Search results for "Repair"

showing 7 items of 747 documents

DNA integrity in diagnosis of premalignant lesions

2020

Background Carcinogenesis is a dynamic process which traditional biopsying can not keep up with. Saliva as fluid in the vicinity of the tumor can offer better insights to this process. This study aimed to identify the accuracy of salivary DNA integrity index in differentiating between oral premalignant lesions and oral cancer. Material and Methods This phase II diagnostic test accuracy study included 93 patients divided into three groups: 30 oral cancer patients, 33 patients with oral premalignant lesions divided into 21 oral lichen planus patients and 12 patients with leukoplakia and 30 normal individuals who acted as controls. Oral rinse was collected from all participants and they all un…

squamous cell carcinomaSalivamedicine.medical_specialtymedicine.disease_causeGastroenterologysurvivalstomatognathic systemmismatch repair endonuclease pms2Oral Cancer and Potentially malignant disordersInternal medicinePositive predicative valuemedicineHumansSalivaGeneral DentistryUNESCO:CIENCIAS MÉDICASLeukoplakiaDna integrityDiagnostic Tests Routinebusiness.industryResearchmouth neoplasmsSignificant differenceCancerDNAmedicine.diseasestomatognathic diseasesOtorhinolaryngologySurgeryOral lichen planusLeukoplakia OralbusinessCarcinogenesisLichen Planus Oral
researchProduct

Wewnątrznaczyniowe dwuetapowe leczenie tętniaków aorty brzusznej z użyciem Heli-FX EndoAnchor System

2019

Wstęp: Wyniki leczenia tętniaków aorty brzusznej mimo wprowadzenia nowych technik wewnątrznaczyniowych nadal nie zawsze są zadowalające. Szczególnie trudną grupą pacjentów są osoby z krótką oraz stożkową szyją. W tej grupie chorych często występuje w okresie pooperacyjnym przeciek typu I. Jedną z metod mających temu powikłaniu zapobiec jest zastosowanie wkrętów wewnątrznaczyniowych Heli-FX. Ma to zwiększyć przyleganie systemu stentgraftu do ściany aorty brzusznej oraz zapobiec jego ewentualnej migracji. Materiał i metody: Autorzy niniejszego artykułu proponują zastosowanie leczenia dwuetapowego. Pierwszy etap stanowiła implantacja przedłużki aortalnej tuż poniżej odejścia tętnic nerkowych i…

stent-grafttętniak aorty brzusznejendoanchorstrudna szyja tętniakaendovascular proceduresstentgraft aortalnywkręty wewnątrznaczynioweaortic aneurysmhostile neckendovascular aortic repairChirurgia Polska
researchProduct

Periscope endograft technique to revascularize the left subclavian artery during thoracic endovascular aortic repair.

2013

Purpose: To present early and midterm results of the periscope endograft (PG) technique to maintain left subclavian artery (LSA) blood flow in thoracic endovascular aortic repairs (TEVAR) involving zone 3. Methods: From April 2010 to January 2013, 14 consecutive high-risk patients (11 men; mean age 7068 years, range 56–87) underwent TEVAR with the PG technique for 10 thoracic aortic aneurysms (TAA), 2 traumatic aortic ruptures, and 2 aortic dissections without a suitable landing zone (.2 cm distal to the LSA). Five procedures were performed emergently for rupture (3 TAAs and the 2 trauma cases). Two patients had a periscope deployed in an aberrant right subclavian artery. The periscope endo…

thoracic aorta thoracic aortic aneurysm dissection arch aneurysm thoracic endovascular aortic repair stent-graft left subclavian artery periscope graft deployment technique proximal landing zoneSettore MED/22 - Chirurgia Vascolare
researchProduct

Pęknięty tętniak aorty zstępującej - duże wyzwanie dla niedużego ośrodka chirurgii naczyniowej

