Search results for "Rao"

showing 10 items of 1049 documents

Reading ability with 3 multifocal intraocular lens models.

2006

Purpose To prospectively evaluate reading performance with of 3 types of multifocal intraocular lenses (IOLs) under different lighting conditions based on reading acuity and reading speed tests. Setting Augenklinik, Bad Hersfeld, Germany. Methods This randomized study comprised 60 cataract patients (120 eyes) randomly assigned to receive an SA40N IOL (AMO) (Group 1, 20 patients), Tecnis ZM001 IOL (AMO) (Group 2, 20 patients), or AcrySof ReSTOR SA60D3 IOL (Alcon) (Group 3, 20 patients). Pupil size and reading ability at near (visual acuity, reading speed) without correction, with best distance correction, and with best near correction were assessed 6 weeks postoperatively under low-light con…

medicine.medical_specialtyVisual acuitygenetic structuresLightPseudophakiamedicine.medical_treatmentmedia_common.quotation_subjectEye diseaseVisual AcuityIntraocular lensContrast SensitivityLens Implantation IntraocularOphthalmologyReading (process)medicineHumansProspective Studiesmedia_commonLenses IntraocularPhacoemulsificationbusiness.industrySignificant differencePupil sizePupilMultifocal intraocular lensMiddle Agedmedicine.diseaseDistance correctioneye diseasesSensory SystemsOphthalmologyReadingOptometrySurgerysense organsmedicine.symptombusinessJournal of cataract and refractive surgery
researchProduct

The Impact on Vision of Aspheric to Spherical Monofocal Intraocular Lenses in Cataract Surgery

2013

Purpose To provide a summary of the impact on vision of an aspheric intraocular lens (IOL) compared with a spherical IOL in cataract surgery. Design Systematic review with meta-analysis. Participants Patients from published randomized controlled trials (RCTs) of cataract surgery with aspheric compared with spherical monofocal IOL implantation. Methods We systematically searched the peer-reviewed literature in MEDLINE, EMBASE, Web of Science, BIOSIS, and the Cochrane Library according to the Cochrane Collaboration method to identify relevant RCTs. The inclusion criteria were RCTs on cataract surgery comparing the use of aspheric versus spherical IOL implantation that assessed visual acuity, …

medicine.medical_specialtyVisual acuitygenetic structuresbusiness.industryMesopic visionmedia_common.quotation_subjectmedicine.medical_treatmentIntraocular lensCochrane LibraryCataract surgeryeye diseasesOphthalmologyMeta-analysisOphthalmologyContrast (vision)MedicineOptometrysense organsmedicine.symptombusinessmedia_commonPhotopic visionOphthalmology
researchProduct

Anwendungsm�glichkeiten der intraoperativen Sonographie

1983

Sonographie, Computertomographie, Angiographie und endoskopisch retrograde Cholangiopancreaticographie haben sich in der Allgemein- und Gefaschirurgie als wertvolle Untersuchungsmethoden etabliert. Schwierigkeiten bestehen jedoch manchmal in der Korrelation der Praoperativen Befunde mit dem intraoperativen Befund. Hier ist das Anwendungsgebiet der intraoperativen Sonographie (IOS) zu sehen. Sie bietet dem Chirurgen eine zusatzliche Information durch Darstellung von pathologischen Gefasprozessen, Kontrolle von Gefasanastomosen, intraoperative FlowMessung in Gefasen, Lokalisationsdiagnostik in parenchymatosen Organen. Die intraoperative Sonographie ist somit ein neues Instrument des Chirurgen…

medicine.medical_specialtybusiness.industryCardiothoracic surgerymedicineSurgeryIntraoperative PeriodVascular surgeryUltrasonographyNuclear medicinebusinessAbdominal surgeryLangenbecks Archiv f�r Chirurgie
researchProduct

Modifications of a nerve integrity monitor useful in skull base surgery.

1993

medicine.medical_specialtybusiness.industryCranial nervesCranial NervesAnatomyEquipment DesignSurgery03 medical and health sciences0302 clinical medicineOtorhinolaryngologyEvaluation Studies as Topic030220 oncology & carcinogenesisMonitoring IntraoperativeElectroneuronographySkull base surgerymedicineHumansSurgery030223 otorhinolaryngologybusinessElectrodesOtolaryngology--head and neck surgery : official journal of American Academy of Otolaryngology-Head and Neck Surgery
researchProduct

Anterior Corneal Folds in Postoperative Hypotony Following Glaucoma Drainage Surgery

2020

medicine.medical_specialtybusiness.industryGlaucomaOcular Hypotensionmedicine.diseaseTonometry OcularOphthalmologyGlaucoma drainage surgeryOphthalmologyHumansMedicineGlaucoma Drainage ImplantsbusinessIntraocular PressureJournal of Glaucoma
researchProduct

Patients' cosmetic satisfaction, pain, and functional outcomes after supraorbital craniotomy through an eyebrow incision

