Search results for "Refractive errors"
showing 10 items of 57 documents
Repeatability of in vitro power profile measurements for multifocal contact lenses
2015
Abstract Purpose To evaluate the repeatability of an optical device (NIMO TR1504, Lambda-X, Belgium) for measuring multifocal contact lens power profiles. Methods The NIMO TR1504 was used to measure power profiles 30 times for each of 10 different contact lenses from 4 major companies. All contact lenses were labelled as −3 D for distance vision; half were for high addition and half for low addition. The optical zone in all measurements was set to 3-mm radius. For each lens, the median power profile and the residuals of the 30 measurements were calculated. The 95% confidence bands and two indices that summarize measurement errors were calculated: the repeatability limit and an index of repe…
Axial Length and Anterior Segment Alterations in Former Preterm Infants and Full-Term Neonates Analyzed With Scheimpflug Imaging.
2017
Purpose To compare the axial length and anterior segment alterations in preterm infants with and without retinopathy of prematurity with those of full-term infants. Methods The Wiesbaden Prematurity Study investigated 503 participants of former gestational age ≤32 weeks and gestational age ≥37 weeks now being aged 4 to 10 years. This study included 485 participants in the prospective controlled cross-sectional, hospital-based study with successful Pentacam Scheimpflug imaging. Anterior segment parameters, axial length measurements, and associated factors were analyzed. Results Corneal thickness did not differ between former preterm and full-term infants. Significant differences were found b…
Visual and optical performance with hybrid multifocal intraocular lenses
2010
During the past years, the wish to become independent of spectacles has been growing among cataract and presbyopic patients due to many factors, such as the increase in near visual demands, the aesthetic need for a spectacle-free image and ageing of refractive surgery patients, among others. This review assesses recently published studies that analyse visual and optical performance through different metrics of eyes implanted with multifocal intraocular lenses (IOLs), particularly hybrid IOL designs. The published evidence suggests that hybrid multifocal IOLs provide very good outcomes in a number of visual and optical performance parameters. Patients implanted with this type of IOL obtain a…
Graphic representation of data resulting from measurement comparison trials in cataract and refractive surgery.
2003
* BACKGROUND AND OBJECTIVES: The evaluation of new diagnostic measurement devices allows intraindividual comparison with an established standard method. However, reports in journal articles often omit the adequate incorporation of the intraindividual design into the graphic representation. * PATIENTS AND METHODS: This article illustrates the drawbacks and the possible erroneous conclusions caused by this misleading practice in terms of recent method comparison data resulting from axial length measurement in 220 consecutive patients by both applanation ultrasound and partial coherence interferometry. * RESULTS: Graphic representation of such method comparison data should be based on boxplots…
Childhood gene-environment interactions and age-dependent effects of genetic variants associated with refractive error and myopia: The CREAM Consorti…
2018
Myopia, currently at epidemic levels in East Asia, is a leading cause of untreatable visual impairment. Genome-wide association studies (GWAS) in adults have identified 39 loci associated with refractive error and myopia. Here, the age-of-onset of association between genetic variants at these 39 loci and refractive error was investigated in 5200 children assessed longitudinally across ages 7-15 years, along with gene-environment interactions involving the major environmental risk-factors, nearwork and time outdoors. Specific variants could be categorized as showing evidence of: (a) early-onset effects remaining stable through childhood, (b) early-onset effects that progressed further with i…
Visual quality with corneo-scleral contact lenses after intracorneal ring segment (ICRS) implantation for keratoconus management
2019
Purpose: To evaluate the visual quality results when fitting a corneo-scleral contact lens (CScL) after intracorneal ring segment (ICRS) implantation for keratoconus management. Methods: Twenty-seven eyes of 27 patients with keratoconus underwent ICRS implantation and had CScL fitted as their visual quality was unsatisfactory with their spectacles or contact lenses. Patients received a complete eye examination, refraction and visual acuity assessment, anterior eye biomicroscopy, ocular fundus examination, corneal topographic analysis, endothelial-cell count, and visual quality assessment using contrast sensitivity and aberrometry tests. A diagnostic trial set was used in the fitting process…
Age-related changes in the human visual system and prevalence of refractive conditions in patients attending an eye clinic.
2008
PURPOSE: To retrospectively report the trends of change in several parameters of the human visualsystem over a wide age range in patients attending an eye clinic. SETTING: University of Valencia, Valencia, Spain. METHODS: The clinical records of 2654 patients were retrospectively reviewed, and the age, sex, spherocylindrical refraction, visual acuity, keratometry, and intraocular pressure were obtained. Descriptive values for each parameter and the correlations with age and between different parameters were calculated. Vectorial components of refraction, including blur, were also derived from clinical refractive data and then analyzed. RESULTS: Several parameters changed significantly with …
No evidence for an association of plasma homocysteine levels and refractive error – Results from the population-based Gutenberg Health Study (GHS)
2020
Purpose There is a strong association between severe hyperhomocysteinemia and myopia. Thus we studied the hypothesis that even moderately increased levels of homocysteine (Hcy) might be a potentially treatable risk factor for myopia. Methods The Gutenberg Health Study (GHS) is a population-based, prospective, observational cohort study in Germany, including 15,010 participants aged between 35 and 74 at recruitment. The baseline examination was conducted from 2007–2012. Refraction was measured using autorefraction (HARK 599, Carl Zeiss AG, Jena, Germany). Hcy was measured by an immunoassay. We included only phakic participants without a history of corneal surgery or corneal laser treatment. …
Visual acuity tolerance to residual refractive errors in patients with an apodized diffractive intraocular lens.
2007
To assess visual acuity tolerance to defocus caused by residual refractive errors after clear lens extraction (CLE) with apodized diffractive intraocular lens (IOL) implantation.Fernández-Vega Ophthalmological Institute, Oviedo, Spain.In this prospective study, 150 eyes of 75 consecutive patients who had bilateral CLE with implantation of an AcrySof ReSTOR Natural IOL (Alcon) were evaluated. The eyes were divided into 2 groups: myopia and hyperopia. Residual refractive errors were analyzed using vector analysis. Monocular and binocular uncorrected distance visual acuity, best corrected distance visual acuity, uncorrected distance near visual acuity, and best distance-corrected near visual a…
Disability-related-distress in primary school learners with vision impairment due to uncorrected refractive error in KwaZulu-Natal Province, South Af…
2020
Background Uncorrected refractive error (URE) is a major cause of vision impairment among children that impacts negatively on their lives including distresses. We aim to understand the disability-related distress among vision-impaired children due to URE in rural and semi-rural South Africa using qualitative techniques. Methods Structured focus groups of children (aged 5-12 years old) with normal vision and vision impairment due to URE from four schools in Pinetown, KwaZulu Natal, South Africa, were performed (four mixed-gender group discussions and eight single gender group discussions). We recruited the study participants after the children underwent standardised vision screening. Criteri…