Search results for "Radiosonde"
showing 10 items of 29 documents
Atmospheric water vapor content over land surfaces derived from the AVHRR data: application to the Iberian Peninsula
1999
A study has been carried out using simulated NOAA/advanced very high resolution radiometer (AVHRR) data at 11 and 12 /spl mu/m (with LOWTRAN-7, MODTRAN 2.0, and the TIGR database), AVHRR images of the Iberian Peninsula and the Palma de Mallorca Island, radiosonde observations at seven meteorological stations, and the AVISO database provided by Meteo France to describe, compare, and analyze two different approaches for estimating the total atmospheric water vapor content (W) over land surfaces from AVHRR data. These two techniques are: 1) the split-window covariance-variance ratio (SWCVR), based on a quadratic relationship between W and the ratio of the spatial covariance and variance of bri…
Description of atmospheric conditions at the Pierre Auger Observatory using the Global Data Assimilation System (GDAS)
2012
Atmospheric conditions at the site of a cosmic ray observatory must be known for reconstructing observed extensive air showers. The Global Data Assimilation System (GDAS) is a global atmospheric model predicated on meteorological measurements and numerical weather predictions. GDAS provides altitude-dependent profiles of the main state variables of the atmosphere like temperature, pressure, and humidity. The original data and their application to the air shower reconstruction of the Pierre Auger Observatory are described. By comparisons with radiosonde and weather station measurements obtained on-site in Malargüe and averaged monthly models, the utility of the GDAS data is shown.
Comparison of top of the atmosphere GERB measured radiances with independent radiative transfer simulations obtained at the Valencia Anchor Station a…
2005
The purpose of this work is to compare top of the atmosphere (TOA) radiances as measured by the Geostationary Earth Radiation Budget (GERB) instrument on board the METEOSAT-8 (METEOSAT Second Generation) satellite to equivalent independent radiances obtained from radiative transfer simulations performed using surface and atmospheric measured parameters gathered during the GERB Surface Ground Validation Campaign at the Valencia Anchor Station (VAS) reference area in February 2004. In this paper we try to extend the methodology previously developed and tested for the NASA Clouds and the Earth's Radiant Energy System (CERES) instrument in the framework of the SEVIRI and GERB Cal/val Area for L…
Temperature-based and radiance-based validations of the V5 MODIS land surface temperature product
2009
[1] The V5 level 2 land surface temperature (LST) product of the Moderate Resolution Imaging Spectroradiometer (MODIS) was validated over homogeneous rice fields in Valencia, Spain, and the Hainich forest in Germany. For the Valencia site, ground LST measurements were compared with the MOD11_L2 product in the conventional temperature-based (T-based) method. We also applied the alternative radiance-based (R-based) method, with in situ LSTs calculated from brightness temperatures in band 31 through radiative transfer simulations using temperature and water vapor profiles and surface emissivity data. At the Valencia site, profiles were obtained from local radiosonde measurements and from Natio…
Consistency between GRUAN sondes, LBLRTM and IASI
2017
Abstract. Radiosonde soundings from the GCOS Reference Upper-Air Network (GRUAN) data record are shown to be consistent with Infrared Atmospheric Sounding Instrument (IASI)-measured radiances via LBLRTM (Line-By-Line Radiative Transfer Model) in the part of the spectrum that is mostly affected by water vapour absorption in the upper troposphere (from 700 hPa up). This result is key for climate data records, since GRUAN, IASI and LBLRTM constitute reference measurements or a reference radiative transfer model in each of their fields. This is specially the case for night-time radiosonde measurements. Although the sample size is small (16 cases), daytime GRUAN radiosonde measurements seem to h…
Balloon-borne match measurements of midlatitude cirrus clouds
2014
Observations of high supersaturations with respect to ice inside cirrus clouds with high ice water content (> 0.01 g kg−1) and high crystal number densities (> 1 cm−3) are challenging our understanding of cloud microphysics and of climate feedback processes in the upper troposphere. However, single measurements of a cloudy air mass provide only a snapshot from which the persistence of ice supersaturation cannot be judged. We introduce here the "cirrus match technique" to obtain information about the evolution of clouds and their saturation ratio. The aim of these coordinated balloon soundings is to analyze the same air mass twice. To this end the standard radiosonde equipment is complemente…
Summertime columnar content of atmospheric water vapor from ground-based Sun-sky radiometer measurements through a new in situ procedure
2010
[1] A new in situ technique for the retrieval of atmospheric water vapor content (i.e., precipitable water content) from Sun photometric direct solar irradiance measurements, taken at the 940 nm wavelength during clear‐sky conditions, is presented. The procedure is applied to summer data recorded in 2007, 2008, and 2009 with a Sun‐sky radiometer at the San Pietro Capofiume station in the Po valley, Italy. It is a preliminary development of the retrieval procedure providing the columnar water vapor content from measurements performed with PREDE Sun‐sky radiometers. The technique brings improvement and innovation by retrieving the best values of constants (a and b), characterizing atmospheric…
Synoptic-scale variability of the polar and subpolar tropopause: Data analysis and idealized PV inversions
2002
The synoptic-scale variability of the polar and subpolar tropopause is investigated based on radiosonde and European Centre for Medium-Range Weather Forecasts Reanalysis data in combination with idealized potential vorticity (PV) inversions. A regression analysis is performed to examine the relationship between the relative vorticity at tropopause level, the tropopause displacement, the static stability above the tropopause, and the anomalies of tropopause temperature and potential temperature. The results are compared with regression coefficients computed from a large number of PV inversions. Generally, a cyclonically influenced tropopause is lower, warmer and potentially colder than avera…
Trends in column integrated water vapour over Europe from 1973 to 2003
2010
The spatial and temporal variations of atmospheric precipitable water (PW) content anomalies were analysed over Europe from 1973 to 2003 using daily data (0000 and 1200 UTC) from National Center of Environmental Prediction and National Center of Atmospheric Research Reanalysis project (NCEP-1) and in situ radiosonde data. Mann–Kendall trend tests were applied to long-term PW time series. Technology changes influence PW radiosonde trends, although these are in agreement with NCEP-1 trends. Over the south of the Iberian Peninsula, trends are negative and statistically significant ( 0.04 mm year−1; p < 0.05). Seasonal trends revealed negative and significant trends over the Iberian Peninsula f…
Validation of Landsat-7/ETM+ Thermal-Band Calibration and Atmospheric Correction With Ground-Based Measurements
2010
Ground-based measurements of land-surface temperature (LST) performed in a homogeneous site of rice crops close to Valencia, Spain, were used for the validation of the calibration and the atmospheric correction of the Landsat-7 Enhanced Thematic Mapper Plus (ETM+) thermal band. Atmospheric radiosondes were launched at the test site around the satellite overpasses. Field-emissivity measurements of the near-full-vegetated rice crops were also performed. Seven concurrences of Landsat-7 and ground data were obtained in July and August 2004-2007. The ground measurements were used with the MODTRAN-4 radiative transfer model to simulate at-sensor radiances and brightness temperatures, which were c…