Search results for "Refraction"

showing 10 items of 200 documents

An Evanescent Field Optical Microscope

1989

We present a new form of optical microscope. An evanescent field is produced in the lower index medium of an ATR system and modulated by a sample deposited on the hypotenuse of the prism. A sharpened fiber optic probes this field and gives information about the topography of the surface.

MicroscopeMaterials scienceOptical fiberField (physics)business.industryRefractionlaw.inventionOptical axisOpticsOptical microscopelawPrismScanning tunneling microscopebusinessSPIE Proceedings
researchProduct

Changes in the objective amplitude of accommodation with pupil size.

2014

PURPOSE We evaluate the effect of pupil size on objectively measured amplitude of accommodation (AA). METHODS Pupil diameter and wavefront aberrometry were obtained in 15 eyes when stimulus swept across the range of clear vision in steps of 0.5 diopters. Wavefront refraction techniques were used to compute objective AA as the maximum refractive change. Measurements were obtained monocularly under low and high ambient room lighting conditions with a fixed luminance of the fixation target. Amplitude of accommodation computations were performed taking into account just paraxial rays (paraxial AA) or including the effects of the change of spherical aberration during accommodation (minRMS AA). R…

MiosisAdultMaleCorneal Wavefront AberrationLightRefraction OcularLuminancePupilCorneaYoung AdultOpticsmedicineHumansDioptrePhysicsbusiness.industryAberrometryParaxial approximationAccommodation OcularPupilAmplitude of accommodationOphthalmologySpherical aberrationFemalemedicine.symptombusinessAccommodationOptometryOptometry and vision science : official publication of the American Academy of Optometry
researchProduct

Multivariate geophysical survey to detect a shallow fault zone in a landfill project area

2018

An integrated analysis of 2D high-resolution shallow seismic refraction tomographies (SRT) and electrical resistivity tomographies (ERT) has been carried out along a slope where the presence of a fault zone was assumed. It was also applied a post-inversion k-means cluster analysis of the P-wave velocity, the density of the seismic rays and the electrical resistivity of the interpretation models. Distribution maps of the cluster in multi-space were built, allowing to better definethe lateral geometry of a NE-SW directed band composed of intensely tectonized carbonate breccias. Finally, the fracturing and kinematic analysis on fault planes observed along the trenches, highlighted systems of l…

Multivariate statisticsSettore GEO/02 - Geologia Stratigrafica E SedimentologicaSettore GEO/11 - Geofisica ApplicataGeophysical surveyProject areaSeimic refraction tomography Electrical resistivity tomography Cluster Analysis Fault BellolampoGeologySeismology
researchProduct

Reflection and Refraction of Singularities for Wave Equations with Interface Conditions given by Fourier Integral Operators

1992

Cauchy problems for hyperbolic operators often have the property, that the singularities of the initial data propagate along the bicharacteristic strips of the operator (cf. e.g. [13]). We consider, in the linear case, the situation where the bicharacteristics hit transversally a spacelike interface, which is ‘active’ in the sense that the interface condition is given via certain Fourier integral operators. Taking the identity, we obtain classical transmission conditions. A suitable functional analytic setting is furnished by the interaction concept [3], [6], [7], which covers very general mutual influences of evolution phenomena on different domains.

Operator (computer programming)Mathematical analysisRefraction (sound)Reflection (physics)Microlocal analysisCauchy distributionGravitational singularityWave equationFourier integral operatorMathematics
researchProduct

Acs refrakcija un viņas noteikšana

1933

Titullapā norādīts autors: Apiņš, Kārlis

OphthalmologyAcs refrakcijaRedze:MEDICINE [Research Subject Categories]AstigmatismsOftalmoskopijaAcu slimībasEye disordersOftalmoloģijaEye refraction
researchProduct

Power profiles in multifocal contact lenses with variable multifocal zone

2016

BACKGROUND The power profile of multifocal contact lenses has been demonstrated to report important information that could be used during the fitting process. The aim of this work is to describe the power profile of a recent set of gas permeable multifocal contact lenses as a function of the pupil radius. METHODS The measured multifocal contact lenses have a centre-distance design, and are available with five distance-vision diameters (XS, S, M, L and XL) and two different additions: Type A (up to +2.00 D) and Type B (up to +2.50 D). The optical device NIMO TR1504 (Lambda-X, Nivelles, Belgium) was used to obtain the power profile measurements. The optical lens power distribution as a functi…

Optical PhenomenaContact LensesApertureVisual AcuityRefraction Ocularlaw.invention03 medical and health sciencesNear vision0302 clinical medicineOpticslawHumansPhysicsbusiness.industryEquipment DesignPresbyopiaRadiusFunction (mathematics)Power (physics)Lens (optics)OphthalmologyVariable (computer science)030221 ophthalmology & optometrybusiness030217 neurology & neurosurgeryOptometryClinical and Experimental Optometry
researchProduct

