility. Methods …
Amulet or Watchman Device for Percutaneous Left Atrial Appendage Closure: Primary Results of the SWISS-APERO Randomized Clinical Trial.
2022
Background:No study has so far compared Amulet with the new Watchman FLX in terms of residual left atrial appendage (LAA) patency or clinical outcomes in patients undergoing percutaneous LAA closure.Methods:In the investigator-initiated SWISS APERO trial (Comparison of Amulet Versus Watchman/FLX Device in Patients Undergoing Left Atrial Appendage Closure), patients undergoing LAA closure were randomly assigned (1:1) open label to receive Amulet or Watchman 2.5 or FLX (Watchman) across 8 European centers. The primary end point was the composite of justified crossover to a nonrandomized device during LAA closure procedure or residual LAA patency detected by cardiac computed tomography angiogr…
Simulation of left ventricular outflow tract (LVOT) obstruction in transcatheter mitral valve-in-ring replacement.
2020
Left ventricular outflow tract (LVOT) obstruction is a feared complication of transcatheter mitral valve replacement (TMVR). This procedure leads to an elongation of LVOT in the left ventricle (namely, the neoLVOT), ultimately portending hemodynamic impairment and death. This study sought to understand the biomechanical implications of LVOT obstruction in two patients who underwent TMVR as an "off-label" application of the Edwards SAPIEN 3 (S3) Ultra transcatheter heart valve (THV). A computational framework of TMVR was developed to assess the neoLVOT area and quantify the sub-aortic flow structure. We observed that the annuloplasty ring serves as the key anchor zone of S3 Ultra THV. A good…
Computerized analysis of normal fetal heart rate pattern throughout gestation.
2009
Objective To analyze the evolution of computerized cardiotocography (cCTG) parameters throughout gestation in a large archive of traces from healthy fetuses. Methods This was a cross-sectional study of the first cCTG record from 4412 singleton fetuses with good pregnancy outcome. Normal ranges of cCTG parameters for 25 to 42 weeks were derived from analysis of only one cCTG record per fetus, and the relationship between the parameters and gestational age was investigated. Results Fetal heart rate (FHR) accelerations, short- and long-term variation overall, duration of episodes of high and low variation and variation in high episodes increased with advancing gestation. In contrast, maternal …
Incidence of peripheral intravenous catheter failure and complications in paediatric patients: Systematic review and meta analysis.
2020
Background: Most paediatric patients have at least one peripheral intravenous catheter insertion during their hospitalisation. Despite the important function of peripheral intravenous catheters for delivery of intravenous therapy, failure and complications rates are widely reported; however these results have not been synthesised. Objective: To provide an overall estimate of peripheral intravenous catheter failure and related complications in the paediatric population. Design: Systematic review and meta-analysis Data sources: The electronic databases, Cochrane Central Register of Controlled Trials, US National Library of Medicine National Institutes of Health, Cumulative Index of Nursing an…
A systematic approach to ultrasound-guided central venous catheter placement—desirable modifications
2017
A life-threatening complication of parenteral nutrition: how to prevent cardiac tamponade?
2014
Complications caused by incorrect central venous insertion are numerous. Cardiac tamponade is a rare, but well-documented complication that is often lethal. We present the case of a patient with cardiac tamponade caused by incorrect tip position and infusion of hyperosmolar fluids such as for parenteral nutrition.