Search results for "Radio"

showing 10 items of 8895 documents

Retrograde recanalization of an in-stent ostial chronically occluded right coronary artery

2010

We describe a case of a chronic proximal in-stent CTO extending up to the ostium of a right coronary artery where successful achievement of guidewire passage through the CTO was performed with a retrograde approach. Guidewire trapping into the right guiding catheter was performed thereafter and procedure was completed by retrograde balloon crossing and antegrade stenting. © 2009 Elsevier Ireland Ltd.

medicine.medical_specialtySurgical approachbusiness.industrymedicine.medical_treatmentStentPCIequipment and suppliesBalloonRetrograde approach.SurgeryCTOOstiumsurgical procedures operativeRight coronary arterymedicine.arteryConventional PCIRetrograde approachGuiding catheterMedicinecardiovascular diseasesRadiologyCardiology and Cardiovascular MedicinebusinessInternational Journal of Cardiology
researchProduct

Choice of the operative approach in two cardiosurgical patients assisted by preoperative computed tomography: Case Report

1988

The perioperative course of two patients is exemplified to demonstrate the significance of the preoperative thoracic computed tomography for the selection of a proper surgical approach.

medicine.medical_specialtySurgical approachmedicine.diagnostic_testThoracic computed tomographybusiness.industryComputed tomographyPerioperativeMiddle AgedAortic AneurysmCardiac surgerySurgeryThoracotomyPreoperative CareMyocardial RevascularizationmedicineHumansFemaleRadiologyTomography X-Ray ComputedCardiology and Cardiovascular MedicinebusinessAortaScandinavian Journal of Thoracic and Cardiovascular Surgery
researchProduct

Computed Tomography in Nonneoplastic Space-Occupying Intracranial Lesions

1981

A number of nonneoplastic intracranial space-occupying lesions may resemble neoplasms in the CT scan, and definitive diagnosis is not possible with CT studies alone in many cases. Misinterpretations are possible, even when all clinical data are considered in the interpretation of the CT scan. However, the most accurate possiblepreoperative diagnosis is a prerequisite for decisions on therapeutic strategy and surgical approach. Therefore some cases may require the full range of conventional neuroradiological techniques and careful consideration of clinical findings for correct interpretation of the CT scan with its consequences for therapy. Table 6 summarizes the most common alternatives in …

medicine.medical_specialtySurgical approachmedicine.diagnostic_testbusiness.industryComputed tomographyDiseasemedicine.diseaseArachnoid cystMedicineIntracranial lesionsRadiologyDifferential diagnosisbusinessBrain abscessTherapeutic strategy
researchProduct

Detection of benign hilar bile duct stenoses – A retrospective analysis in 250 patients with suspicion of Klatskin tumour

2016

Introduction The aim of this study was to identify clinical, laboratory and radiological parameters to distinguish benign from malignant stenoses of the proximal bile duct. Methods Between 1997 and 2011, 250 patients were referred to our clinic with hilar bile duct stenoses suspicious for Klatskin tumour. Medical histories, clinical data, pre-interventional laboratory tests, imaging findings, as well as therapeutic approach and patient outcome were compared to final histological results. All data were retrieved from our prospectively maintained database and analysed retrospectively. Results We found benign bile duct lesions in 34 patients (13.6%). Among the entire study population, uni- and…

medicine.medical_specialtySurgical procedureBile ductbusiness.industryGeneral MedicineKlatskin tumourMimicking lesions03 medical and health sciences0302 clinical medicinemedicine.anatomical_structure030220 oncology & carcinogenesisRadiological weaponmedicineRetrospective analysisBenign hilar stenosis030211 gastroenterology & hepatologySurgeryRadiologyDiagnosticbusinessOriginal ResearchAnnals of Medicine and Surgery
researchProduct

Can chemotherapy concomitantly delivered with radiotherapy improve survival of patients with resectable rectal cancer? A meta-analysis of literature …

