Search results for "Repeatability"

showing 10 items of 214 documents

Simultaneous detection of three antiviral and four antibiotic compounds in source-separated urine with liquid chromatography

2013

An analytical method for the simultaneous screening of three antiviral agents (nevirapine, zidovudine, lamivudine), four antibiotics (sulfamethoxazole, trimethoprim, ciprofloxacin, rifampicin) and one reference compound (carbamazepine) in human urine was developed. Separation was achieved with a Kinetex XB-C18 (75 × 4.6 mm, 2.6 μm) column after the extraction of pharmaceuticals from urine with SPE. Gradient elution with a mobile phase consisting of acetonitrile and 10 mM KH2 PO4 (pH 2.5), and diode array detection with monitoring at 210 and 264 nm was applied. The developed method was validated in terms of selectivity, linearity, stability and sensitivity. Repeatability (n = 3) and between-…

Detection limitChromatographyChemistryExtraction (chemistry)Filtration and SeparationRepeatabilityUrineHigh-performance liquid chromatographyTrimethoprimAnalytical ChemistryWastewatermedicineSolid phase extractionmedicine.drugJournal of Separation Science
researchProduct

Near infrared determination of Diuron in pesticide formulations

2005

Abstract A simple, fast and environmentally friendly near infrared (NIR)-based methodology was developed for Diuron determination in pesticide formulations. This methodology was based on the pesticide extraction with acetonitrile and subsequent transmittance measurement determination by peak area measurement between 2021 and 2047 nm, corrected with a single point baseline established at 2071 nm. The repeatability, as relative standard deviation of five independent analysis of a 15.3 mg g −1 Diuron standard was 0.03% and the limit of detection 0.013 mg g −1 . The reagent consumption was clearly reduced in front of a chromatographic reference procedure from 39.1 ml acetonitrile per sample, re…

Detection limitChromatographyChemistryNear-infrared spectroscopyExtraction (chemistry)Analytical chemistryRepeatabilityBiochemistryFourier transform spectroscopyAnalytical Chemistrychemistry.chemical_compoundReagentEnvironmental ChemistrySample preparationAcetonitrileSpectroscopyAnalytica Chimica Acta
researchProduct

A rapid and sensitive gas chromatography-mass spectrometry method for the quality control of perfumes: simultaneous determination of phthalates

2013

A rapid and sensitive analytical gas chromatography-mass spectrometry (GC-MS) method for perfume analysis to determine the phthalates banned by the European Union Regulation on cosmetic samples is presented. This method has been tested in commercial alcoholic perfume samples for the determination of the following seven phthalates: dibutyl phthalate, bis(2-ethylhexyl) phthalate, bis(2-methoxyethyl) phthalate, n-pentyl-isopentylphthalate, di-n-pentyl phthalate, diisopentylphthalate and benzyl butyl phthalate. Sample evaporation and redissolution in ethanol is carried out before GC-MS analysis, with no dilution of the sample. External calibration and standard addition calibration are compared …

Detection limitChromatographyDibutyl phthalateGeneral Chemical EngineeringGeneral EngineeringPhthalateRepeatabilityAnalytical Chemistrychemistry.chemical_compoundchemistryBenzyl butyl phthalateStandard additionmedia_common.cataloged_instanceEuropean unionGas chromatography–mass spectrometrymedia_commonAnal. Methods
researchProduct

Determination of cyromazine in pesticide commercial formulations by vibrational spectrometric procedures

2004

Two vibrational spectrometry-based methodologies were developed for Cyromazine determination in solid pesticide formulations: a Fourier transform infrared (FTIR) procedure, based on the extraction of Cyromazine by CH3OH and direct determination in the extracts by peak height measurement at 1622 cm−1 corrected using a baseline defined at 1900 cm−1, and a FT-Raman determination, made directly on the powdered solid products using standard chromatographic glass vials as sample cells and measuring the Raman intensity between 633 and 623 cm−1 for a baseline established between 663 and 601 cm−1. The sensitivity obtained was 0.01631 absorbance g−1 mg for FTIR determination and 2.23 area values g−1 …

