Search results for "Radiographic"

showing 9 items of 99 documents

Misdiagnosis of Thoracolumbar Posterior Ligamentous Complex Injuries and Use of Radiographic Parameter Correlations to Improve Detection Accuracy

2019

Study Design Retrospective study. Purpose To evaluate radiological parameters as indicators for posterior ligamentous complex (PLC) injuries in the case of limited availability of magnetic resonance imaging. Overview of Literature Traumatic thoracolumbar spinal fractures with PLC injuries can be misdiagnosed on X-rays or computed tomography scans. This study aimed to retrospectively assess unrecognized PLC injuries and evaluate radiographic parameters as indicators of PLC injuries requiring surgery. Methods In total, 314 patients with type A and type B2 fractures who underwent surgical treatment between 2001 and 2010 were included. The frequency of misdiagnosis was reassessed, and radiograp…

medicine.medical_specialtyRadiographylcsh:Medicine03 medical and health sciences0302 clinical medicineMedicineOrthopedics and Sports MedicineInterspinous distance030222 orthopedicsmedicine.diagnostic_testCobb anglePosterior ligamentous complex injurybusiness.industrylcsh:RSpine injury classificationMagnetic resonance imagingRetrospective cohort studySagittal planeRadiographic assessmentmedicine.anatomical_structureRadiological weaponOrthopedic surgeryClinical StudySurgeryRadiologybusinessThroacolumbar spinal fracture030217 neurology & neurosurgeryAsian Spine Journal
researchProduct

Imaging of Ventriculoperitoneal Shunt Complications: Comparison of Whole Body Low-Dose Computed Tomography and Radiographic Shunt Series.

2016

OBJECTIVE To determine diagnostic value and radiation exposure of low-dose computed tomography (LD-CT) compared to radiographic shunt series (SS) for the detection of ventriculoperitoneal (VP) shunt complications. METHODS Fourteen VP shunts were implanted in 7 swine cadavers. Mechanical complications were induced in 50% of VP shunts. Low-dose CT (80 kVp, 10 mAs, Pitch = 1.5) and SS were acquired. Dose area product (DAP) and effective doses for SS and LD-CT were collected. Scoring of diagnostic confidence and blinded readings of SS and CT data were performed. RESULTS The sensitivity of LD-CT was high (0.97; 95% confidence interval, 0.91-1.00) with excellent interobserver agreement (κ = 0.88)…

medicine.medical_specialtySwineRadiographyComputed tomographyRadiation DosageEffective dose (radiation)Sensitivity and SpecificityVentriculoperitoneal Shunt030218 nuclear medicine & medical imaging03 medical and health sciences0302 clinical medicinePostoperative ComplicationsRadiation ProtectionmedicineAnimalsRadiology Nuclear Medicine and imagingMedical physicsSingle-Blind MethodWhole Body Imagingmedicine.diagnostic_testbusiness.industryLow doseReproducibility of ResultsRadiation ExposureConfidence intervalRadiographic Image EnhancementDose area productRadiographic Image Interpretation Computer-AssistedTomographybusinessNuclear medicineTomography X-Ray Computed030217 neurology & neurosurgeryShunt (electrical)Journal of computer assisted tomography
researchProduct

Accuracy of automatic airway morphometry in computed tomography-correlation of radiological-pathological findings.

2010

Abstract Objectives Airway morphology shows characteristic changes in different pathologies. This study assesses the accuracy of a current automatic airway assessment technique by correlating CT images of porcine airways to histological slices of the same localization. Materials and methods Four isolated and ventilated porcine lungs were frozen in a liquid nitrogen bath and examined with a CT scanner (MDCT). This technique both preserved normal radiomorphological appearance and made it possible to slice the specimens for histological examination for subsequent correlation. The parameters wall thickness (WT), wall percentage (WP), and total diameter (TD) were assessed by computer-aided measu…

medicine.medical_specialtySwineStatistics as TopicBronchiIn Vitro TechniquesSensitivity and SpecificityImaging phantomPattern Recognition AutomatedCorrelationBronchoscopyMedicineAnimalsRadiology Nuclear Medicine and imagingPathologicalbusiness.industryReproducibility of ResultsHistologyGeneral MedicineTracheaRadiological weaponCalipersRadiographic Image Interpretation Computer-AssistedRadiologyTomographybusinessAirwayNuclear medicineTomography X-Ray ComputedAlgorithmsEuropean journal of radiology
researchProduct

