Search results for "Reagent"

showing 10 items of 699 documents

On-line solvent recycling: a tool for the development of clean analytical chemistry in flow injection Fourier transform infrared spectrometry. Determ…

1998

Abstract A flow injection strategy has been developed for the direct determination of ketoprofen in pharmaceuticals by Fourier transform infrared spectrometry also incorporating a distillation unit which allows the carbon tetrachloride employed to dissolve samples and standards and used as a carrier to be recovered on-line. The system developed permits a drastic reduction of reagent consumption and easy and fast sampling and cleaning of the measurement cell. For the quantification of ketoprofen in pharmaceuticals the carbonyl bands at 1712 and 1666 cm −1 were employed and the developed method provided a 3 σ limit of detection of 0.04 mg ml −1 , a dynamic range up to 10 mg ml −1 and typical …

Detection limitChromatographyDynamic rangeChemistryAnalytical chemistryInfrared spectroscopyBiochemistryAnalytical Chemistrylaw.inventionSolventsymbols.namesakeFourier transformlawReagentsymbolsEnvironmental ChemistryQuantitative analysis (chemistry)DistillationSpectroscopyAnalytica Chimica Acta
researchProduct

Preconcentration and dansylation of aliphatic amines using C18 solid-phase packings

2002

Abstract Precolumn preconcentration and derivatization on solid sorbents (Bond Elut C18 solid-phase extraction cartridges) of low-molecular-mass aliphatic amines in water samples have been performed using dansyl chloride (Dns-Cl) as derivatization reagent. Conditions for analyte preconcentration and derivatization such as volume sample, reagent concentration, time, pH and temperature reaction were optimised. On the basis of these studies a rapid and sensitive method for screening of aliphatic amines in waters is presented. Up to volumes of 5 ml, samples are drawn through the sorbent, the analytes retained are dansylated at basic pH, at 100 °C for 10 min or 85 °C for 15 min. The derivatized …

Detection limitChromatographyElutionOrganic ChemistryDansyl chlorideGeneral MedicineReversed-phase chromatographyBiochemistryAnalytical Chemistrychemistry.chemical_compoundchemistryReagentSample preparationSolid phase extractionDerivatizationJournal of Chromatography A
researchProduct

Univariate near infrared methods for determination of pesticides in agrochemicals

2006

Abstract It has been developed a general strategy for the determination of pesticides in agrochemicals by Fourier transform near infrared (FT-NIR) spectroscopy. The methodology is based on previous extraction of the active principles through sonication with acetonitrile and direct determination by transmission measurements, using glass vials as measurement cells and univariate calibration at selected wavenumbers as a function of the pesticide to be analyzed. Chlorsulfuron, metamitron, iprodione, pirimicarb, procymidone and tricyclazole were used as test molecules and data obtained by FT-NIR for 20 samples containing one of these active principles compare well with those found by reference l…

Detection limitChromatographyExtraction (chemistry)Analytical chemistryPirimicarbBiochemistryHigh-performance liquid chromatographyFourier transform spectroscopyAnalytical Chemistrychemistry.chemical_compoundchemistryReagentEnvironmental ChemistrySample preparationProcymidoneSpectroscopyAnalytica Chimica Acta
researchProduct

A chemiluminescence flow-based procedure for determination of carbaryl in natural waters exploiting multicommutation and enzymatic reaction

2007

A chemiluminescence procedure for the determination of carbaryl in natural waters using acetylcholinesterase and choline oxidase is described. The flow system designed to implement multicommutation approach controlled by microcomputer comprised five solenoid valves, two columns with immobilized enzymes on controlled pore glass beads and chemiluminometric flow cell. In the best experimental conditions a linear response ranging from 25 to 700 µg L-1 carbaryl was obtained. Water samples were spiked with carbaryl in order to access the accuracy and recoveries between 95 and 101% were obtained for a concentration level ranging from 25 to 100 µg L-1 carbaryl. Detection limit and variation coeffic…

Detection limitChromatographyImmobilized enzymeChemistryPotassiumchemistry.chemical_elementGeneral ChemistryCholine oxidasechemiluminescenceLuminollaw.inventionpesticide carbarylchemistry.chemical_compoundmulticommutationlawReagentCarbarylflow analysisChemiluminescenceenzymatic reaction
researchProduct

In-tube solid-phase microextraction and liquid chromatography using a monolithic column for the selective determination of residual ethylenediamine i…

2009

The selective determination of the diamine ethylenediamine (EDA) in the presence of a higher amount of residual dimethylamine in cationic polymers has been developed. The strategy uses both a solution derivatization with a selective agent of primary amines such as o-phthaldialdehyde-N-acetyl-L-cysteine (OPA-NAC) and an in-tube solid-phase microextraction (IT-SPME) coupled to liquid chromatography (LC). A 70 cm long, 0.32 mm internal diameter, and 3 microm thick commercially available capillary column coated with 95% polydimethylsiloxane and 5% polydiphenylsiloxane was employed to replace the injection loop of a Rheodyne injection valve. A volume of 1 mL of derivatized sample was passed thro…

Detection limitChromatographyMonolithic HPLC columnPolydimethylsiloxaneCapillary actionPolymersCationic polymerizationSolid-phase microextractionEthylenediaminesAnalytical Chemistrychemistry.chemical_compoundchemistryChemical IndustryIndicators and ReagentsDerivatizationDimethylamineSolid Phase MicroextractionChromatography LiquidAnalytical chemistry
researchProduct

Automated on-line in-tube solid-phase microextraction-assisted derivatization coupled to liquid chromatography for quantifying residual dimethylamine…

