Search results for "Radioterapia"
showing 10 items of 574 documents
Value of texture analysis on gadoxetic acid–enhanced MRI for differentiating hepatocellular adenoma from focal nodular hyperplasia
2019
OBJECTIVE. The objective of our study was to assess the diagnostic performance of texture analysis (TA) on gadoxetic acid-enhanced MR images for differentiation of hepatocellular adenoma (HCA) from focal nodular hyperplasia (FNH).MATERIALS AND METHODS. This study included 40 patients (39 women and one man) with 51 HCAs and 28 patients (27 women and one man) with 32 FNH lesions. All lesions were histologically proven with preoperative MRI performed with gadoxetic acid. Two readers reviewed all the imaging sequences to assess the qualitative MRI characteristics. The T2-weighted fast spin-echo, hepatic arterial phase (HAP), and hepatobiliary phase (HBP) sequences were used for TA. Textural fea…
Enhancement pattern of hepatocellular adenoma (HCA) on MR imaging performed with Gd-EOB-DTPA versus other Gd-based contrast agents (GBCAs): An intrai…
2019
Purpose: To conduct an intraindividual comparison of the enhancement pattern of hepatocellular adenoma (HCA) on dynamic MRI study obtained following the injection of Gadoxetic acid (Gd-EOB-DTPA) and other gadolinium-based contrast agents (GBCAs).Method: This is a retrospective, Institutional Review Board-approved study conducted in a single institution. A search of medical records between 2008 and 2017 revealed 17 patients (all females) with at least one pathologically-proven HCA who underwent liver MRI with Gd-EOB-DTPA and another GBCA within 1 year. Enhancement of each lesion on hepatic arterial (HAP), portal venous (PVP), 2 min and 4-5 minutes phases was subjectively evaluated by two abd…
Cardiac Magnetic Resonance with Delayed Enhancement of the Right Ventricle in patients with Left Ventricle primary involvement: diagnosis and evaluat…
2020
: Cardiac Magnetic Resonance (CMR) allows an accurate Right Ventricle (RV) assessment that could be of great relevance in diseases causing inflammation or fibrosis. The aim of this study was to evaluate the concomitant involvement of the RV in patients with delayed enhancement (DE) of the Left Ventricle (LV-DE) using CMR. We retrospectively enrolled 95 (male n. 66; age 55±18years; BMI 26±5kg/m2) consecutive patients with LV-DE who underwent a CMR (Achieva 1.5 T, Philips) for different indications: post-ischemic dilated cardiopathy (PDM), hypertrophic cardiomyopathy (HCM), myocardial infarction (MI), myocarditis/pericarditis (MP) and congenital heart disease (CD). We assessed the presence an…
Hepatocellular carcinoma in cirrhotic patients at multidetector CT: hepatic venous phase versus delayed phase for the detection of tumour washout.
