Polychromatic Cherenkov radiation and supercontinuum in tapered optical fibers
2012
We numerically demonstrate that bright solitons in tapered optical fibers can emit polychromatic Cherenkov radiation providing they remain spectrally close to the zero dispersion wavelength during propagation along the fiber. The prime role in this phenomenon is played by the soliton self-frequency shift driving efficiency of the radiation and tuning of its frequency. Depending on tapering and input pulse power, the radiation is emitted either as a train of pulses at different frequencies or as a single temporally broad and strongly chirped pulse.
Multi-peak-spectra generation with Cherenkov radiation in a non-uniform single mode fiber
2014
We propose, by means of numerical simulations, a simple method to design a non-uniform standard single mode fiber to generate spectral broadening in the form of "ad-hoc" chosen peaks from dispersive waves. The controlled multi-peak generation is possible by an on/off switch of Cherenkov radiation, achieved by tailoring the fiber dispersion when decreasing the cladding diameter by segments. The interplay between the fiber dispersion and the soliton self-frequency shift results in discrete peaks of efficiently emitted Cherenkov radiation from low order solitons, despite the small amount of energy contained in a pulse. These spectra are useful for applications that demand low power bell-shaped…
Parameter Degeneracy in Flavor-Dependent Reconstruction of Supernova Neutrino Fluxes
2008
We reexamine the possibility of reconstructing the initial fluxes of supernova neutrinos emitted in a future core-collapse galactic supernova explosion and detected in a Megaton-sized water Cherenkov detector. A novel key element in our method is the inclusion, in addition to the total and the average energies of each neutrino species, of a "pinching" parameter characterizing the width of the distribution as a fit parameter. We uncover in this case a continuous degeneracy in the reconstructed parameters of supernova neutrino fluxes at the neutrinosphere. We analyze in detail the features of this degeneracy and show how it occurs irrespective of the parametrization used for the distribution …
Status of the PANDA Barrel DIRC
2014
The PANDA experiment at the future Facility for Antiproton and Ion Research in Europe GmbH (FAIR) at GSI, Darmstadt will study fundamental questions of hadron physics and QCD using high-intensity cooled antiproton beams with momenta between 1.5 and 15 GeV/c. Hadronic PID in the barrel region of the PANDA detector will be provided by a DIRC (Detection of Internally Reflected Cherenkov light) counter. The design is based on the successful BABAR DIRC with several key improvements, such as fast photon timing and a compact imaging region. Detailed Monte Carlo simulation studies were performed for DIRC designs based on narrow bars or wide plates with a variety of focusing solutions. The performan…
The Barrel DIRC of PANDA
2012
Cooled antiproton beams of unprecedented intensities in the momentum range of 1.5-15 GeV/c will be used for the PANDA experiment at FAIR to perform high precision experiments in the charmed quark sector. The PANDA detector will investigate antiproton annihilations with beams in the momentum range of 1.5 GeV/c to 15 GeV/c on a fixed target. An almost 4π acceptance double spectrometer is divided in a forward spectrometer and a target spectrometer. The charged particle identification in the latter is performed by ring imaging Cherenkov counters employing the DIRC principle.
2021
Abstract The present article summarizes the results of a study of optical Cherenkov radiation (ChR) spectral properties both theoretically and experimentally. This type of radiation has a continuous spectral distribution which allows to use it in different fields of physics as for charged particle identification or generation of intense THz radiation. By exploiting the frequency dependency of the target permittivity it is possible to observe quasi–monochromatic radiation. A theoretical model based on a surface current approach is presented which allows to predict angular and spectral properties of ChR. In order to test the model predictions, an experiment was carried out using 855 MeV elect…
The antares neutrino detector instrumentation
2012
ANTARES is actually the fully operational and the largest neutrino telescope in the Northern hemisphere. Located in the Mediterranean Sea, it consists of a 3D array of 885 photomultiplier tubes (PMTs) arranged in 12 detection lines (25 storeys each), able to detect the Cherenkov light induced by upgoing relativistic muons produced in the interaction of high energy cosmic neutrinos with the detector surroundings. Among its physics goals, the search for neutrino astrophysical sources and the indirect detection of dark matter particles coming from the sun are of particular interest. To reach these goals, good accuracy in track reconstruction is mandatory, so several calibration systems for tim…
2021
Abstract IceCube is a cubic-kilometer Cherenkov telescope operating at the South Pole. The main goal of IceCube is the detection of astrophysical neutrinos and the identification of their sources. High-energy muon neutrinos are observed via the secondary muons produced in charge current interactions with nuclei in the ice. Currently, the best performing muon track directional reconstruction is based on a maximum likelihood method using the arrival time distribution of Cherenkov photons registered by the experiment's photomultipliers. A known systematic shortcoming of the prevailing method is to assume a continuous energy loss along the muon track. However at energies >1 TeV the light yie…
Deep sea tests of a prototype of the KM3NeT digital optical module: KM3NeT Collaboration
2014
The first prototype of a photo-detection unit of the future KM3NeT neutrino telescope has been deployed in the deep waters of the Mediterranean Sea. This digital optical module has a novel design with a very large photocathode area segmented by the use of 31 three inch photomultiplier tubes. It has been integrated in the ANTARES detector for in-situ testing and validation. This paper reports on the first months of data taking and rate measurements. The analysis results highlight the capabilities of the new module design in terms of background suppression and signal recognition. The directionality of the optical module enables the recognition of multiple Cherenkov photons from the same $^{40…
A Disc-DIRC Cherenkov detector with high resolution micro channel plate photomultiplier tubes
2014
The upcoming PANDA Experiment at FAIR in Germany will be equipped with a novel Cherenkov detector type for high-energy particle identification. This very compact Disc-DIRC detector uses a large disc-shaped fused silica plate of 2 cm thickness as its Cherenkov radiator. The internally reflected Cherenkov light is transported to the rim of the disc where it is focused by quartz light guides onto microchannel plate photomultiplier tubes (MCP-PMTs) with high spatial resolution (pitch 0.5 mm) and high time resolution (σ ≈ 100 ps). The device has an active area of about 3 m2 and will be able to identify pions and kaons with a separation power of more than 3σ in the momentum range up to 4 GeV/c. I…