Search results for "RM695_Physical"

showing 4 items of 4 documents

Simple Muscle Architecture Analysis (SMA): An ImageJ macro tool to automate measurements in B-mode ultrasound scans

2020

In vivo measurements of muscle architecture (i.e. the spatial arrangement of muscle fascicles) are routinely included in research and clinical settings to monitor muscle structure, function and plasticity. However, in most cases such measurements are performed manually, and more reliable and time-efficient automated methods are either lacking completely, or are inaccessible to those without expertise in image analysis. In this work, we propose an ImageJ script to automate the entire analysis process of muscle architecture in ultrasound images: Simple Muscle Architecture Analysis (SMA). Images are filtered in the spatial and frequency domains with built-in commands and external plugins to hi…

0301 basic medicineMuscle PhysiologyMuscle FunctionsPhysiologyComputer sciencelihaksetDiagnostic RadiologyComputer ArchitectureWorkflowtukikudoksetultrasound imaging0302 clinical medicineSoftwareUltrasound ImagingMedicine and Health SciencesImage Processing Computer-AssistedComputer visionMacroTissues and Organs (q-bio.TO)Musculoskeletal Systemconnective tissueUltrasonographyMultidisciplinaryOrientation (computer vision)Radiology and ImagingMusclesQImage and Video Processing (eess.IV)Gastrocnemius MusclesUltrasoundRultraääniMuscle AnalysisFascicleSMA*Bioassays and Physiological Analysismedicine.anatomical_structureConnective TissueMedicinemuscle analysisAnatomyResearch ArticleComputer and Information SciencesImaging TechniquesScienceFOS: Physical sciencesConnective tissueImage processingmuscle functionsImage Analysisgastrocnemius musclesResearch and Analysis Methods03 medical and health sciencesimage analysisDiagnostic MedicineImage Interpretation Computer-AssistedFOS: Electrical engineering electronic engineering information engineeringmedicineHumanskaksoiskantalihascomputer architectureRM695_Physicalbusiness.industryBiology and Life SciencesQuantitative Biology - Tissues and Organs030229 sport sciencesElectrical Engineering and Systems Science - Image and Video ProcessingPhysics - Medical PhysicsQPimaging techniquesBiological Tissue030104 developmental biologykuva-analyysiFOS: Biological sciencesMedical Physics (physics.med-ph)Artificial intelligenceMuscle architecturebusinessSoftware
researchProduct

Muscle‐tendon morphology and function following long‐term exposure to repeated and strenuous mechanical loading

2019

We mapped structural and functional characteristics of muscle‐tendon units in a population exposed to very long‐term routine overloading. Twenty‐eight military academy cadets (age = 21.00 ± 1.1 years; height = 176.1 ± 4.8 cm; mass = 73.8 ± 7.0 kg) exposed for over 24 months to repetitive overloading were profiled via ultrasonography with a senior subgroup of them (n = 11; age = 21.4 ± 1.0 years; height = 176.5 ± 4.8 cm; mass = 71.4 ± 6.6 kg) also tested while walking and marching on a treadmill. A group of eleven ethnicity‐ and age‐matched civilians (age = 21.6 ± 0.7 years; height = 176.8 ± 4.3 cm; mass = 74.6 ± 5.6 kg) was also profiled and tested. Cadets and civilians exhibited similar mo…

MaleAnatomical structuresPopulationMedial gastrocnemiusPhysical Therapy Sports Therapy and RehabilitationWalking030204 cardiovascular system & hematologyTendonsYoung Adult03 medical and health sciences0302 clinical medicinemedicineHumansOrthopedics and Sports MedicineTreadmillMuscle SkeletaleducationUltrasonographyQMAchilles tendoneducation.field_of_studyRM695_Physicalbusiness.industry030229 sport sciencesAnatomyPatellar tendonBiomechanical PhenomenaTendonMilitary Personnelmedicine.anatomical_structureFascicle lengthbusinessScandinavian Journal of Medicine & Science in Sports
researchProduct

Slower Walking Speed in Older Men Improves Triceps Surae Force Generation Ability

2016

Purpose \ud Older adults walk slower than young adults, but it is not known why. Previous research suggests that ankle plantarflexors may have a crucial role in the reduction of walking speed. The purpose of this study was to investigate age-related differences in triceps surae muscle–tendon function during walking to further investigate the role of plantarflexors in the age-related reduction of walking speed.\ud \ud Methods \ud Medial gastrocnemius and soleus muscle fascicle lengths were measured using ultrasound imaging during walking from 13 young (25 ± 4 yr) men at preferred walking speed and from 13 older (73 ± 5 yr) men at preferred speed and at the young men’s preferred speed. Muscle…

Muscle fascicleAdultMalemedicine.medical_specialtytendonPhysical Therapy Sports Therapy and RehabilitationElectromyographyTendons03 medical and health sciencesYoung Adult0302 clinical medicineTriceps surae musclegastrocnemiusmedicineHumansOrthopedics and Sports MedicineGround reaction forceta315Muscle SkeletalsoleusAgedUltrasonographyfascicleSoleus muscleAged 80 and overRM695_Physicalmedicine.diagnostic_testultrasoundbusiness.industryElectromyographyagingultraääni030229 sport sciencesFascicleQPWalking SpeedPreferred walking speedmedicine.anatomical_structurePhysical therapymedicine.symptombusinesshuman activities030217 neurology & neurosurgeryfascicle tendonMuscle contractionMuscle Contraction
researchProduct

Using deep learning to generate synthetic B-mode musculoskeletal ultrasound images

2020

Background and objective\ud Deep learning approaches are common in image processing, but often rely on supervised learning, which requires a large volume of training images, usually accompanied by hand-crafted labels. As labelled data are often not available, it would be desirable to develop methods that allow such data to be compiled automatically. In this study, we used a Generative Adversarial Network (GAN) to generate realistic B-mode musculoskeletal ultrasound images, and tested the suitability of two automated labelling approaches.\ud \ud Methods\ud We used a model including two GANs each trained to transfer an image from one domain to another. The two inputs were a set of 100 longitu…

RM695_Physicalultrasoundmusclegenerative adversarial networkmedical imagingdeep learningsynthetic imagelihaksetQPQA76koneoppiminenkuvantaminenultraäänitutkimuscycleGAN
researchProduct