2011
OBJECTIVES: Our aim was to compare retrospectively hepatic venous and delayed phase images for the detection of tumour washout during multiphasic multidetector row CT (MDCT) of the liver in patients with hepatocellular carcinoma (HCC). METHODS: 30 cirrhotic patients underwent multiphasic MDCT in the 90 days before liver transplantation. MDCT was performed before contrast medium administration and during hepatic arterial hepatic venous and delayed phases, images were obtained at 12, 55 and 120 s after trigger threshold. Two radiologists qualitatively evaluated images for lesion attenuation. Tumour washout was evaluated subjectively and objectively. Tumour-to-liver contrast (TLC) was measured…
Diagnostic value of MR-based texture analysis for the assessment of hepatic fibrosis in patients with nonalcoholic fatty liver disease (NAFLD)
2019
PurposeTo investigate the performance of MR-based texture analysis (TA) for the assessment of hepatic fibrosis in patients with nonalcoholic fatty liver disease (NAFLD).MethodsFifty-four adult patients (33 females, 21 males, mean age 49.813.5years) with biopsy-proven NAFLD were enrolled and underwent MR imaging on a 1.5T system. TA parameters were extracted on axial noncontrast 3D-GRE T1W images (slice thickness=4.6mm) using a commercially available research software (TexRAD). Receiver operating curves (ROC), areas under the ROC (AUROC) and 95% confidence intervals (CI) were calculated to assess the accuracy of each TA parameter for the diagnosis of significant (F2) and advanced fibrosis (F…
A semi-automatic approach for epicardial adipose tissue segmentation and quantification on cardiac CT scans
2019
Abstract Many studies have shown that epicardial fat is associated with a higher risk of heart diseases. Accurate epicardial adipose tissue quantification is still an open research issue. Considering that manual approaches are generally user-dependent and time-consuming, computer-assisted tools can considerably improve the result repeatability as well as reduce the time required for performing an accurate segmentation. Unfortunately, fully automatic strategies might not always identify the Region of Interest (ROI) correctly. Moreover, they could require user interaction for handling unexpected events. This paper proposes a semi-automatic method for Epicardial Fat Volume (EFV) segmentation a…
Evaluation of texture analysis for the differential diagnosis of focal nodular hyperplasia from hepatocellular adenoma on contrast-enhanced CT images
2018
PurposeTo explore the value of CT texture analysis (CTTA) for differentiation of focal nodular hyperplasia (FNH) from hepatocellular adenoma (HCA) on contrast-enhanced CT (CECT).MethodsThis is a retrospective, IRB-approved study conducted in a single institution. A search of the medical records between 2008 and 2017 revealed 48 patients with 70 HCA and 50 patients with 62 FNH. All lesions were histologically proven and with available pre-operative CECT imaging. Hepatic arterial phase (HAP) and portal venous phase (PVP) were used for CTTA. Textural features were extracted using a commercially available research software (TexRAD). The differences between textural parameters of FNH and HCA wer…
Computed tomography coronary angiography in asymptomatic patients
2011
This study assessed the accuracy of computed tomography coronary angiography (CT-CA) for detecting significant coronary artery disease (CAD; a parts per thousand yen50% lumen reduction) in intermediate/high-risk asymptomatic patients. A total of 183 consecutive asymptomatic individuals (92 men; mean age 54 +/- 11 years) with more than one major risk factor (obesity, hypertension, diabetes, hypercholesterolaemia, family history, smoking) and an inconclusive or nonfeasible noninvasive stress test result (stress electrocardiography, stress echocardiography, nuclear stress scintigraphy) underwent CT-CA in an outpatient setting. All patients underwent conventional coronary angiography (CAG) with…
Three-dimensional (3D) versus two-dimensional (2D) laparoscopic adrenalectomy: A case-control study
2016
Abstract Introduction Laparoscopic adrenalectomy is today considered the gold standard of treatment for adrenal tumors. The development of high definition cameras does not eliminate the major limitation of two-dimensional (2D) laparoscopy: lack of depth perception and loss of spatial orientation. Tree-dimensional (3D) HD laparoscopy was developed as an alternative to conventional 2D laparoscopy. Methods We report our experience with use of 3D vision system for laparoscopic adrenalectomy. Between January 2009 and March 2015 we performed a total of 52 laparoscopic adrenalectomies. In this case-control study we considered 13 laparoscopic adrenalectomies performed with three-dimensional (3D) vi…
Utility of CT in the diagnosis of pancreatic fistula after pancreaticoduodenectomy in patients with soft pancreas.
2009
OBJECTIVE: The purpose of this study was to evaluate the sensitivity and specificity of routine performance of CT on postoperative day 7 in patients at high risk of pancreatic fistula after pancreaticoduodenectomy. MATERIALS AND METHODS: Two radiologists analyzed images from CT examinations of 50 patients with soft pancreas 7 days after pancreaticoduodenectomy. Pancreatic fistula was defined at CT as a fluid collection close to the pancreaticogastric or pancreaticojejunal anastomosis. Clinicobiologic criteria for the diagnosis of pancreatic fistula were drain output of any measurable volume of fluid on or after postoperative day 3 that had an amylase content more than three times the serum …