The pharmacological rationale for combining muscarinic receptor antagonists and beta-adrenoceptor agonists in the treatment of airway and bladder dis…

2014

Highlights • Muscarinic receptors increase smooth muscle tone in airways and urinary bladder. • β-Adrenoceptors relax smooth muscle tone and oppose muscarinic contraction. • Opposition involves transmitter release, signal transduction and receptor expression. • This supports the combined use of muscarinic antagonists and β-adrenoceptor agonists.

medicine.medical_specialtyUrologyDiseaseMuscarinic AntagonistsPharmacologyArticleβ adrenoceptorchemistry.chemical_compoundInternal medicineReceptors Adrenergic betaMuscarinic acetylcholine receptorDrug DiscoveryMuscarinic acetylcholine receptor M4RAT URINARY-BLADDERMedicineAnimalsHumansCyclic adenosine monophosphateADRENERGIC RELAXATIONLung Diseases ObstructivePROTEIN-KINASE-CReceptorTRACHEAL SMOOTH-MUSCLEPharmacologybusiness.industryUrinary Bladder DiseasesMuscarinic acetylcholine receptor M3Muscarinic acetylcholine receptor M2ACETYLCHOLINE-RELEASEAdrenergic beta-Agonistsmedicine.diseaseReceptors MuscarinicEndocrinologyNONNEURONAL CHOLINERGIC SYSTEMchemistryGUINEA-PIG TRACHEADrug Therapy CombinationCYCLIC ADENOSINE-MONOPHOSPHATECA2+-ACTIVATED K+ CHANNELAirwaybusinessUrinary bladder diseaseAUTORADIOGRAPHIC VISUALIZATIONAcetylcholinemedicine.drug
researchProduct

The central odontogenic fibroma: How difficult can be making a preliminary diagnosis

2016

Central odontogenic fibroma (COF) is a rare benign odontogenic tumor derived from the dental ectomesenchymal tissues. A 16-year-old Caucasian female patient was referred by her dentist for a radiolucent asymptomatic area associated with the crown of the impacted lower right third molar. A preliminary diagnosis of a follicular cyst was supposed. The lesion was surgically removed under general anesthesia together with the impacted tooth. The microscopic diagnosis of the excised tissue revealed an odontogenic fibroma. No clinical or radiographic signs of recurrence were found five years after surgical excision. Despite the various differential diagnoses of homogeneous unilocular and well delim…

medicine.medical_specialtymedicine.medical_treatmentEnucleationOdontologíaCase ReportAsymptomaticOdontogenic FibromaLesionSettore MED/28 - MALATTIE ODONTOSTOMATOLOGICHE03 medical and health sciences0302 clinical medicinestomatognathic systemdifferential diagnosismedicineCentral odontogenic fibromaodontogenic fibromaGeneral Dentistrydentistry (all)Follicular Cystbusiness.industryImpacted toothradiographic imaging030206 dentistrymedicine.disease:CIENCIAS MÉDICAS [UNESCO]microscopic diagnosisCiencias de la saludCurettageimpacted third molarSurgerystomatognathic diseases030220 oncology & carcinogenesisUNESCO::CIENCIAS MÉDICASdifferential diagnosis; impacted third molar; microscopic diagnosis; odontogenic fibroma; radiographic imaging; dentistry (all)medicine.symptomOral SurgerybusinessJournal of Clinical and Experimental Dentistry
researchProduct

Residual coronary stenosis after thrombolysis with rt-PA or streptokinase: acute results and 3 weeks follow-up

1987

Ninety-one patients with acute myocardial infarction were assigned to intravenous treatment with streptokinase or rt-PA as part of the randomized trial carried out by the European Study Group for Recombinant Tissue-Type Plasminogen Activator (rt-PA). A patent coronary artery was found in 37 of 45 (82%) patients treated with rt-PA and in 27 of 46 (59%) patients treated with streptokinase 75-90 minutes after start of infusion. Patients were subsequently anticoagulated with heparin or dicoumarol up to a repeat angiography 3 weeks after the infarction. Of the 64 patients with successful reperfusion, 3 died and 3 suffered reocclusion of the vessel. Quantitative analysis of the coronary stenosis …

