Search results for "Refractive"
showing 10 items of 559 documents
Graphic representation of data resulting from measurement comparison trials in cataract and refractive surgery.
2003
* BACKGROUND AND OBJECTIVES: The evaluation of new diagnostic measurement devices allows intraindividual comparison with an established standard method. However, reports in journal articles often omit the adequate incorporation of the intraindividual design into the graphic representation. * PATIENTS AND METHODS: This article illustrates the drawbacks and the possible erroneous conclusions caused by this misleading practice in terms of recent method comparison data resulting from axial length measurement in 220 consecutive patients by both applanation ultrasound and partial coherence interferometry. * RESULTS: Graphic representation of such method comparison data should be based on boxplots…
Absorption and Scattering Microscopy of Single Metal Nanoparticles.
2006
Several recently developed detection techniques opened studies of individual metal nanoparticles (1-100 nm in diameter) in the optical far field. Eliminating averaging over the broad size and shape distributions produced by even the best of current synthesis methods, these studies hold great promise for gaining a deeper insight into many of the properties of metal nanoparticles, notably electronic and vibrational relaxation. All methods are based on detection of a scattered wave emitted either by the particle itself, or by its close environment. Direct absorption and interference techniques rely on the particle's scattering and have similar limits in signal-to-noise ratio. The photothermal …
Weld pool surface temperature measurement from polarization state of thermal emission
2014
This paper presents a passive polarimetry method using a division of aperture optical device in order to measure the temperature distribution at the weld pool surface. Thermal emission from a hot liquid metal was investigated at a near-infrared wavelength corresponding to a blind spectral window of a helium plasma generated during gas tungsten arc welding process. The refractive index of liquid metal and the surface radiance are deduced from the polarisation state of thermal emissions. Based upon the knowledge of both characteristics, the temperature distribution can be calculated. Conseil Régional de Bourgogne
Self Calibrating Nano-Ruler
2012
The aim of a nanoruler is to measure distances on a length scale in the order of nanometers. This concept can be realized by two plasmonic nanoparticles (usually spheres), which are placed within a short distance to each other. Since the plasmon modes of both particles are coupled, they influence each other along the interparticle axis (i.e. longitudinal plasmon mode, resulting in a shift of the resonance wavelength compared to the single particle. Because the resulting resonance wavelength depends on the interparticle distance, the spectral investigation of such a dimer allows the determination of the interparticle distance.
Toward a wave turbulence formulation of statistical nonlinear optics
2012
International audience; During this last decade, several remarkable phenomena inherent to the nonlinear propagation of incoherent optical waves have been reported in the literature. This article is aimed at providing a generalized wave turbulence kinetic formulation of random nonlinear waves governed by the nonlinear Schrodinger equation in the presence of a nonlocal or a noninstantaneous nonlinear response function. Depending on the amount of nonlocal (noninstantaneous) nonlinear interaction and the amount of inhomogeneous (nonstationary) statistics of the incoherent wave, different types of kinetic equations are obtained. In the spatial domain, when the incoherent wave exhibits fluctuatio…
Childhood gene-environment interactions and age-dependent effects of genetic variants associated with refractive error and myopia: The CREAM Consorti…
2018
Myopia, currently at epidemic levels in East Asia, is a leading cause of untreatable visual impairment. Genome-wide association studies (GWAS) in adults have identified 39 loci associated with refractive error and myopia. Here, the age-of-onset of association between genetic variants at these 39 loci and refractive error was investigated in 5200 children assessed longitudinally across ages 7-15 years, along with gene-environment interactions involving the major environmental risk-factors, nearwork and time outdoors. Specific variants could be categorized as showing evidence of: (a) early-onset effects remaining stable through childhood, (b) early-onset effects that progressed further with i…
Visual quality with corneo-scleral contact lenses after intracorneal ring segment (ICRS) implantation for keratoconus management
2019
Purpose: To evaluate the visual quality results when fitting a corneo-scleral contact lens (CScL) after intracorneal ring segment (ICRS) implantation for keratoconus management. Methods: Twenty-seven eyes of 27 patients with keratoconus underwent ICRS implantation and had CScL fitted as their visual quality was unsatisfactory with their spectacles or contact lenses. Patients received a complete eye examination, refraction and visual acuity assessment, anterior eye biomicroscopy, ocular fundus examination, corneal topographic analysis, endothelial-cell count, and visual quality assessment using contrast sensitivity and aberrometry tests. A diagnostic trial set was used in the fitting process…
Age-related changes in the human visual system and prevalence of refractive conditions in patients attending an eye clinic.
2008
PURPOSE: To retrospectively report the trends of change in several parameters of the human visualsystem over a wide age range in patients attending an eye clinic. SETTING: University of Valencia, Valencia, Spain. METHODS: The clinical records of 2654 patients were retrospectively reviewed, and the age, sex, spherocylindrical refraction, visual acuity, keratometry, and intraocular pressure were obtained. Descriptive values for each parameter and the correlations with age and between different parameters were calculated. Vectorial components of refraction, including blur, were also derived from clinical refractive data and then analyzed. RESULTS: Several parameters changed significantly with …
Genome-wide association study for refractive astigmatism reveals genetic co-determination with spherical equivalent refractive error: the CREAM conso…
2015
To identify genetic variants associated with refractive astigmatism in the general population, meta-analyses of genome-wide association studies were performed for: White Europeans aged at least 25 years (20 cohorts, N = 31,968); Asian subjects aged at least 25 years (7 cohorts, N = 9,295); White Europeans aged <25 years (4 cohorts, N = 5,640); and all independent individuals from the above three samples combined with a sample of Chinese subjects aged <25 years (N = 45,931). Participants were classified as cases with refractive astigmatism if the average cylinder power in their two eyes was at least 1.00 diopter and as controls otherwise. Genome-wide association analysis was carried out for …
No evidence for an association of plasma homocysteine levels and refractive error – Results from the population-based Gutenberg Health Study (GHS)
2020
Purpose There is a strong association between severe hyperhomocysteinemia and myopia. Thus we studied the hypothesis that even moderately increased levels of homocysteine (Hcy) might be a potentially treatable risk factor for myopia. Methods The Gutenberg Health Study (GHS) is a population-based, prospective, observational cohort study in Germany, including 15,010 participants aged between 35 and 74 at recruitment. The baseline examination was conducted from 2007–2012. Refraction was measured using autorefraction (HARK 599, Carl Zeiss AG, Jena, Germany). Hcy was measured by an immunoassay. We included only phakic participants without a history of corneal surgery or corneal laser treatment. …