Search results for "Reagent"
showing 10 items of 699 documents
Diagnostic accuracy and potential clinical value of the LightCycler SeptiFast assay in the management of bloodstream infections occurring in neutrope…
2011
Summary Objectives The objectives of this study were to compare the performance of the LightCycler SeptiFast Test MGRADE and conventional blood culture in the etiological diagnosis of febrile episodes occurring in neutropenic and critically ill patients (in the intensive care unit; ICU), and to assess the potential clinical value of the SeptiFast test in patient management. Methods A total of 86 febrile episodes occurring in 33 neutropenic patients and 53 ICU patients were analyzed. Blood samples for blood culture and SeptiFast testing were obtained at the onset of fever, before the implementation of empirical antimicrobial therapy. Results The overall microorganism-to-isolate agreement bet…
ProC® Global Assay in the Evaluation of Women with History of Severe Preeclampsia or HELLP Syndrome
2003
Preeclampsia/HELLP syndrome has been associated with a high incidence of defects in the protein C pathway and increased anticardiolipin-antibodies/lupus anticoagulants. It is also apparent that thrombophilia is responsible for other pregnancy complications, such as recurrent spontaneous abortion, fetal growth restriction, intrauterine fetal death, and abruptio placentae. ProC® Global is a new global clotting assay designed to evaluate the abnormalities in the protein C anticoagulant pathway. It is based on the ability of endogenous activated protein C, generated by activation of protein C by Protac®, to prolong an activated partial thromboplastin time. A total of 61 patients with a history…
Performance characteristics of the new Abbott Real Time MTB assay for detection of Mycobacterium tuberculosis complex in respiratory specimens
2015
The performance of the Abbott Real Time MTB assay for detection of Mycobacterium tuberculosis complex in respiratory specimens was evaluated using a standard culture as the reference. The overall concordance between both methods was 0.95. The assay displayed an excellent sensitivity (100% for smear-positive/92.3% for smear-negative specimens) and specificity (100%).
Lower strength of the human posterior patellar tendon seems unrelated to mature collagen cross-linking and fibril morphology
2009
The human patellar tendon is frequently affected by tendinopathy, but the etiology of the condition is not established, although differential loading of the anterior and posterior tendon may be associated with the condition. We hypothesized that changes in fibril morphology and collagen cross-linking would parallel differences in material strength between the anterior and posterior tendon. Tendon fascicles were obtained from elective ACL surgery patients and tested micromechanically. Transmission electron microscopy was used to assess fibril morphology, and collagen cross-linking was determined by HPLC and calorimetry. Anterior fascicles were markedly stronger (peak stress: 54.3 ± 21.2 vs.…
Acetic acid-guided biopsies after magnifying endoscopy compared with random biopsies in the detection of Barrett's esophagus: a prospective randomize…
2006
Background In contrast to standard video endoscopy, magnifying endoscopy after local acetic acid application enables recognition of mucosal surface architecture. Objective To investigate the diagnostic yield of magnifying endoscopy with acetic acid–targeted biopsies compared to random, 4-quadrant biopsies. Design Prospective randomized trial (ratio 1:1) with crossover design. Setting Two referral hospitals in Germany. Patients Thirty-one patients with Barrett's esophagus or visible columnar-lined lower esophagus. Interventions Patients were randomized to undergo either standard video endoscopy with 4-quadrant biopsies or magnifying endoscopy in conjunction with acetic acid application. All …
Results of the performance verification of the CoaguChek XS system.
2008
Abstract Background This is the first paper reporting a performance verification study of a point-of-care (POC) monitor for prothrombin time (PT) testing according to the requirements given in chapter 8 of the International Organization for Standardization (ISO) 17593:2007 standard “Clinical laboratory testing and in vitro medical devices — Requirements for in vitro monitoring systems for self-testing of oral anticoagulant therapy”. The monitor under investigation was the new CoaguChek XS system which is designed for use in patient self testing. Its detection principle is based on the amperometric measurement of the thrombin activity generated by starting the coagulation cascade using a rec…
Comparison of computed virtual chromoendoscopy and conventional chromoendoscopy with acetic acid for detection of neoplasia in Barrett's esophagus.
2007
Background and study aims Computed virtual chromoendoscopy (CVC) is a new imaging technique that enhances mucosal surface contrast and highlights the vascular pattern without the need for dye-spraying as in conventional chromoendoscopy. The aim of this prospective randomized pilot study with a crossover design was to compare CVC with conventional chromoendoscopy with acetic acid (CAA) for the detection of high grade intraepithelial neoplasia (HGIN) or early cancer in patients with Barrett's esophagus. Patients and methods 57 patients with Barrett's esophagus (mean length 3.8 cm) and a history of HGIN/early cancer or suspected HGIN/early cancer were randomly allocated to undergo either CAA o…
New tools for detecting latent tuberculosis infection: evaluation of RD1-specific long-term response
2009
Abstract Background Interferon-gamma (IFN-γ) release assays (IGRAs) were designed to detect latent tuberculosis infection (LTBI). However, discrepancies were found between the tuberculin skin test (TST) and IGRAs results that cannot be attributed to prior Bacille Calmètte Guerin vaccinations. The aim of this study was to evaluate tools for improving LTBI diagnosis by analyzing the IFN-γ response to RD1 proteins in prolonged (long-term response) whole blood tests in those subjects resulting negative to assays such as QuantiFERON-TB Gold In tube (QFT-IT). Methods The study population included 106 healthy TST+ individuals with suspected LTBI (recent contact of smear-positive TB and homeless) c…
Detection of IgM antibodies specific for measles virus by capture and indirect enzyme immunoassays.
1995
Summary During a measles outbreak, 112 serum specimens from 88 hospitalized patients were received in our laboratory for investigation of a morbilliform rash. These specimens (88 acute- and 24 convalescent-phase) were tested for the presence of measles-specific IgM antibodies by a capture EIA (enzyme immunoassay) using peroxidase-conjugated measles virus antigens and by an indirect EIA. Commercially available indirect EIA kits for measles-specific IgM antibodies were also used and compared with our homemade EIAs. Specificity studies included a collection of serum specimens containing rheumatoid factor, antinuclear antibodies or IgM antibodies specific to other viruses, and sera from blood d…
Assessment of DNA-protein crosslinks in the course of aging in two mouse strains by use of a modified alkaline filter elution applied to whole tissue…
1999
Abstract Two different mouse strains have been used for determination of age dependence of DNA-protein crosslinks by alkaline filter elution: a long lived laboratory strain, NMRI and an accelerated senescence-prone, short lived strain, SAMP1. Five organs were selected: Brain, kidney, lung, heart and liver. Remarkably in all five organs of short lived SAMP1 mice crosslinks increased significantly with age. In NMRI however only in brain and heart a significant rise in old age has been observed, while in the other organs there was no increase in DNA-protein crosslinking. Appreciable mitotic activity which is lacking in brain and heart could be the reason for this difference. Poor repair in all…