2008

Abstract A method for the analysis of dimethylamine (DMA) by automated in-tube solid-phase microextraction (IT-SPME)-supported chemical derivatization coupled with high-performance liquid chromatography was developed. Extraction, derivatization and desorption were studied by using a capillary coated with 95% polydimethylsiloxane and 5% polydiphenylsiloxane. Solution derivatization and automated IT-SPME derivatization using 9-fluorenylmethyl chloroformate (FMOC) were compared. The proposed procedure provided adequate linearity, accuracy and precision in the 0.2–2.0 μg/mL concentration interval, and the limit of detection (LOD) was 50 ng/mL. The main advantages of the proposed procedure are: …

Detection limitChromatographyPolymersChemistryOrganic ChemistryGeneral MedicineChloroformateSolid-phase microextractionOnline SystemsBiochemistryHigh-performance liquid chromatographyAnalytical Chemistrychemistry.chemical_compoundReagentSample preparationDerivatizationDimethylamineDimethylaminesSolid Phase MicroextractionChromatography Liquid
researchProduct

Micellar modified spectrophotometric determination of nitrobenzenes based upon reduction with tin(II), diazotisation and coupling with the Bratton–Ma…

1997

Abstract Nitrobenzenes, such as the antibiotic chloramphenicol, the vasodilator nicardipine, and the herbicides dinitramin, dinobuton, fenitrothion, methylparathion, oxyfluorfen, parathion, pendimethalin, quintozene, and trifluralin, were determined by using a spectrophotometric method in the visible region (540 nm). The method was based on the reduction of the nitrobenzenes to arylamines with tin(II) chloride, diazotisation of the arylamines and coupling of the diazonium ions with the Bratton–Marshall reagent. The two latter reactions were performed in a micellar medium of sodium dodecyl sulphate. The linear calibration range was 2×10 −6 to 7×10 −5 M ( r >0.999), with limits of detection i…

Detection limitChromatographySodiumTrifluralinchemistry.chemical_elementChlorideAnalytical ChemistryNitrobenzenechemistry.chemical_compoundParathionchemistryReagentmedicineTinmedicine.drugTalanta
researchProduct

Amphetamine and methamphetamine determination in urine by reversed-phase high-performance liquid chromatography with sodium 1,2-napthoquinone 4-sulfo…

1995

A rapid method is described for the identification and determination of amphetamine and methamphetamine in human urine samples by liquid chromatography with UV-Vis detection. The samples were transferred onto a C18 solid-phase extraction column and chromatographed on a Hypersil ODS RP C18, 5 microns (250 x 4 mm I.D.) with an acetonitrile-water elution gradient containing propylamine. Under these conditions, the amines are eluted with a short retention time. The procedure has been applied to the determination of amphetamine and methamphetamine in the range 0.3-4.0 micrograms/ml in spiked urine samples. The detection limits at 280 nm were 4 and 2 ng/ml for amphetamine and methamphetamine, res…

Detection limitChromatographySpectrophotometry InfraredElutionChemistryExtraction (chemistry)Reproducibility of ResultsPropylamineGeneral ChemistryMethamphetamineHigh-performance liquid chromatographyMethamphetamineAmphetaminechemistry.chemical_compoundmedicineHumansIndicators and ReagentsSolid phase extractionQuantitative analysis (chemistry)Chromatography High Pressure LiquidNaphthoquinonesmedicine.drugJournal of Chromatography B: Biomedical Sciences and Applications
researchProduct

Determination of UV-filters in sunscreens by HPLC.

2001

Simultaneous determination of six internationally authorised organic UV-filters in sunscreen formulations was performed by HPLC with UV spectrophotometric detection. The filters determined were: sulisobenzone, oxybenzone, octyl dimethyl PABA, octyl methoxycinnamate, octyl salicylate and homosalate. A C18 stationary phase and a mobile phase of ethanol water acetic acid (70 : 29.5 : 0.5) were used with a flow rate of 0.5 mL/min. UV measurements were carried out at 313 nm. The time required for the analysis was 25 min and the limits of detection were between 0.2 and 2 mg/L, except for sulisobenzone, which gave a limit of detection of 20 mg/L. The procedure proposed provides an accurate, fast a…

Detection limitChromatographyUltraviolet RaysOctyl methoxycinnamateReversed-phase chromatographySulisobenzoneBiochemistryHigh-performance liquid chromatographyHomosalatechemistry.chemical_compoundchemistrymedicineOctyl salicylateIndicators and ReagentsOxybenzoneSunscreening AgentsChromatography High Pressure Liquidmedicine.drugFresenius' journal of analytical chemistry
researchProduct

Determination of type A trichothecenes by high-performance liquid chromatography with coumarin-3-carbonyl chloride derivatisation and fluorescence de…

2000

A method for the analysis of type A trichothecenes T-2 toxin, HT-2 toxin, neosolaniol and diacetoxyscirpenol by high-performance liquid chromatography with fluorescence detection using coumarin-3-carbonyl chloride has been developed. Different parameters concerning the analytical procedure such as stability of both the reagent and derivatised analytes, time and temperature of the derivatisation reaction, were studied and optimised. Three different clean-up procedures (solid-phase extraction with silica gel or C-18 cartridges, and liquid-liquid partition between toluene and dihydrogen phosphate buffer) were tested in order to remove the excess reagent peaks. The last procedure gave the best …

Detection limitChromatographybiologyOrganic ChemistryTrichotheceneOryzaGeneral MedicineReversed-phase chromatographyHydrogen-Ion Concentrationbiology.organism_classificationBiochemistryHigh-performance liquid chromatographyFusarium sporotrichioidesZea maysDiacetoxyscirpenolAnalytical Chemistrychemistry.chemical_compoundSpectrometry FluorescencechemistryCoumarinsReagentSample preparationTrichothecenesChromatography High Pressure LiquidFluorescent DyesJournal of chromatography. A
researchProduct