2018

Pacjentka, lat 76, została skierowana do Uniwersyteckiego Szpitala Klinicznego w Opolu z powodu podejrzenia rozwarstwienia aorty wstępującej i tamponady osierdzia. Przy przyjęciu chora w stanie ogólnym skrajnie ciężkim, z objawami głębokiego wstrząsu, niestabilna hemodynamicznie oraz wentylowana mechanicznie. W wykonanym doraźnie badaniu angio-TK stwierdzono rozwarstwienie aorty zstępującej z pękniętym tętniakiem w jej środkowym i dolnym odcinku oraz duży krwiak lewej jamy opłucnowej. Ze względu na znaczną szerokość aorty zstępującej, nawet w jej początkowym odcinku oraz aorty brzusznej powyżej pnia trzewnego do zaopatrzenia tętniaka potrzebne są dwa elementy stentgraftów o średnicy 46 mm. …

thoracic endovascular aortic repairtętniak aorty piersiowejaortic rupturethoracic aortic aneurysmaortic stent-graftstentgraft aortalnyhypovolemic shockwstrząs krwotocznyChirurgia Polska
researchProduct

A Time-Non-Homogeneous Double-Ended Queue with Failures and Repairs and Its Continuous Approximation

2018

We consider a time-non-homogeneous double-ended queue subject to catastrophes and repairs. The catastrophes occur according to a non-homogeneous Poisson process and lead the system into a state of failure. Instantaneously, the system is put under repair, such that repair time is governed by a time-varying intensity function. We analyze the transient and the asymptotic behavior of the queueing system. Moreover, we derive a heavy-traffic approximation that allows approximating the state of the systems by a time-non-homogeneous Wiener process subject to jumps to a spurious state (due to catastrophes) and random returns to the zero state (due to repairs). Special attention is devoted to the cas…

time-non-homogeneous jump-diffusion processesComputer scienceGeneral Mathematicsdouble-ended queues01 natural sciencestransition densitiesdouble-ended queues; time-non-homogeneous birth-death processes; catastrophes; repairs; transient probabilities; periodic intensity functions; time-non-homogeneous jump-diffusion processes; transition densities; first-passage-time010104 statistics & probabilitysymbols.namesakeZero state responseWiener processrepairsComputer Science (miscellaneous)Applied mathematicstime-non-homogeneous birth-death processes0101 mathematicsSpurious relationshipEngineering (miscellaneous)Queuefirst-passage-timeQueueing theorytransient probabilitieslcsh:Mathematics010102 general mathematicslcsh:QA1-939catastrophesperiodic intensity functionssymbolsDouble-ended queueFirst-hitting-time modelConstant (mathematics)Mathematics; Volume 6; Issue 5; Pages: 81
researchProduct

Analysis of corrective feedback in a multilingual classroom context from a CLIL perspective.

2017

Esta tesis doctoral analiza el feedback correctivo en una clase plurilingüe desde una perspectiva CLIL. El objetivo de este estudio es examinar el feedback que tiende a ser utilizado cuando se corrigen los errores orales en clase comparando diferentes asignaturas, todas ellas impartidas en lengua inglesa. Para ello se analiza la relación entre tipos de feedback y tipos de errores en diferentes asignaturas. Lo que se intenta averiguar es qué estrategias normalmente se eligen para corregir, qué tipo de error es el más frecuente y si hay alguna relación entre tipo de error, el feedback utilizado y la asignatura. Para el estudio se realizaron grabaciones de las clases con video cámara. Las asig…

types of errorsclassrroom discourse analysistypes of correctionEFL teachingUNESCO::LINGÜÍSTICA:LINGÜÍSTICA [UNESCO]cliluptakerepairerrorsanalysis of corrective feedbackcorrectionteacher´s confirmation
researchProduct

TENSION FREE CYSTOCELE REPAIR. FOUR YEARS FOLLOW-UP

2003

Aims of study: Anterior vaginal wall descensus is one of the most frequent alteration in patients with pelvic defects. At least 50% of women that had delivered two or more times presented a certain degree of this pathologic alteration of the anatomy, even thought only 10-20% of the patients complained of associated pains. The use of synthetic biocompatible materials has become more common in gynecology surgery(1)-(3). Polypropylene mesh to be proposed as a mean of surgical correction of moderate severe cystocele (Cervigni 1998)(2) Methods: 97 patients aged 42-75, parity 1-5, body weight 45-90, menopause 41 pts. (61%).Irritative sintoms( nocturia, frequency, urgency, dysuria and urge inconti…

vaginal wall descensus TENSION FREE CYSTOCELE REPAIR pelvic defectsSettore MED/40 - Ginecologia E Ostetricia
researchProduct