Search results for "Radiation"
showing 10 items of 5298 documents
CT evaluation of the renal donor and recipient
2018
Proper pre- and post-transplant diagnostic imaging work-up is fundamental in ensuring a successful outcome for renal transplantation. Despite exposure to ionizing radiation, CT has high spatial resolution and is a widely available and fast imaging technique. CT is performed routinely to delineate the anatomy of the kidney, relevant vasculature, and urinary collecting system in the living donor, to assess the iliac vessels in potential recipients prior to surgery, and to assess early and late-term post-transplant complications. The purpose of this article is to outline the optimal CT protocol and the main reportable findings for both the donor and the recipient diagnostic imaging work-up as …
Uncertainty on radiation doses estimated by biological and retrospective physical methods
2018
International audience; Biological and physical retrospective dosimetry are recognised as key techniques to provide individual estimates of dose following unplanned exposures to ionising radiation. Whilst there has been a relatively large amount of recent development in the biological and physical procedures, development of statistical analysis techniques has failed to keep pace. The aim of this paper is to review the current state of the art in uncertainty analysis techniques across the 'EURADOS Working Group 10- Retrospective dosimetry' members, to give concrete examples of implementation of the techniques recommended in the international standards, and to further promote the use of Monte…
Jaw in a day: Osseointegration of the implants in the patient’s leg before reconstructive surgery of a maxilla with ameloblastoma. A 4-year follow-up…
2021
Background To describe a clinical case of a cancer patient who underwent ablative tumor surgery, including treatment planning, surgical resection and subsequent implant rehabilitation. Case report A 61-year-old patient with a diagnosis of multicystic follicular ameloblastoma in the maxilla, in which it was necessary a multidisciplinary approach and two surgical steps. In the first surgical intervention osseointegrated implants (OII) were placed in the fibula, until their osseointegration period of 8 weeks was complete. Afterwards, in the second surgery, the micro-vascularized free fibular flap bearing the implants was transplanted into the oral cavity, in order to perform simultaneous recon…
Iatrogenic salivary duct injury in head and neck cancer patients: Report of four cases and review of the literature.
2013
Introduction: The lesions of the salivary ducts may be idiopathic, post- traumatic, or iatrogenic and lead to sialocele formation with persistent painful facial swelling or cutaneous fistula formation. No consensus on treatment of this condition exists: the options of treatment include needle aspiration, pressure dressings, antisialogogue therapy, radiotherapy, botulinum toxin and surgical approaches as duct repair, diversion, ligation, different drainage systems and even parotidectomy/submaxilectomy. The management and special features of iatrogenic salivary duct injury in patients with oral cancer who underwent head and neck reconstructive surgery has not been described yet. Material and …
Analysis of cardiac and pulmonary complication probabilities after radiation therapy for patients with early-stage breast cancer
2009
Objective. The purpose of this study was to evaluate the radiobiological implications of clinical use of respiratory-gated techniques for postoperative radiation therapy of early-stage left-sided breast cancer after breast-conserving surgery. Material and methods. Radiation therapy treatment plans of 80 patients with early-stage breast cancer (stage I–II), receiving whole breast irradiation after breast-conserving therapy, were analyzed. The control group consisting of 47 patients received standard radiation therapy, and the respiratory-gated group consisting of 33 patients received deep inspiration-gated radiation therapy. Normal tissue complication probabilities (NTCP) for cardiac mortali…
Editorial from guest editors current Euratom legislation (DE 59/2013): new patient management in radiation protection.
2019
none
S2k guidelines for Merkel cell carcinoma (MCC, neuroendocrine carcinoma of the skin) – update 2018
2019
Merkel cell carcinoma (MCC, ICD-O M8247 / 3) is a rare malignant primary skin tumor with epithelial and neuroendocrine differentiation. The neoplastic cells share many morphological, immunohistochemical and ultrastructural characteristics with Merkel cells of the skin. The diagnosis of MCC is rarely made on clinical grounds. Histological and immunohistochemical studies are usually required to confirm the clinical suspicion. Given the frequent occurrence of occult lymph node metastasis, sentinel lymph node biopsy should be performed once distant metastasis has been ruled out by cross-sectional imaging. Primary tumors without evidence of organ metastases are treated with complete surgical exc…
Radiation effects on light scattering and cataract formation in the lenses of interventional radiologist and cardiologists
2014
Purpose There is little information about exposure to dosages below 500 mSv. This pilot study aimed at investigating the effects of low dose radiation on lens transparency in occupationally exposed interventional cardiologists and radiologists. Methods Physicians who have performed fluoroscopically guided procedures for at least 5 years were recruited in the areas of Cologne-Bonn and Rhine-Main together with their non-exposed colleagues. A questionnaire has been developed to estimate occupational exposure. Exclusion criteria comprised corticosteroid treatment, radiotherapy, chemotherapy and glaucoma. Changes in lens transparency and cataract formation were determined by slit lamp microscopy…
EPR dosimetry intercomparison using smart phone touch screen glass
2014
International audience; This paper presents the results of an interlaboratory comparison of retrospective dosimetry using the electron paramagnetic resonance method. The test material used in this exercise was glass coming from the touch screens of smart phones that might be used as fortuitous dosimeters in a large-scale radiological incident. There were 13 participants to whom samples were dispatched, and 11 laboratories reported results. The participants received five calibration samples (0, 0.8, 2, 4, and 10 Gy) and four blindly irradiated samples (0, 0.9, 1.3, and 3.3 Gy). Participants were divided into two groups: for group A (formed by three participants), samples came from a homogene…
A new resonant Laser-SNMS system for environmental ultra-trace analysis: Installation and optimization
2017
Abstract Localization, analysis and mobility of radioactive contaminated particles is of major concern for assessment of contamination threads and nuclear forensics. For this purpose, a new resonant Laser-SNMS system was developed and set up at the Institute for Radioecology and Radiation Protection for spatially resolved ultra-trace analysis of low concentrated radionuclides directly on environmental samples. This paper describes the adaption and combination of a dedicated Ti:sapphire laser system with a commercial TOF-SIMS instrument for resonant Laser-SNMS. The project includes computer simulations for optimization of the TOF analyzer. Results on synthetic uranium and technetium samples …