2014

Object The supraorbital approach through an eyebrow incision offers the opportunity to access a wide variety of lesions of the anterior, middle, and even the posterior fossa. The minimally invasive keyhole craniotomy limits brain exploration and retraction and offers the potential for improved surgical outcomes and reduced approach-related complications. Patient satisfaction, however, has not yet been reported in the literature. Methods From January 2002 through December 2011, the lead author (R.R.) used a supraorbital approach through an eyebrow incision for 418 patients with cerebral aneurysms, brain tumors or cystic lesions, and other miscellaneous pathological conditions. For 408 of th…

medicine.medical_specialtybusiness.industryMortality rateEyebrowSupraorbital craniotomyPerioperativeSurgeryPatient satisfactionmedicine.anatomical_structureKeyhole craniotomymedicineCase notebusinessPathologicalJournal of Neurosurgery
researchProduct

Modeling the pelvic region for non-invasive pelvic intraoperative neuromonitoring

2016

Abstract Finite element analysis (FEA) of electric current distribution in the pelvis minor may help to assess the usability of non-invasive surface stimulation for continuous pelvic intraoperative neuromonitoring. FEA requires generation of quality volumetric tetrahedral mesh geometry. This study proposes the generation of a suitable mesh based on MRI data. The resulting volumetric mesh models the autonomous nerve structures at risk during total mesorectal excision. The model also contains the bone, cartilage, fat, skin, muscle tissues of the pelvic region, and a set of electrodes for surface stimulation. The model is ready for finite element analysis of the discrete Maxwell’s equations.

medicine.medical_specialtybusiness.industryfinite element methodlcsh:RNon invasiveBiomedical Engineeringlcsh:Medicinepelvic intraoperative neurophysiological monitoring03 medical and health sciences0302 clinical medicinemedicine.anatomical_structure030220 oncology & carcinogenesismedicine030211 gastroenterology & hepatologyelectric field modelingRadiologybusinessPelvisCurrent Directions in Biomedical Engineering
researchProduct

SU-G-201-02: Application of RayStretch in Clinical Cases: A Calculation for Heterogeneity Corrections in LDR Permanent I-125 Prostate Brachytherapy

2016

Purpose: Tissue heterogeneities and calcifications have significant impact on the dosimetry of low energy brachytherapy (BT). RayStretch is an analytical algorithm developed in our institution to incorporate heterogeneity corrections in LDR prostate brachytherapy. The aim of this work is to study its application in clinical cases by comparing its predictions with the results obtained with TG-43 and Monte Carlo (MC) simulations. Methods: A clinical implant (71 I-125 seeds, 15 needles) from a real patient was considered. On this patient, different volumes with calcifications were considered. Its properties were evaluated in three ways by i) the Treatment planning system (TPS) (TG-43), ii) a M…

medicine.medical_specialtybusiness.industrymedicine.medical_treatmentMonte Carlo methodBrachytherapyHigh densityGeneral MedicineIntraoperative ultrasoundmedicineDosimetryChristian ministryMedical physicsbusinessNuclear medicineRadiation treatment planningProstate brachytherapyMedical Physics
researchProduct

Towards clinical application of RayStretch for heterogeneity corrections in LDR permanent 125-I prostate brachytherapy

2017

Purpose RayStretch is a simple algorithm proposed for heterogeneity corrections in low-dose–rate brachytherapy. It is built on top of TG-43 consensus data, and it has been validated with Monte Carlo (MC) simulations. In this study, we take a real clinical prostate implant with 71 125I seeds as reference and we apply RayStretch to analyze its performance in worst-case scenarios. Methods and Materials To do so, we design two cases where large calcifications are located in the prostate lobules. RayStretch resilience under various calcification density values is also explored. Comparisons against MC calculations are performed. Results Dose–volume histogram–related parameters like prostate D90, …

medicine.medical_specialtybusiness.industrymedicine.medical_treatmentMonte Carlo methodBrachytherapyProstate implant030218 nuclear medicine & medical imagingIntraoperative ultrasound03 medical and health sciences0302 clinical medicinemedicine.anatomical_structureOncologyPròstataProstate030220 oncology & carcinogenesismedicineDosimetryRadiology Nuclear Medicine and imagingMedical physicsRadiation treatment planningbusinessBraquiteràpiaProstate brachytherapy
researchProduct

Die Sonoanatomie des Spinalkanales der LWS

2008

UNLABELLED Results of an Experimental Study and Report of Intraoperative Application: AIM Intraoperative sonography has been used in neurosurgery (especially in tumors) and in traumatology (assess reduction of dorsal vertebral body fragments). This study was performed to determine the value of sonography in detecting vertebral disc tissue. RESULTS We examined 6 specimens of the Lumbar spine using the extended flavectomy approach. We found that sono-anatomy was reproducible and that the assessable area was large enough to make sonography useful for detection of sequesters. Dislocated vertebral disc tissue could be differentiated clearly from original disc tissue and from other intraspinal st…

medicine.medical_specialtybusiness.industrymedicine.medical_treatmentUltrasoundTraumatologyComplete resectionIntraoperative ultrasoundmedicine.anatomical_structuremedicineRadiology Nuclear Medicine and imagingLumbar spineSpinal canalRadiologyNeurosurgerybusinessReduction (orthopedic surgery)Ultraschall in der Medizin
researchProduct