2010

Summary Background There is clear evidence from two systematic reviews that radiotherapy (RT) reduces the risk of local recurrence in patients with resectable rectal cancer, though the data on survival are still equivocal. Objective To assess the effects of chemotherapy combined concomitantly with radiotherapy (CRT) on the increase of overall survival, and on the prevention of local recurrence and distant metastases. Data sources Computerized bibliographic searches of MEDLINE and CANCERLIT (1970–2008) were supplemented with hand searches of reference lists. Study selection Studies were included if they were randomized controlled trials (RCTs) comparing preoperative or postoperative CRT to p…

medicine.medical_specialtySurvivalColorectal cancermedicine.medical_treatmentPopulationAntineoplastic Agentslaw.inventionRectal carcinomaRandomized controlled triallawRisk of mortalityHumansMedicineMeta-analysiRadiology Nuclear Medicine and imagingNeoplasm Metastasiseducationeducation.field_of_studyRadiotherapyRectal Neoplasmsbusiness.industryChemoradiotherapyGeneral Medicinemedicine.diseaseCombined Modality TherapySurgeryRadiation therapyOncologyConcomitantMeta-analysisbusinessPublication BiasChemoradiotherapyCancer Treatment Reviews
researchProduct

The impact of radiotherapy on survival in resectable gastric carcinoma: A meta-analysis of literature data.

2007

Summary Background The benefit of external radiotherapy for gastric carcinoma has been extensively studied, but data on survival are still equivocal. Objective To assess the effectiveness of surgery combined with preoperative radiotherapy or postoperative chemoradiotherapy in the reduction of all-cause mortality in patients with resectable gastric carcinoma. Methods Computerised bibliographic searches of MEDLINE and CANCERLIT (1970–2006) were supplemented with hand searches of reference lists. Study selection Studies were included if they were randomised controlled trials (RCTs) comparing mortality of surgery combined with preoperative radiotherapy or postoperative chemoradiotherapy to surg…

medicine.medical_specialtySurvivalmedicine.medical_treatmentGastric carcinoma; Meta-analysis; Radiotherapy; SurvivalMEDLINElaw.inventionRandomized controlled triallawStomach NeoplasmsGastric carcinoma; Meta-analysis; Radiotherapy; Survival;medicineCombined Modality TherapyHumansRadiology Nuclear Medicine and imagingMeta-analysiRandomized Controlled Trials as TopicIntention-to-treat analysisRadiotherapybusiness.industryMortality rateGastric carcinomaGeneral MedicineCombined Modality TherapySurgeryRadiation therapyOncologyMeta-analysisRadiotherapy AdjuvantbusinessChemoradiotherapy
researchProduct

A regenerative 3D scaffold for inguinal hernia repair. MR imaging and histological cross evidence. Qualitative study

2021

Abstract Background Inguinal hernia is a degenerative disease occurring in a high motile surround. Stopping degeneration and promoting tissue regeneration should be the treatment goal. Groin hernias are conventionally managed with static flat meshes, mostly fixated to the delicate inguinal environment. Far from a regenerative effect, the biologic response of conventional hernia meshes is characterized by a foreign body reaction leading to a stiff/shrunken scar plate, which is often the source of unpleasant complications. Recently, a newly engineered 3D device for inguinal hernia repair – ProFlor-has been developed to produce a regenerative biological response. Unlike conventional hernia mes…

medicine.medical_specialtySwineAdipose tissueHernia InguinalGroinProsthesesDegenerative diseaseMagnetic resonance imagingmedicineAnimalsHerniaHerniorrhaphymedicine.diagnostic_testGroinbusiness.industryInguinal herniaMagnetic resonance imagingHistologyGeneral MedicineSurgical Meshmedicine.diseaseInguinal herniamedicine.anatomical_structureHernia genesisPorcine experimental modelSurgeryRadiologyForeign bodybusinessRegenerative scaffolds
researchProduct

Plain film, CT and MRI sensibility in the evaluation of intraorbital foreign bodies in an in vitro model of the orbit and in pig eyes.