Detection limitChromatographyExtraction (chemistry)Analytical chemistryRepeatabilityCyromazineBiochemistryFourier transform spectroscopyAnalytical ChemistryAbsorbancechemistry.chemical_compoundchemistryEnvironmental ChemistrySample preparationFourier transform infrared spectroscopySpectroscopyAnalytica Chimica Acta
researchProduct

Mid- and near-infrared determination of metribuzin in agrochemicals

2008

Abstract Two infrared-based methodologies were developed for metribuzin determination in pesticide formulations after extraction with acetonitrile. Fourier transform mid infrared (MIR) procedure was based on peak area measurements between 1692 and 1670 cm −1 corrected with a baseline fixed at 1877 cm −1 . Fourier transform near infrared (NIR) determination was made by measuring the peak area between 6498 and 6332 cm −1 corrected using a two points baseline defined between 6570 and 6212 cm −1 . Repeatability, as relative standard deviation, of 5 independent measurements at mg g −1 concentration level was 0.3% and 0.03% for MIR and NIR, respectively, and limit of detection values of 9 and 17 …

Detection limitChromatographyInfraredChemistryNear-infrared spectroscopyExtraction (chemistry)Analytical chemistryRepeatabilitychemistry.chemical_compoundsymbols.namesakeFourier transformMetribuzinsymbolsAcetonitrileSpectroscopyVibrational Spectroscopy
researchProduct

Liquid Chromatography Quadrupole Time-of-Flight Mass Spectrometry Analysis of Carbosulfan, Carbofuran, 3-Hydroxycarbofuran, and Other Metabolites in …

2007

The potential of liquid chromatography quadrupole time-of-flight mass spectrometry (LC-QqTOF-MS) to identify and confirm carbosulfan and seven of its main metabolites (carbofuran, 3-hydroxycarbofuran, 3-ketocarbofuran, 3-hydroxy-7-phenol carbofuran, 3-keto-7-phenolcarbofuran, 7-phenolcarbofuran, dibutylamine) at trace levels from food is explored for the first time. The analytical method developed consists of pressurized liquid extraction (PLE) and LC-QqTOF-MS in positive ion mode, which attains unequivocal identification and quantification of the studied compounds in food, at levels well below of those of concern (0.05 mg/kg for the sum of carbosulfan, carbofuran, and 3-hydroxycarbofuran).…

Detection limitChromatographyMolecular StructureMetaboliteRepeatabilityButylaminesMass spectrometrySensitivity and SpecificityAnalytical ChemistryDibutylamineCarbofuranchemistry.chemical_compoundchemistrySpectrometry Mass Matrix-Assisted Laser Desorption-IonizationCarbosulfanCarbamatesQuantitative analysis (chemistry)CarbofuranFood AnalysisChromatography LiquidAnalytical Chemistry
researchProduct

An environmentally friendly multicommutated alternative to the reference method for anionic surfactant determination in water

2004

Abstract It has been developed a fully mechanized procedure for the spectrophotometric determination of anionic surfactants in water expressed in terms of SDS concentration. The reference method, based on the reaction of SDS with methylene blue (MB) followed by extraction in chloroform, was mechanized in order to reduce the consumption of organic solvents. The system was based on the multicommutation approach and provided a 35 times reduction of the waste production without sacrificing the figures of merit of the method in terms of sensitivity and repeatability, for a dynamic linear range from 0.2 to 1.7 mg l−1. Results obtained for washing water samples were comparable with those obtained …

Detection limitChromatographymedicine.diagnostic_testChemistryExtraction (chemistry)Analytical chemistryRepeatabilityAnalytical ChemistrySolventPulmonary surfactantLinear rangeSpectrophotometrymedicineSample preparationTalanta
researchProduct

