Search results for "Reference Values"
showing 10 items of 535 documents
The effects of telmisartan alone or with hydrochlorothiazide on morning and 24-h ambulatory BP control: results from a practice-based study (SURGE 2)
2012
Observational studies have shown that 24-h and morning ambulatory blood pressure (BP) control is low. This large-scale, practice-based study evaluated the effects of telmisartan 40 or 80 mg alone or in combination with hydrochlorothiazide (HCTZ) 12.5 mg on these BP parameters over 8 weeks; treatment was adjusted if clinic BP remained ≥140/90 mm Hg. A total of 863 patients were evaluated (baseline mean clinic BP, morning and 24-h ambulatory BP: 155±15/93±10 mm Hg, 137±15/83±11 mm Hg, 133±14/79±10 mm Hg, respectively; 68% were previously treated at baseline). Telmisartan with/without HCTZ significantly reduced the mean morning ambulatory BP (-8.2/-4.9 mm Hg), daytime ambulatory BP (-8.0/-4.7 …
Diurnal blood pressure curve in children and adolescents
1996
Objective To investigate the diurnal blood pressure curve in healthy normotensive children. Thirty-one children were re-examined after a median interval of 123 days in order to study the reproducibility of the diurnal profile. Subjects Twenty-four-hour ambulatory blood pressure monitoring and conventional blood pressure readings were obtained in 228 normotensive children, whose ages ranged from 6 to 16 years and of whom 116 were boys and 112 girls. Results The conventional blood pressure averaged 99+/-11/57+/-9 mmHg in boys and 98+/-12/56+/-9 mmHg in girls (means+/-SD); the corresponding 24 h pressures were 111+/-7/66+/-5 mmHg and 109+/-7/65+/-5 mmHg, respectively. Of the children, 83% had …
Current and birth weights exert independent influences on nocturnal pressure-natriuresis relationships in normotensive children.
1998
The objective was to study the impact of birth weight on the relationship between ambulatory blood pressure and urinary sodium excretion in children and adolescents. The study included 134 healthy children (61 boys), all Caucasians, who were born at term after a normotensive pregnancy. For each subject, a 24-hour ambulatory blood pressure monitoring and a complete urine collection were simultaneously performed according to the protocols designed. Average ambulatory blood pressure (BP) and the urinary excretion rates for sodium, potassium, and creatinine were calculated separately for 24-hour, awake, and sleep periods defined by a mini-diary. The excretion rate of sodium during sleep time w…
Anterior Segment Biometry and Their Correlation with Corneal Biomechanics in Caucasian Children.
2018
Purpose: To assess the relationship between the corneal biomechanical parameters and the anterior segment parameters in Caucasian children. Methods: This study included 293 eyes from 293 healthy children aged between 6 and 17 years. Corneal hysteresis (CH) and corneal resistance factor (CRF) were evaluated with the Ocular Response Analyzer, axial length (AL) with IOLMaster and the anterior segment with Pentacam. Anterior segment parameters obtained were the following: central corneal thickness (CCT), corneal volume (CV), anterior chamber depth (ACD), anterior chamber volume (ACV) and mean anterior and posterior keratometry. Two multiple linear regression models were constructed to assess th…
Dobutamine stress Doppler echocardiography: reproducibility and physiologic left ventricular filling patterns
1997
Qualitatively, dobutamine stress echocardiography has become an established procedure. Quantitative results are in great demand but this is still difficult due to limited endo- and epicardial border definition. Transmitral Doppler variables are strictly quantitative and less subjective. Furthermore, ischemic alterations precede systolic ones (ischemic cascade). There are preliminary reports of the utility of dobutamine stress Doppler echocardiography, but proof of reproducibility and left ventricular filling patterns are still lacking. Fourteen healthy volunteers (10 men, 4 women, median age 25.9 years, range 21-32 years) were investigated according to the usual dobutamine stress echocardio…
Uptake and storage of choline by rat brain: influence of dietary choline supplementation.
1991
In order to elucidate the regulation of the levels of free choline in the brain, we investigated the influence of chronic and acute choline administration on choline levels in blood, CSF, and brain of the rat and on net movements of choline into and out of the brain as calculated from the arteriovenous differences of choline across the brain. Dietary choline supplementation led to an increase in plasma choline levels of 50% and to an increase in the net release of choline from the brain as compared to a matched group of animals which were kept on a standard diet and exhibited identical arterial plasma levels. Moreover, the choline concentration in the CSF and brain tissue was doubled. In th…
Serial position effects in dementia of the Alzheimer type.
1998
<b>Background: </b>The aim of the present study was to analyse serial position effects for immediate and delayed free recall in patients with dementia of the Alzheimer type and controls. <b>Experiment 1:</b> 44 patients with dementia of the Alzheimer-type and 24 non-demented controls were asked for immediate and delayed free recall of 12 schematic drawings of common objects presented at the rate of 10 s/picture. Steep primacy effects were obtained at all delays in controls. By contrast, primacy effects were significantly impaired in patients with dementia at all delays of recall. Small immediate and delayed recall recency effects were found in both, patients and cont…
New iPAD-based test for the detection of color vision deficiencies.
2018
Purpose: To develop and validate a new iPad-based color vision test (Optopad). Methods: A total of 341 student eyes were enrolled in a first comparative study between Optopad and the Isihara tests. In a second comparative study, Optopad vs. the Farnworth-Munsell test (FM 100H), a total of 66 adult eyes were included. Besides the agreement between tests, the correlation between FM 100H and Optopad outcomes were investigated. Multiple regression analysis was used to predict the total error score (TES) from contrast thresholds measured with the Optopad test. Results: The Ishihara and Optopad tests detected the same anomalous patients. Concerning FM 100H vs. Optopad, 10 subjects were diagnosed …
Comparison of two artificial tear formulations for dry eye through high‐resolution optical coherence tomography
2011
Purpose: The aim was to determine the efficacy of two artificial eye-drop formulations by analysing the lower tear film meniscus volume through a commercial high-resolution spectral-domain optical coherence tomographer. Methods: Twenty dry eye patients (12 men, eight women, aged 57.5 ± 8.4 years) with refractive errors from -2.50 to +0.75 D (mean -1.34 ± 1.02 D) and cylinders lower than 1.00 D were examined. Tear meniscus volume was measured before, immediately after and 10, 30 and 60 minutes after instillation using the Copernicus high-resolution spectral-domain optical coherence tomographer (Optopol Tech SA, Zawiercie, Poland). Volume was calculated from the local area obtained from tom…
Circulating endothelin-1 levels in type 2 diabetic patients with ischaemic heart disease.
1996
To investigate whether circulating endothelin-1 (Et-1) may be related to the increased incidence and severity of ischaemic heart disease in type 2 diabetes mellitus, we compared the concentrations in type 2 diabetic patients and in non-diabetic patients with coronary artery disease (CAD) angiographically documented. Plasma levels of Et-1 were determined in 34 type 2 diabetic patients with CAD (16 with stable angina, 6 with unstable angina, 12 with previous myocardial infarction) and in 19 nondiabetic patients with CAD (4 with stable angina, 5 with unstable angina, 10 with previous myocardial infarction). Fifteen diabetic patients without CAD and 9 healthy volunteers served as control subjec…