Search results for "ROMA"
showing 10 items of 13919 documents
Comparison of silica-based materials for organophosphorus pesticides sampling and occupational risk assessment.
2020
Abstract A novel air sampler has been designed containing a sorbent based on UVM-7 mesoporous silica doped with Ti. The sorbent has been applied for the determination of organophosphorus pesticides in occupational air, followed by gas chromatography with mass spectrometry detection. Thus, several silica materials with different structures (mesoporous UVM-7 and microporous xerogels) were synthesized, and modified with the addition of Ti and Fe. The structure of these materials was proved by transmission electronic microscopy, energy-dispersive X-ray, X-ray diffraction, nitrogen adsorption-desorption and UV–Vis and Raman spectroscopy. The potential of these materials for the retention of pest…
Development of a selective solid phase extraction method for nitro musk compounds in environmental waters using a molecularly imprinted sorbent
2013
A powerful analytical method for the determination of the family of the nitro musk compounds at trace level in environmental waters-river, sea, and water from a treatment plant-is presented. The method is based on the use of molecularly imprinted silica (MIS) as sorbent for solid phase extraction (SPE) used for the clean-up and the concentration step of the target analytes previous to their determination by gas chromatography-mass spectrometry. The optimized extraction procedure allowed extraction recoveries between 61% and 87% using the MIS. The comparison with a non-imprinted silica (NIS) sorbent, for which extraction recoveries between 8% and 26% were obtained, showed the high selectivit…
An investigation of the stability of free and glucuronidated 11-nor-delta9-tetrahydrocannabinol-9-carboxylic acid in authentic urine samples.
2004
Preanalytical stability of a drug and its major metabolites is an important consideration in pharmacokinetic studies or whenever the analyte pattern is used to estimate drug habits. Firstly, the stability of free and glucuronidated 11-nor-delta9-tetrahydrocannabinol-9-carboxylic acid (THCCOOH, THCCOOglu) in authentic urine samples was investigated. Random urine samples of cannabis users (n = 38) were stored at -20, 4, and 20 degrees C up to 15 days and up to 5 days at 40 degrees C, and alterations of the analyte pattern during storage were followed by liquid chromatography-tandem mass spectrometry. Secondly, the influence of pH (range 5.0-8.0) on the stability of the analytes was studied us…
Observation of interaction forces by investigation of the influence of eluent additives on the retention behavior of aqueous nanoparticle dispersions…
2020
The investigation and subsequent understanding of the interactions of nanomaterials with components of their surrounding media is important to be able to evaluate both potential use cases as well as potential risks for human health and for the environment. To investigate such interactions, asymmetrical flow field-flow fractionation (AF4) is an interesting analytical tool. This statement grounds on the fact that interactions of the analyte with the membrane and with components of the eluent are crucial for the retention behavior of the analyte within the field-flow fractionation (FFF) channel. Therefore, the investigation of the retention behavior provides an insight in the nature of the int…
Determination of biochemical parameters in human serum by near-infrared spectroscopy
2014
NIR offers multiple advantages for serum analysis, permitting a fast and direct determination of several parameters simultaneously, with low sample handling and without the need for reagents during the measurement step. The aim of this paper was to provide an evaluation of this technique in a real world scale, for the simultaneous determination of several parameters and based on a considerable number of samples. Direct near infrared (NIR) absorbance measurements were used to determine the concentration of clinical parameters in human serum that are required in routine biochemical tests. Total protein, albumin, total cholesterol, high-density lipoprotein (HDL cholesterol), low-density lipopr…
Wide-range screening of banned veterinary drugs in urine by ultra high liquid chromatography coupled to high-resolution mass spectrometry
2012
In this work, an ultra high performance liquid chromatography-high resolution mass spectrometry (UHPLC-HRMS) methodology is proposed for the multi-class multi-residue screening of banned and unauthorized veterinary drugs in bovine urine, using an Orbitrap Exactive™ analyzer working at a resolving power of 50,000 FWHM in full scan, both in positive and negative mode. The method currently covers 87 analytes belonging to different families such as steroid hormones, β-agonists, resorcylic acid lactones (RAL), stilbens, tranquillizers, nitroimidazoles, corticosteroids, NSAIDs, amphenicoles, thyreostatics and other substances such as dapsone. A database including the elemental composition, the po…
Rapid assay of resveratrol in red wine by paper spray tandem mass spectrometry and isotope dilution.
2017
A rapid analytical approach for the assay of resveratrol in red wines, based on Paper Spray Mass Spectrometry (PS-MS) and Multiple Reaction Monitoring (MRM) is described. The assay involves the use of the stable isotope dilution method. The analytical parameters calculated analyzing fortified samples confirm the reliability of the proposed approach, with accuracy values about 100%, and LOD and LOQ values calculated at 0.5 and 0.8 μg/mL, respectively. Furthermore, both the recovery, which was quantitative for the analyte, and the reproducibility (RSD%), checked on different days on the same wine, always below 7%, highlighted the consistency of the methodology.
Immuno-SLM—a combined sample handling and analytical technique
2004
Immuno-supported liquid membrane (immuno-SLM) extraction is a new technique that makes use of antibody (Ab)-antigen interactions as the "extraction force" to drive the mass transfer in a selective way. In immuno-SLM, anti-analyte (Ag) Abs are introduced into the acceptor phase of the SLM unit to trap the Ag that passes from the flowing donor through the SLM into the stagnant acceptor. The amount of immuno-extracted analyte (AbAg) is quantified by connecting the immuno-SLM unit on-line with a non-competitive heterogeneous fluorescence flow immunoassay (FFIA) that makes use of a fluorescein-labeled analyte tracer that titrates the residual excess of Ab present in the acceptor. A restricted ac…
Data for: Analytical induced force solution in conducting cylindrical bodies and rings due to a rotating finite permanent magnet
2019
Implementation of analytical current density solution in numerical calculations using Wolfram Mathematica software. THIS DATASET IS ARCHIVED AT DANS/EASY, BUT NOT ACCESSIBLE HERE. TO VIEW A LIST OF FILES AND ACCESS THE FILES IN THIS DATASET CLICK ON THE DOI-LINK ABOVE
Comparison of the solid-phase extraction efficiency of a bounded and an included cyclodextrin-silica microporous composite for polycyclic aromatic hy…
2016
Solid-phase extraction is one of the most important techniques for sample purification and concentration. A wide variety of solid phases have been used for sample preparation over time. In this work, the efficiency of a new kind of solid-phase extraction adsorbent, which is a microporous material made from modified cyclodextrin bounded to a silica network, is evaluated through an analytical method which combines solid-phase extraction with high-performance liquid chromatography to determine polycyclic aromatic hydrocarbons in water samples. Several parameters that affected the analytes recovery, such as the amount of solid phase, the nature and volume of the eluent or the sample volume and …