Search results for "ROS"
showing 10 items of 59694 documents
Luminescence of polymorphous SiO2
2016
Abstract The luminescence of self-trapped exciton (STE) was found and systematically studied in tetrahedron structured silica crystals (α-quartz, coesite, cristobalite) and glass. In octahedron structured stishovite only host material defect luminescence was observed. It strongly resembles luminescence of oxygen deficient silica glass and γ or neutron irradiated α-quartz. The energetic yield of STE luminescence for α-quartz and coesite is about 20% of absorbed energy and about 5(7)% for cristobalite. Two types of STE were found in α-quartz. Two overlapping bands of STEs are located at 2.5–2.7 eV. The model of STE is proposed as Si–O bond rupture, relaxation of created non-bridging oxygen (N…
Aqueous Corrosion of the GeSe4 Chalcogenide Glass: Surface Properties and Corrosion Mechanism
2009
International audience; The aqueous corrosion behavior of the GeSe4 glass composition has been studied over time under various conditions (temperature and pH). The evolution of the surface topography by atomic force microscopy and properties such as surface hardness and reduced modulus, as well as the optical transmission in the 1-16 μm window, have been measured as a function of time spent in the corrosive solution. It was found that even if the glass reacts at room temperature, its optical transparency was barely affected. Nevertheless, the durability of GeSe4 was found to be drastically affected by an increase of both temperature and pH. Furthermore, pure selenium nanoparticles were form…
Microfabricated high temperature sensing platform dedicated to scanning thermal microscopy (SThM)
2018
Abstract The monitoring of heat flux is becoming more and more critical for many materials and structures approaching nanometric dimensions. Scanning Thermal Microscopy (SThM) is one of the tools available for thermal measurement at the nanoscale and requires calibration. Here we report on a micro-hotplate device made of a platinum heater suspended on thin silicon nitride (SiN) membranes integrating specific features for SThM calibration. These heated reference samples can include a localized resistive temperature sensors (RTD) or standalone platinum membranes (typically 10 × 10 μm2) on which the temperature can be measured precisely. This functional area is dedicated to (1) estimate the th…
Development of hard x-ray photoelectron SPLEED-based spectrometer applicable for probing of buried magnetic layer valence states
2016
Abstract A novel design of high-voltage compatible polarimeter for spin-resolved hard X-ray photoelectron spectroscopy (Spin-HAXPES) went into operation at beamline BL09XU of SPring-8 in Hyogo, Japan. The detector is based on the well-established principle of electron diffraction from a W(001) single-crystal at a scattering energy of 103.5 eV. It's special feature is that it can be operated at a high negative bias potential up to 10 kV, necessary to access the HAXPES range. The polarimeter is operated behind a large hemispherical analyzer (Scienta R-4000). It was optimized for high transmission of the transfer optics. A delay-line detector (20 mm dia.) is positioned at the exit plane of the…
Synthesis of Eu<sup>2+</sup> and Dy<sup>3+</sup> Doped Strontium Aluminates and their Properties
2016
Strontium aluminate phosphors were synthesized by the solution combustion method using citric acid, urea or glycine as reducing agent and europium and dysprosium as dopants. The content of both dopants was in the range of 1 – 2 mol%. Dependence of phase composition, crystallite size and specific surface area on calcinations temperature, used reducing agents and dopants were determined. Luminescent properties of the calcinated at 1300 °C powders contained SrAl2O4 (90 %) and Sr4Al24O25 (10%) phases with crystallite size of 80 nm were determined.
Simplified feedback control system for scanning tunneling microscopy
2021
A Scanning Tunneling Microscope (STM) is one of the most important scanning probe tools available to study and manipulate matter at the nanoscale. In a STM, a tip is scanned on top of a surface with a separation of a few \AA. Often, the tunneling current between tip and sample is maintained constant by modifying the distance between the tip apex and the surface through a feedback mechanism acting on a piezoelectric transducer. This produces very detailed images of the electronic properties of the surface. The feedback mechanism is nearly always made using a digital processing circuit separate from the user computer. Here we discuss another approach, using a computer and data acquisition thr…
Broadband Ultrahigh-Resolution Spectroscopy of Particle-Induced X Rays: Extending the Limits of Nondestructive Analysis
2016
Nondestructive analysis (NDA) based on x-ray emission is widely used, for example, in the semiconductor and concrete industries. Here, we demonstrate significant quantitative and qualitative improvements in broadband x-ray NDA by combining particle-induced emission with detection based on superconducting microcalorimeter arrays. We show that the technique offers great promise in the elemental analysis of thin-film and bulk samples, especially in the difficult cases where tens of different elements with nearly overlapping emission lines have to be identified down to trace concentrations. We demonstrate the efficiency and resolving capabilities by spectroscopy of several complex multielement …
Effect of surface disorder on the domain structure of PLZT ceramics
2017
ABSTRACTPb1-xLax(Zr0.65Ti0.35)1-x/4O3 (PLZT x/65/35) ceramics were studied by Piezoresponse Force Microscopy in order to understand the origin of domain structure as a function of La content. We show that the domain topology is mainly determined by the composition and grain size. The characteristic correlation length decreases with increasing La content, being sensitive also to the synthesis method. The behavior of the correlation length is linked to the macroscopic properties, showing a strong increase of disorder with La doping. The roughness exponent for the domain wall in PLZT 9/65/35 is close to 2/3 indicating 1D character of domain walls in relaxors.
Optical studies of MBE-grown InN nanocolumns: Evidence of surface electron accumulation
2009
Finite element analysis of stress concentration between surface coated implants and non surface coated implants - An in vitro study.
2019
Background To determine qualitative comparison in stress distribution between surface coated implants and non surface coated implants using 2 different lengths and vertical, oblique, and lateral forces. Material and Methods 3 dimensional finite element study was carried out at first molar site with 4 surface coated and 4 non surface coated implants using mimic 8.11, solid edge 2004, hypermesh 9.0, and ansys12.1 software. Results The pattern of stress distribution was almost similar between vertical and oblique loading but varied with lateral loads between surface coated and non surface coated implants. As the length of the implants increased stress concentration had no significant variation…