2000

Detection and characterization of intraorbital foreign bodies (IFB) is fundamental in acute trauma setting, preventing inflammatory sequelae or complications related to IFB movements when a MRI study is planned. Papers concerning plain film and CT sensibility in IFB detection show controversial results. For this reason we investigated plain film, CT and MRI sensibility in the evaluation of IFB. For an in vitro model, specimens of dry and fresh wood, glass, iron, plastic and graphite were immersed in animal lard and in a 0.9 % sodium chloride plus 3.5 g/dl human serum albumin solution. Specimens of different size and nature where also implanted into enucleated pig eyes. Air bubbles were intr…

medicine.medical_specialtySwineRadiodensityRadiographyPlain filmEyeSensitivity and SpecificityIn vitro modelmedicineAnimalsHumansRadiology Nuclear Medicine and imagingmedicine.diagnostic_testbusiness.industryUltrasoundMagnetic resonance imagingGeneral MedicineMagnetic Resonance ImagingEye Injuries Penetratingmedicine.anatomical_structureEye Foreign BodiesTomographyRadiologybusinessTomography X-Ray ComputedOrbitOrbit (anatomy)European radiology
researchProduct

In vitro comparison of platinum-iridium and gold tip electrodes: lesion depth in 4 mm, 8 mm, and irrigated-tip radiofrequency ablation catheters

2009

Aims We compared a newly developed irrigated gold tip electrode ablation catheter and a gold tip 4 and 8 mm catheter with the corresponding platinum–iridium (Pt) tip catheters in an in vitro setting. Methods and results In a flow chamber simulating physiological flow conditions, radiofrequency catheter ablation was performed on tissue samples of porcine endomyocardium and liver. Lesion depth, energy and temperature delivery, and popping frequency were determined. Two hundred and fifty-three ablations were conducted. Four and eight millimetre, gold tip electrode catheters produced significantly deeper lesions compared with the Pt tip electrode (liver 4 mm: 4.67 ± 1.7 vs. 2.9 ± 1.0 mm, P < 0.…

medicine.medical_specialtySwineRadiofrequency ablationmedicine.medical_treatmentchemistry.chemical_elementIn Vitro TechniquesIridiumlaw.inventionlawPhysiology (medical)medicineAnimalsIridiumCardiac Surgical ProceduresElectrodesPlatinumbusiness.industryLesion depthAblationSurgeryCatheterLiverchemistryRadiofrequency catheter ablationModels AnimalElectrodeCatheter AblationGoldCardiology and Cardiovascular MedicinePlatinumbusinessNuclear medicineEuropace
researchProduct

Imaging of Ventriculoperitoneal Shunt Complications: Comparison of Whole Body Low-Dose Computed Tomography and Radiographic Shunt Series.

2016

OBJECTIVE To determine diagnostic value and radiation exposure of low-dose computed tomography (LD-CT) compared to radiographic shunt series (SS) for the detection of ventriculoperitoneal (VP) shunt complications. METHODS Fourteen VP shunts were implanted in 7 swine cadavers. Mechanical complications were induced in 50% of VP shunts. Low-dose CT (80 kVp, 10 mAs, Pitch = 1.5) and SS were acquired. Dose area product (DAP) and effective doses for SS and LD-CT were collected. Scoring of diagnostic confidence and blinded readings of SS and CT data were performed. RESULTS The sensitivity of LD-CT was high (0.97; 95% confidence interval, 0.91-1.00) with excellent interobserver agreement (κ = 0.88)…

medicine.medical_specialtySwineRadiographyComputed tomographyRadiation DosageEffective dose (radiation)Sensitivity and SpecificityVentriculoperitoneal Shunt030218 nuclear medicine & medical imaging03 medical and health sciences0302 clinical medicinePostoperative ComplicationsRadiation ProtectionmedicineAnimalsRadiology Nuclear Medicine and imagingMedical physicsSingle-Blind MethodWhole Body Imagingmedicine.diagnostic_testbusiness.industryLow doseReproducibility of ResultsRadiation ExposureConfidence intervalRadiographic Image EnhancementDose area productRadiographic Image Interpretation Computer-AssistedTomographybusinessNuclear medicineTomography X-Ray Computed030217 neurology & neurosurgeryShunt (electrical)Journal of computer assisted tomography
researchProduct