Search results for "Relative Humidity"
showing 10 items of 156 documents
Comparing different profiles to characterize the atmosphere for three MODIS TIR bands
2015
Abstract Accurate land surface temperature (LST) retrievals from sensors aboard orbiting satellites are dependent on the corresponding atmospheric correction, especially in the thermal infrared (TIR) spectral domain (8–14 μm). To remove the atmospheric effects from at-sensor measured radiance in the TIR range it is needed to characterize the atmosphere by means of three specific variables: the upwelling path and the hemispherical downwelling radiances plus the atmospheric transmissivity. Those variables can be derived from the previous knowledge of vertical atmospheric profiles of air temperature and relative humidity at different geo-potential heights and pressures. In this work, the above…
Retrieval of characteristic parameters for water vapour transmittance in the development of ground based Sun-Sky radiometric measurements of columnar…
2014
Abstract. Sun–sky radiometers are instruments created for aerosol study, but they can measure in the water vapour absorption band allowing the estimation of columnar water vapour in clear sky simultaneously with aerosol characteristics, with high temporal resolution. A new methodology is presented for estimating calibration parameters (i.e. characteristic parameters of the atmospheric transmittance and solar calibration constant) directly from the sun–sky radiometer measurements. The methodology is based on the hypothesis that characteristic parameters of the atmospheric transmittance are dependent on vertical profiles of pressure, temperature and moisture occurring at each site of measurem…
The Properties of Atmospheric Aerosol Particles as Functions of the Relative Humidity at Thermodynamic Equilibrium with the Surrounding Moist Air
1976
Publisher Summary The chapter addresses the problems in aerosol measuring techniques and selection of sampling and measuring methods. Theoretic evaluation of mass, size, mean density, and mean refractive index as functions of the relative humidity is discussed. The chapter also discusses techniques for measuring the mass as a function of the relative humidity; determination of the mean density; and measuring the mean complex index of refraction. Results of the measurements, discussion of the results, coefficients of mass increase, mean densities and real parts of the mean complex index of refractions, and applicability of the results are also described. Finally, the chapter then reviews the…
2015
In 2011, the MOZAIC (Measurement of Ozone by AIRBUS In-Service Aircraft) successor programme IAGOS (In-service Aircraft for a Global Observing System) started to equip their long-haul passenger aircraft with the modified capacitive hygrometer Vaisala HUMICAP ® of type H. The assurance of the data quality and the consistency of the data set during the transition from MOZAIC Capacitive Hygrometers to IAGOS Capacitive Hygrometers were evaluated within the CIRRUS-III and AIRTOSS-ICE field studies. During these performance tests, the capacitive hygrometers were operated aboard a Learjet 35A aircraft together with a closed-cell Lyman-α fluorescence hygrometer, an open-path tunable diode laser (TD…
2021
Abstract. Homogeneous freezing of aqueous solution aerosol particles is an important process for cloud ice formation in the upper troposphere. There the air temperature is low, the ice supersaturation can be high and the concentration of ice-nucleating particles is too low to initiate and dominate cirrus cloud formation by heterogeneous ice nucleation processes. The most common description to quantify homogeneous freezing processes is based on the water activity criterion (WAC) as proposed by Koop et al. (2000). The WAC describes the homogeneous nucleation rate coefficients only as a function of the water activity, which makes this approach well applicable in numerical models. In this study…
Absolute Humidity Influences the Seasonal Persistence and Infectivity of Human Norovirus
2014
ABSTRACT Norovirus (NoV) is one of the main causative agents of acute gastroenteritis worldwide. In temperate climates, outbreaks peak during the winter season. The mechanism by which climatic factors influence the occurrence of NoV outbreaks is unknown. We hypothesized that humidity is linked to NoV seasonality. Human NoV is not cultivatable, so we used cultivatable murine norovirus (MNV) as a surrogate to study its persistence when exposed to various levels of relative humidity (RH) from low (10% RH) to saturated (100% RH) conditions at 9 and 25°C. In addition, we conducted similar experiments with virus-like particles (VLPs) from the predominant GII-4 norovirus and studied changes in bin…
Prediction of conidial germination of Penicillium chrysogenum as influenced by temperature, water activity and pH.
2001
M. SAUTOUR, A. ROUGET, P. DANTIGNY, C. DIVIES AND M. BENSOUSSAN. 2001 Aims: Conidial germination of Penicillium chrysogenum was carried out under operating conditions compatible with a pastries manufacturing process. Methods and Results: A range, limited by two experimental values, was defined for each environmental factor tested: temperature (15 or 25°C), water activity (0·75 or 0·85) and pH (3·5 or 5·5). A closed device was made, which maintained an equilibrium between water activity of the culture medium and atmospheric relative humidity during 25 days, to follow spore germination. The combined effects of temperature, water activity and pH on spore germination were studied by applying fa…
Water vapour permeability, thermal and wetting properties of whey protein isolate based edible films
2010
Abstract This study deals with the effect of whey protein isolate (WPI) and glycerol (GLY) used as a plasticizer on some physical properties of cast whey protein isolate (WPI) films. Films were prepared from heated (80 °C for 30 min) aqueous solutions of WPI at 7, 8, 9 and 10% (w/w), GLY (40%, w/w, of WPI) and WPI at 8% (w/w), GLY (30, 40, and 60%, w/w, of WPI). For all types of films, water vapour permeability for four relative humidity differentials (30–100%, 30–84%, 30–75%, and 30–53%), surface and thermal properties were measured. Varying the proportion of WPI and GLY in edible films had some effect on water vapour permeability, wetting and thermal properties of WPI films. A cumulative …
Hydration and dehydration kinetics of xylazine hydrochloride
2009
From the experiments where mixture of xylazine hydrochloride hydrate H and anhydrous X were held at constant conditions, the stable form of xylazine hydrochloride can be found out. To determine equilibrium relative humidity, the unstable form of xylazine hydrochloride was inserted in thermostated humidity chamber and its weight was recorded by weighing the sample outside the chamber. The kinetic model and the rate constant for each condition were determined. The rate constants give information regarding the speed of the process at every experimentally used relative humidity. Thus using the data in coordinates k – p for each temperature it is possible to determine the water vapor pressure of…
A case study on the formation and evolution of ice supersaturation in the vicinity of a warm conveyor belt\'s outflow region
2005
A case study is presented on the formation and evolution of an ice-supersaturated region (ISSR) that was detected by a radiosonde in NE Germany at 06:00 UTC 29 November 2000. The ISSR was situated in the vicinity of the outflow region of a warm conveyor belt associated with an intense event of cyclogenesis in the eastern North Atlantic. Using ECMWF analyses and trajectory calculations it is determined when the air parcels became supersaturated and later subsaturated again. In the case considered, the state of air parcel supersaturation can last for longer than 24h. The ISSR was unusually thick: while the mean vertical extension of ISSRs in NE Germany is about 500m, the one investigated here…