medicine.medical_specialtymedicine.medical_treatmentStreptokinaseInfarctionCoronary DiseaseCoronary AngiographyRandom AllocationReperfusion therapyRecurrenceInternal medicineHumansMedicineStreptokinaseMyocardial infarctionVascular PatencyClinical Trials as Topicmedicine.diagnostic_testbusiness.industryHeparinThrombolysisMiddle Agedmedicine.diseaseRecombinant Proteinsmedicine.anatomical_structureTissue Plasminogen ActivatorAngiographyCardiologyCineangiographyRadiographic Image Interpretation Computer-AssistedCardiology and Cardiovascular MedicinebusinessFollow-Up Studiesmedicine.drugArteryEuropean Heart Journal
researchProduct

The migration of femoral components after total hip replacement surgery: accuracy and precision of software-aided measurements.

2003

To assess the accuracy and precision of a software-aided system to measure migration of femoral components after total hip replacement (THR) on digitised radiographs.Subsidence and varus-valgus tilt of THR stems within the femur were measured on digitised anteroposterior pelvic radiographs. The measuring software (UMA, GEMED, Germany) relies on bony landmarks and comparability parameters of two consecutive radiographs. Its accuracy and precision were calculated by comparing it with the gold standard in migration measurements, radiostereometric analysis (RSA). Radiographs and corresponding RSA measurements were performed in 60 patients (38-69 years) following cementless THR surgery.The UMA s…

musculoskeletal diseasesAdultMaleAccuracy and precisionmedicine.medical_specialtymedicine.medical_treatmentRadiographyArthroplasty Replacement HipProsthesisRadiostereometric AnalysisForeign-Body MigrationmedicineImage Processing Computer-AssistedHumansRadiology Nuclear Medicine and imagingFemurFemurDigital radiographyAgedOrthodonticsReproducibilitybusiness.industryReproducibility of ResultsMiddle Agedmusculoskeletal systemSurgeryProsthesis FailureRadiographic Image EnhancementOrthopedic surgeryFemaleHip ProsthesisbusinessSkeletal radiology
researchProduct

Self-reported flares are predictors of radiographic progression in rheumatoid arthritis patients in 28-joint disease activity score remission: a 24-m…

2016

Background Disease flares are common in rheumatoid arthritis (RA) and are related to structural damage. However, few data on the impact of flares reported by patients on radiographic progression are available. Our aim was to investigate whether overall flares (OF), self-reported flares (SRF) and short flares assessed at the visit (SF) predict radiographic progression in RA patients in DAS28 (28-joint disease activity score) remission. Methods We reviewed the records of RA patients included in our database. We considered all patients who had a period of at least 24 months in remission (DAS28 0. Patients were assessed every 3 months and flares were recorded. We defined SRF as any worsening of…

musculoskeletal diseasesmedicine.medical_specialtyRadiographic progressionRadiographyDiseasenot knownDisease activity03 medical and health sciencesJoint disease0302 clinical medicineInternal medicineDAS28 remissionmedicine030212 general & internal medicineRheumatoid arthritisskin and connective tissue diseases030203 arthritis & rheumatologybusiness.industryFlaresmedicine.diseaseRheumatologyBiologic treatment; DAS28 remission; Flares; Radiographic progression; Rheumatoid arthritis; Self-reported flaresRheumatoid arthritisOrthopedic surgeryPhysical therapyObservational studybusinessBiologic treatmentSelf-reported flaresResearch ArticleArthritis Research & Therapy
researchProduct

Radiographic Assessment of Tibiofibular Syndesmosis Injury with Different Durations and Types of Fixation

2022

Introduction: There is no consensus among orthopedic surgeons on the number of cortical layers (tricortical or quadricortical fixation) involved or the duration of syndesmotic fixation after a tibiofibular syndesmosis (TFSD)-injury treatment. The purpose of this study was to assess radiographic parameters following the treatment of TFSD injuries, with various time-windows of syndesmotic screw removal and numbers of cortical layers involved. Materials and Methods: Fifty-five patients, aged from 25 to 75 years, were included in the study. The follow-up period ranged from 2 years to 4 years and 2 months. The patients were subdivided into groups based on the duration of the syndesmotic fixation…

radiographic; tibiofibular syndesmosis injury; duration; types of fixationGeneral MedicineJournal of Clinical Medicine
researchProduct