Search results for "Radiofrequency"
showing 10 items of 94 documents
Novel Application of Pulsed Radiofrequency Energy Device (PEAK Plasmablade) in Neurosurgical Reconstructive Surgery.
2018
In vitro comparison of platinum-iridium and gold tip electrodes: lesion depth in 4 mm, 8 mm, and irrigated-tip radiofrequency ablation catheters
2009
Aims We compared a newly developed irrigated gold tip electrode ablation catheter and a gold tip 4 and 8 mm catheter with the corresponding platinum–iridium (Pt) tip catheters in an in vitro setting. Methods and results In a flow chamber simulating physiological flow conditions, radiofrequency catheter ablation was performed on tissue samples of porcine endomyocardium and liver. Lesion depth, energy and temperature delivery, and popping frequency were determined. Two hundred and fifty-three ablations were conducted. Four and eight millimetre, gold tip electrode catheters produced significantly deeper lesions compared with the Pt tip electrode (liver 4 mm: 4.67 ± 1.7 vs. 2.9 ± 1.0 mm, P < 0.…
Pulsed radiofrequency energy device (PEAK plasmablade™) and CustomBone® Cranioplasty: an appealing surgical rendez-vous
2019
Background: CustomBone® prosthesis is a widely recognized effective and successful technique for the reconstruction of cranial bone defects. Prior the cranioplasty implant, meticulous dissection wi...
Interventional treatment for neuropathic pain due to combined cervical radiculopathy and carpal tunnel syndrome: a case report
2017
Key Clinical Message The coexistence of median and cervical nerve root damage might hide a complex pathophysiology. Here, we describe and discuss the case of a patient suffering from numbness and painful tingling of the hand, whose symptoms were effectively treated with pulsed radiofrequency and epidural administration of bupivacaine and morphine.
Long-Term Efficacy of Radiofrequency Treatment of Turbinate Hypertrophy: A Patient Based Point of View
2010
Nasal turbinate hypertrophy is a major cause of nasal airway obstruction that affects up to 20% of the European general population. This study aims to determine the efficacy of radiofrequency treatment as perceived by patients during a 2-years period. From 2007 to 2009, an observational study was conducted on 36 patients who consecutively underwent temperature-controlled radiofrequency tissue volume reduction. A questionnaire was administered to each patient in order to collect demographic data, lifestyle habits, health status and visual analogue scale (VAS) score of perceived symptoms. Mean VAS scores of nasal obstruction, headache, rhinorrhoea and anosmia after treatment were significantl…
Minimally invasive techniques in the treatment of saphenous varicose veins.
2008
Lower extremity venous insufficiency is common and increases with age. In addition to classical symptoms, it may result in skin changes and venous ulcers. Chronic venous insufficiency has a great impact on patients' health-related quality of life and is associated with considerable health care costs. Surgical ligation Of the junction with or without stripping has been the standard of care in the treatment of insufficient great and small saphenous veins. However, the recurrence rates are relatively high and surgery may be associated with serious adverse events and considerable down time; it is also cosmetically Suboptimal. To improve efficacy, patients' health-related quality of life and tre…
Treatment decision making in patients with arrhythmogenic right ventricular dysplasia/cardiomyopathy: State of the art
2014
No abstract available
Does the origin of ablated premature ventricular contractions determine the level of left ventricular function improvement?
2020
Background: Premature ventricular contractions (PVCs) are associated with tachycardiomyopathy and high mortality rate. The treatment depends on the engaged ventricle. For PVCs originating from the right outflow tract (OT), radiofrequency catheter ablation (RFCA) is recommended (class IB‑R recommendation) in preference to pharmacotherapy. In those originating from the left ventricle, ablation is a class IIa B‑NR recommendation. Aims: The aim of the study was to assess the success of RFCA of PVCs based on arrhythmia origin. Methods: A total of 110 consecutive patients with monomorphic PVCs referred for ablation were enrolled and divided according to the site of ablation to the OT group and th…
THE APPLICATION OF NEEDLE RADIOFREQUENCY FOR THE REDUCTION OF ACNE SCARS: A CASE STUDY.
2019
Background: Acne fulminans can leaveunsightly scars that can have a detrimental effect on a person’s ability to function in society, resulting in a deterioration in the overall quality of life of these patients. Scientific research shows that problems with self-esteemmay lower a person’s quality of life, making them reluctant to interact with other people.This, in turn, may lead to depression and, in extreme cases, to suicide. For people who suffer from acne fulminans, this is an extremely serious problem.This is compounded by the fact that even if they spend much of their life fighting acne, ultimately successfully, they still may be left with the visual effects of the disease, like scars.…
Electrocatheter-mediated High-voltage Pulsed Radiofrequency of the Dorsal Root Ganglion in the Treatment of Chronic Lumbosacral Neuropathic Pain
2019
Objectives: Despite the interest in scientific community, there is still poor evidence about pulsed radiofrequency (PRF) efficacy in the treatment of neuropathic pain. In order to determine whether high-voltage PRF and epidural adhesiolysis (PRF-EA) showed better results than epidural adhesiolysis alone (EA), a randomized, double-blind, comparative-effectiveness study was conducted in patients with chronic lumbosacral radiating pain and neuropathic features. Materials and Methods: A total of 41 patients were randomly allocated to 2 groups. Twenty-one patients were randomized to receive 2 cycles of 240 seconds high-voltage PRF followed by the injection of local anesthetics, hyaluronidase, an…