Determination of n-alkanes, PAHs and hopanes in atmospheric aerosol: evaluation and comparison of thermal desorption GC-MS and solvent extraction GC-…

2019

Organic aerosol (OA) constitutes a large fraction of fine particulate matter (PM) in the urban air. However, the chemical nature and sources of OA are not well constrained. Quantitative analysis of OA is essential for understanding the sources and atmospheric evolution of fine PM, which requires accurate quantification of some organic compounds (e.g., markers). In this study, two analytical approaches, i.e., thermal desorption (TD) gas chromatography-mass spectrometry (GC-MS) and solvent extract (SE) GC-MS were evaluated for the determination of n-alkanes, polycyclic aromatic hydrocarbons (PAHs), and hopanes in ambient aerosol. For the SE approach, the recovery obtained is 89.3–101.5&…

Detection limitEnvironmental chemistryThermal desorptionEnvironmental scienceCoal combustion productsFraction (chemistry)Repeatability010501 environmental sciencesGas chromatography–mass spectrometryMass spectrometry01 natural sciences0105 earth and related environmental sciencesAerosol
researchProduct

Comparison of different methods for extraction of polycyclic aromatic hydrocarbons (PAHs) from Sicilian (Italy) coastal area sediments.

2012

This paper describes a work aimed at improving the conditions of an extraction method, coupling GC-MS determination, for the analysis without cleanup phase, of polycyclic aromatic hydrocarbons (PAHs) from sediment samples. The automatic Soxhlet extraction in warm mode (using Extraction System B-811 Standard, Buchi) has demonstrated advantages for automation, reduced extraction time, and lower solvent use than for conventional Soxhlet extraction. Under these conditions, the recoveries are very good as they resulted greater than 85 % and, in most of the cases, near 100 %. The repeatability is also satisfactory (relative standard deviation less than 15 %). The detection limits are also accepta…

Detection limitGeologic SedimentsExtraction (chemistry)SedimentGeneral MedicineRepeatabilityChemical FractionationManagement Monitoring Policy and LawPollutionGas Chromatography-Mass SpectrometrySettore CHIM/12 - Chimica Dell'Ambiente E Dei Beni CulturaliMatrix (chemical analysis)Dry weightEnvironmental chemistryEnvironmental scienceEcotoxicologySeawaterSettore CHIM/01 - Chimica AnaliticaPolycyclic Aromatic HydrocarbonsGas chromatography–mass spectrometryAutomatic extraction .CRM . PAHs . Sediments . GC-MSSicilyWater Pollutants ChemicalEnvironmental MonitoringGeneral Environmental Science
researchProduct

Introducing a new and rapid microextraction approach based on magnetic ionic liquids: Stir bar dispersive liquid microextraction

2017

With the aim of contributing to the development and improvement of microextraction techniques, a novel approach combining the principles and advantages of stir bar sorptive extraction (SBSE) and dispersive liquid-liquid microextraction (DLLME) is presented. This new approach, termed stir bar dispersive liquid microextraction (SBDLME), involves the addition of a magnetic ionic liquid (MIL) and a neodymium-core magnetic stir bar into the sample allowing the MIL coat the stir bar due to physical forces (i.e., magnetism). As long as the stirring rate is maintained at low speed, the MIL resists rotational (centrifugal) forces and remains on the stir bar surface in a manner closely resembling SBS…

Detection limitMagnetic ionic liquidChromatographyChemistryMagnetism010401 analytical chemistryExtraction (chemistry)Analytical chemistryThermal desorption02 engineering and technologyRepeatability021001 nanoscience & nanotechnology01 natural sciencesBiochemistry0104 chemical sciencesAnalytical Chemistrychemistry.chemical_compoundIonic liquidEnvironmental Chemistry0210 nano-technologySpectroscopyBar (unit)Analytica Chimica Acta
researchProduct