Power Profiles and In Vitro Optical Quality of Scleral Contact Lenses: Effect of the Aperture and Power

2017

To assess the power profile and in vitro optical quality of scleral contact lenses with different powers as a function of the optical aperture. The mini and semiscleral contact lenses (Procornea) were measured for five powers per design. The NIMO TR-1504 (Lambda-X) was used to assess the power profile and Zernike coefficients of each contact lens. Ten measurements per lens were taken at 3- and 6-mm apertures. Furthermore, the optical quality of each lens was described in Zernike coefficients, modulation transfer function, and point spread function (PSF). A convolution of each lens PSF with an eye-chart image was also computed. The optical power fluctuated less than 0.5 diopters (D) along th…

Optics and PhotonicsMaterials scienceContact LensesAperturePhysics::OpticsOptical powerAstrophysics::Cosmology and Extragalactic AstrophysicsIn Vitro TechniquesRefraction Ocularlaw.invention03 medical and health sciences0302 clinical medicineOpticslawOptical transfer functionHumansDioptreAnalysis of Variancebusiness.industryLens speedEquipment DesignLens (optics)Contact lensOphthalmology030221 ophthalmology & optometryGradient-index opticsbusiness030217 neurology & neurosurgeryEye & Contact Lens: Science & Clinical Practice
researchProduct

Optical quality of rotationally symmetrical contact lenses derived from their power profiles.

2017

To present a methodology for evaluating the optical quality of rotationally symmetrical contact lenses (CLs) from a single power profile.Simulated rotationally symmetrical power profiles corresponding to different CLs designs (monofocal, two-zone center-near bifocal, and four-zone center-distance bifocal) were used to calculate the wavefront error profile by means of numerical integration. Then, each lens wavefront error profile was spun around the center to obtain the lens wavefront error surface. From the surface, monochromatic optical transfer functions (OTF), simulated images and the visual Strehl ratio based on the OTF (VSOTF) were obtained for different distances and pupil sizes (3 an…

Optics and PhotonicsMaterials sciencebusiness.industryContact LensesPupilGeneral MedicineEquipment DesignPresbyopiaModels TheoreticalRefraction Ocular01 natural sciencesOptical qualityPower (physics)010309 opticsContact lens03 medical and health sciencesOphthalmology0302 clinical medicineOptics0103 physical sciences030221 ophthalmology & optometryHumansbusinessOptometryContact lensanterior eye : the journal of the British Contact Lens Association
researchProduct

Statistical analysis when dealing with astigmatism: assessment of different spherocylindrical notations.

2001

Ophthalmic epidemiological studies frequently deal with ocular refractive errors, which are commonly expressed in the form sphere/cylinder x axis. However, this representation has been shown not to be the most suitable one for performing statistical analysis. Although alternative analytical and graphic methods to represent this kind of data have been developed, these formalisms have often gone unnoticed by researchers, despite their usefulness and versatility. Besides, there has been no discussion of how each of them fits in with a particular type of study. In this paper, several mathematical representations of dioptric power are revisited in a comprehensive way. The aim is to encourage res…

Optics and PhotonicsModels StatisticalEpidemiologybusiness.industrymedia_common.quotation_subjectAstigmatismAstigmatismmedicine.diseaseNotationRefraction OcularRotation formalisms in three dimensionsOphthalmologyData Interpretation StatisticalCalculusMedicineHumansStatistical analysisSimplicityRepresentation (mathematics)businessMathematicsmedia_commonOphthalmic epidemiology
researchProduct

In vitro optical quality comparison of 2 trifocal intraocular lenses and 1 progressive multifocal intraocular lens.

2015

Purpose To evaluate the optical quality of 3 multifocal intraocular lenses (IOLs): the Mini Well Ready progressive multifocal aspheric IOL, the AT LISA trifocal diffractive IOL, and the Finevision full diffractive trifocal IOL. Setting University of Valencia, Valencia, Spain. Design Experimental study. Methods An instrument designed for measuring real-time modulation transfer function (MTF) and IOL power was used to measure the optical quality of each IOL for 3.0 mm and 4.5 mm apertures. This instrument measures both sagittal and tangential MTFs. The optical quality of each IOL was evaluated with the MTF, through-focus MTF, defocus tolerance, Strehl ratio MTF, and relative percentage of lig…

Optics and PhotonicsOptical PhenomenaComputer sciencemedicine.medical_treatmentCataract ExtractionProsthesis DesignRefraction Ocular03 medical and health sciencesNear vision0302 clinical medicineLens Implantation IntraocularOptical transfer functionmedicineProsthesis designHumansLenses IntraocularStrehl ratioCataract surgeryMultifocal intraocular lensModels TheoreticalSensory SystemsOptical qualityOphthalmologyIntraocular lenses030221 ophthalmology & optometryOptometrySurgery030217 neurology & neurosurgeryJournal of cataract and refractive surgery
researchProduct