Search results for "Radiographic image interpretation"
showing 10 items of 44 documents
Three-Dimensional Analysis of Component Stability of the Nellix Endovascular Aneurysm Sealing System After Treatment of Infrarenal Abdominal Aortic A…
2016
Purpose: To assess short-term stability and conformational changes of the Nellix EndoVascular Aneurysm Sealing (EVAS) System using 3-dimensional (3D) analysis. Methods: Postoperative computed tomography (CT) scans obtained at 0, 3, and 12 months in 24 patients (mean age 75±7 years; 22 men) who underwent EVAS between December 2013 and December 2014 for intact abdominal aortic aneurysm (within the instructions for use) were evaluated for stent-graft deviation in multiple planes using dedicated 3D analysis software. In addition, 2D analysis using an anatomically fixed reference landmark was performed to assess craniocaudal migration. Clinical and follow-up data of the patients were recorded a…
MDCT and virtual angioscopy in spontaneous aortocaval fistula
2007
Aortocaval fistula is a rare, less than 1%, but life threatening complication, of abdominal aortic aneurysm. Mortality is high but prompt recognition of the fistula can reduce mortality rate. The multidetector row CT (MDCT) findings in a 69-year-old patient with a complex medical history characterized by previous episodes of myocardial ischemia, is reported. MDCT shows an early homogeneous enhancement of the inferior vena cava, slightly dilated at the liver level and markedly narrowed above the renal vein due to aneurysm compression. The patient underwent to emergency laparotomy but died during surgery for cardiac arrest. MDCT allows a prompt recognition of the fistula and different compute…
Tako-tsubo cardiomyopathy and microcirculation.
2010
Takotsubo cardiomyopathy was described for the first time in Japan in the 1990s. It is very similar to the ischemic cardiopathy both for clinical and instrumental characteristics. His peculiarity is an alteration of the ventricular contraction mechanism with hypo-akinesis of the apex and lateral segments of the left ventricle, associated with hyper-kinesis of the heart base which is responsible for the typical echocardiographic aspect of a cruet during the systole. However, the etiology of this cardiomyopathy is still unknown despite the fact that numerous hypothesis have been made. A single study of 16 patients proved multivasal damage by a BLASH SCORE analysis of the coronary radiography.…
Influence of pixel size on quantification of airway wall thickness in computed tomography.
2009
Objectives: The purpose of this study was to determine the point where a further decrease in voxel size does not result in better automatic quantification of the bronchial wall thickness by using 2 different assessment techniques. Materials and Methods: The results from the commonly used full-width-at-half-maximum (FWHM) principle and a new technique (integral-based method [IBM]) were compared for thin-section multidetector computed tomography (MDCT) data sets from an airway phantom containing 10 different tubular airway phantoms and in a human subsegmental bronchus in vivo. Correlation with the actual wall thickness and comparison of the wall thicknesses assessed for different voxel sizes …
Computational analysis to predict false-lumen perfusion and outcome of type B aortic dissection.
2014
We have attempted to identify potential predictors foracute and late aortic events starting from admission computed tomographic images.
Metabolic impact of Partial Volume Correction of [18F]FDG PET-CT oncological studies on the assessment of tumor response to treatment
2014
AIM: The aim of this work is to evaluate the metabolic impact of Partial Volume Correction (PVC) on the measurement of the Standard Uptake Value (SUV) from [18F]FDG PET-CT oncological studies for treatment monitoring purpose. METHODS: Twenty-nine breast cancer patients with bone lesions (42 lesions in total) underwent [18F]FDG PET-CT studies after surgical resection of breast cancer primitives, and before (PET-I) and after (PET-II) chemotherapy and hormone treatment. PVC of bone lesion uptake was performed on the two [18F]FDG PET-CT studies, using a method based on Recovery Coefficients (RC) and on an automatic measurement of lesion metabolic volume. Body-weight average SUV was calculated f…
About Objective 3-D Analysis of Airway Geometry in Computerized Tomography
2008
The technology of multislice X-ray computed tomography (MSCT) provides volume data sets with approximately isotropic resolution, which permits a noninvasive 3-D measurement and quantification of airway geometry. In different diseases, like emphysema, chronic obstructive pulmonary disease (COPD), or cystic fribrosis, changes in lung parenchyma are associated with an increase in airway wall thickness. In this paper, we describe an objective measuring method of the airway geometry in the 3-D space. The limited spatial resolution of clinical CT scanners in comparison to thin structures like airway walls causes difficulties in the measurement of the density and the thickness of these structures.…
3D reconstruction techniques made easy: know-how and pictures
2005
Three-dimensional reconstructions represent a visual-based tool for illustrating the basis of three-dimensional post-processing such as interpolation, ray-casting, segmentation, percentage classification, gradient calculation, shading and illumination. The knowledge of the optimal scanning and reconstruction parameters facilitates the use of three-dimensional reconstruction techniques in clinical practise. The aim of this article is to explain the principles of multidimensional image processing in a pictorial way and the advantages and limitations of the different possibilities of 3D visualisation.
Role of virtopsy in the post-mortem diagnosis of drowning.
2014
Purpose: Due to admitted limits of autopsy-based studies in the diagnosis of drowning, virtopsy is considered the new imaging horizon in these post-mortem studies. The aim of our study was to evaluate the role of virtopsy performed through computed tomography (CT) in the forensic diagnosis of drowning. Materials and methods: We retrospectively examined the CT data of four cadavers recovered from sea water and suspected to have died by drowning. Each patient underwent a full-body post-mortem CT scan, and then a traditional autopsy. Conclusion: To date, there are no autopsy findings pathognomonic of drowning. This study proves that virtopsy is a useful tool in the diagnosis of drowning in tha…
Impact of the Tiloop Bra mesh in CT images and dose delivery in breast radiotherapy
2012
A new titanized breast mesh, TiLOOP Bra, is currently available for implantation in patients who require radiotherapy. The purpose of this work is to study the dosimetric effect of the presence of a TiLOOP Bra mesh on breast radiation treatment and radiographic imaging. The dosimetric effects have been measured for three X‐ray energies: 1.25 MeV, 6 MV and 18 MV, using radiochromic films placed at three different depths. These depths are representative of mesh location in breast during the radiotherapy treatment and hence, are of interest in this study. In order to assess the disturbance in a radiographic image, different computed tomographic (CT) studies of the mesh have been performed. The…