Search results for "Radiometer"
showing 10 items of 272 documents
Sun-induced chlorophyll fluorescence II: Review of passive measurement setups, protocols, and their application at the leaf to canopy level
2019
Imaging and non-imaging spectroscopy employed in the field and from aircraft is frequently used to assess biochemical, structural, and functional plant traits, as well as their dynamics in an environmental matrix. With the increasing availability of high-resolution spectroradiometers, it has become feasible to measure fine spectral features, such as those needed to estimate sun-induced chlorophyll fluorescence (F), which is a signal related to the photosynthetic process of plants. The measurement of F requires highly accurate and precise radiance measurements in combination with very sophisticated measurement protocols. Additionally, because F has a highly dynamic nature (compared with othe…
Thermal-Infrared Spectral and Angular Characterization of Crude Oil and Seawater Emissivities for Oil Slick Identification
2014
Previous work has shown that the emissivity of crude oil is lower than that of the seawater in the thermal-infrared (TIR) spectrum. Thus, oil slicks cause an emissivity decrease relative to the seawater in that region. The aim of this paper was to carry out experimental measurements to characterize the spectral and angular variations of crude oil and seawater emissivities. The results showed that the crude oil emissivity is lower than the seawater emissivity and that it is essentially flat in the atmospheric window of 8-13 μm. The crude oil emissivity has a marked emissivity decrease with the angle (from 0.956 ± 0.005 at 15 ° to 0.873 ± 0.007 at 65 °), which is even higher than that of the …
LST retrieval algorithm adapted to the Amazon evergreen forests using MODIS data
2018
Abstract Amazonian tropical forests play a significant role in global water, carbon and energy cycles. Considering the importance of this biome and climate change projections, the monitoring of vegetation status of these rainforests becomes of significant importance. In this context vegetation temperature is presented as a key variable linked with plant physiology. In particular some studies showed the relationship between this variable and the CO2 absorption capacity and biomass loss of these tropical forests proving the potential use of vegetation temperature in the monitoring of the vegetation status. Nevertheless, the use of thermal remote sensing data over tropical forests still has so…
Comparison of field emissivities with laboratory measurements and ASTER data
2008
Surface emissivity in the thermal infrared (TIR) region is an important parameter for determining the land surface temperature from remote sensing measurements. This work compares the emissivities measured by different field methods (the Box method and the Temperature and Emissivity Separation, TES, algorithm) as well as emissivity data from ASTER scenes and the spectra obtained from the ASTER Spectral Library. The study was performed with a field radiometer having TIR bands with central wavelengths at 11.3 μm, 10.6 μm, 9.1 μm, 8.7 μm and 8.4 μm, similar to the ASTER TIR bands. The measurements were made at two sites in southern New Mexico. The first was in the White Sands National Monument…
Comparison of Thermal Infrared Emissivities Retrieved With the Two-Lid Box and the TES Methods With Laboratory Spectra
2009
Knowledge of surface emissivity in the thermal infrared (TIR) region is critical for determining the land surface temperature (LST) from remote-sensing measurements. If emissivity is not well determined, it can cause a significant systematic error in obtaining the LST. The main aim of this paper is to compare different methods for measuring accurate land surface emissivity in the field, namely, the box method and the temperature and emissivity separation (TES) algorithm. Field emissivities were compared with soil spectra from laboratory measurements. Emissivities were measured for the bands of a multispectral radiometer CE312-2 with effective wavelengths at 8.4, 8.7, 9.1, 10.6, and 11.3 mum…
An Improved Forecasting Model from Satellite Imagery Based on Optimum Wavelet Bases and Adam Optimized LSTM Methods
2021
This paper proposes a new hybrid approach I-WT-LSTM (i.e., Improved Wavelet Long Short-Term Memory (LSTM) Model) for forecasting non-stationary time series (TS) from satellite imagery. The proposed approach consists of two steps: The first step aims at decomposing TS using Multi-Resolution Analysis wavelet (MRA-WT) into inter-and intra-annual components using 18 different mother wavelets (MW). Then, the energy to Shannon entropy ratio criterion is calculated to select the best MW. The second step is based on the LSTM model using Adam optimizer to predict the future. The proposed approach is tested using TS derived from Moderate Resolution Imaging Spectroradiometer (MODIS) images from 2001 t…
Discrimination of coral reflectance spectra in the Red Sea
2002
Benthic populations can potentially be mapped from remotely acquired spectral imagery, provided that they have distinctive reflectance signatures. We examined the spectral reflectance characteristics of 14 genera of Red Sea coral using a submersible spectroradiometer. Coral spectra varied quantitatively and qualitatively over the depth interval 5–20 m. Tissue pigment content had a larger effect on reflectance than colony morphology. Ten coral genera could be discriminated with a statistical probability of 52% on the basis of their absolute reflectance. Six groups of two to three coral genera could be discriminated with a probability of 60% on the basis of their rates of change in reflectanc…
Camera-based measurement of relative image contrast in projection displays
2013
International audience; This research investigated the measured contrast of projection displays based on pictures taken by un-calibrated digital cameras under typical viewing conditions. A high-end radiometer was employed as a reference to the physical response of projection luminance. Checkerboard, gray scale and color complex test images with a range of the projector's brightness and contrast settings were projected. Two local and two global contrast metrics were evaluated on the acquired pictures. We used contrast surface plots and Pearson correlation to investigate the measured contrast versus the projector's brightness and contrast settings. The results suggested, as expected, the proj…
Airborne observations of far-infrared upwelling radiance in the Arctic
2016
Abstract. The first airborne measurements of the Far-InfraRed Radiometer (FIRR) were performed in April 2015 during the panarctic NETCARE campaign. Vertical profiles of spectral upwelling radiance in the range 8–50 μm were measured in clear and cloudy conditions from the surface up to 6 km. The clear-sky profiles highlight the strong dependence of radiative fluxes to the temperature inversion typical of the Arctic. Measurements acquired for total column water vapor from 1.5 to 10.5 mm also underline the sensitivity of the far-infrared greenhouse effect to specific humidity. The cloudy cases show that optically thin ice clouds increase the cooling rate of the atmosphere by a factor up to thr…
The 2016 CEOS Infrared Radiometer Comparison: Part II: Laboratory Comparison of Radiation Thermometers
2019
AbstractTo ensure confidence, measurements carried out by imaging radiometers mounted on satellites require robust validation using “fiducial quality” measurements of the same in situ parameter. For surface temperature measurements this is optimally carried out by radiometers measuring radiation emitted in the infrared region of the spectrum, collocated to that of a satellite overpass. For ocean surface temperatures the radiometers are usually on board ships to sample large areas but for land and ice they are typically deployed at defined geographical sites. It is of course critical that the validation measurements and associated instrumentation are internationally consistent and traceable …