Search results for "Repeatability"

showing 10 items of 214 documents

Continuous monitoring of hydrogen and carbon dioxide at Mt Etna

2013

article i nfo This study assessed the use of an H2 fuel cell as an H2-selective sensor for volcano monitoring. The resolution, repeatability, and cross-sensitivity of the sensor were investigated and evaluated under known laboratory conditions. A tailor-made device was developed and used for continuously monitoring H2 and CO2 at Mt Etna throughout 2009 and 2010. The temporal variations of both parameters were strongly correlated with the evolution of the volcanic activity during the monitoring period. In particular, the CO2 flux exhibited long-term variations, while H2 exhibited pulses immediately before the explosive activity that occurred at Mt Etna during 2010.

geographygeography.geographical_feature_categoryHydrogenContinuous monitoringCo2 fluxchemistry.chemical_elementSoil CO2 fluxH2 monitoringH2 fuel cell Mt EtnaGeologyRepeatabilityAtmospheric sciencesSettore GEO/08 - Geochimica E VulcanologiaSoil co2 fluxchemistry.chemical_compoundVolcanochemistryGeochemistry and PetrologyCarbon dioxideFuel cellsSeismologyGeologyChemical Geology
researchProduct

The Test–Retest Repeatability of a Rhythm Coordination Test Procedure in 4- to 6-Year-Old Children : A Pilot Study

2020

Moving to music combines the ability of rhythm and coordination. In relation to the musical and motor development of children, sensorimotor synchronization requires the ability to perceive and perform a steady beat. The present pilot study aimed to investigate the test–retest repeatability of a rhythm coordination test procedure in order to pilot the procedure for children. Test–retest repeatability reflects the variation in measurements taken by the rhythm coordination test on the same participant under the same conditions. Ten children (mean age 5.5 years, standard deviation (SD) 0.6) participated in the tests. The test performance was evaluated in points from 0 to 8, separately at a slow…

lcsh:M1-5000medicine.medical_specialtykoordinaatio (motoriikka)lcsh:BF1-990sensomotorinen kehitysmusiikkiAudiologyRhythmSensorimotor integrationrytmitajuSynchronization (computer science)medicinesensorimotor integrationMotor skilllapsen kehityschild developmentlcsh:MusicTest proceduresmovement to musickehonhallintaRepeatabilityChild development3142 Public health care science environmental and occupational healthTest (assessment)3141 Health care sciencelcsh:Psychologybeat perceptionPsychologyperformance
researchProduct

Method for Reproducible Shipboard Segmented Flow Analysis Ammonium Measurement Using an In-House Reference Material for Quality Control

2021

Ammonium is a fundamental nutrient for phytoplankton growth in seawater and is a key component of the microbial loop. Ammonium measured in parallel with other nutrients is crucial in understanding the small temporal scale changes in oceanographic ecology. Despite the importance of measuring ammonium at sea, owing to its lability, there is no consensus on the best method. The lack of availability of certified reference materials for ammonium in seawater also makes it difficult to assess the accuracy and reproducibility of ammonium measurements. In this study we present a modified segmented flow analysis method using ortho-phthaldialdehyde (OPA) with fluorescence detection to measure ammonium…

lcsh:QH1-199.5Flow (psychology)NITROGEN ASSIMILATIONSoil scienceEnvironmental Sciences & EcologyCOLORIMETRIC DETERMINATIONOcean Engineeringlcsh:General. Including nature conservation geographical distributionAquatic SciencechemistryNUTRIENTSOceanography01 natural sciencesESTUARINE03 medical and health scienceschemistry.chemical_compoundNitrateOCEANnutrientsPHYTOPLANKTONPHOSPHATEAmmoniumMarine & Freshwater BiologyNitritequality controllcsh:Scienceseawater030304 developmental biologyWater Science and Technology0303 health sciencesReproducibilityGlobal and Planetary ChangeScience & TechnologySTABILITYSEAWATER010401 analytical chemistryRepeatability0104 chemical sciencesammoniumCertified reference materialschemistrylcsh:QSeawaterLife Sciences & BiomedicineEnvironmental Sciencesshipboard analysisNITRATEFrontiers in Marine Science
researchProduct

Personality predicts social dominance in female zebra finches, Taeniopygia guttata, in a feeding context.

2011

6 pages; International audience; Although personality has been defined as a suite of correlated behaviours, most studies of animal personality actually consider correlations between a few traits. We examined the repeatability and correlational structure of five potential personality traits (activity, neophobia, exploratory tendencies, risk-taking behaviour and obstinacy), in female zebra finches. In addition, we assessed to what extent personality influenced social dominance in a feeding context in this gregarious species. All personality traits were found to be highly repeatable within individuals. In addition, except for obstinacy, all of them were related to each other, thus defining a b…

media_common.quotation_subjectContext (language use)hierarchyPersonality psychologydominancefeeding successDevelopmental psychologybehavioural syndrome10127 Institute of Evolutionary Biology and Environmental Studies[ SDV.EE.IEO ] Life Sciences [q-bio]/Ecology environment/SymbiosisPersonalityBig Five personality traitsrepeatabilityZebra finchEcology Evolution Behavior and Systematicsmedia_common[ SDE.BE ] Environmental Sciences/Biodiversity and Ecologylife history productivityzebra finchAlternative five model of personalitySocial relationDominance (ethology)1105 Ecology Evolution Behavior and Systematicspersonality570 Life sciences; biology590 Animals (Zoology)Animal Science and Zoologyfalse discovery rate[SDE.BE]Environmental Sciences/Biodiversity and Ecology1103 Animal Science and ZoologyPsychologySocial psychologycompetition[SDV.EE.IEO]Life Sciences [q-bio]/Ecology environment/Symbiosis
researchProduct

Four color-measuring devices compared with a spectrophotometric reference system

2009

Abstract Objectives The objective of this study was to compare the L*C*h° color coordinates of dental color-measuring devices with those of a spectrophotometric reference system. Methods The International Commission on Illumination (CIE) L*C*h° color coordinates of ceramic samples, matching the colors of the VITA Linearguide, were recorded using four color-measuring devices (VITA Easyshade (A), VITA Easyshade compact (B), Degudent Shadepilot (C), X-Rite Shadevision (D)) and a spectrophotometric reference system under standardized test conditions. The intraclass correlation coefficients, regression lines with coefficients of determination, and mean deviations of the dental color-measuring de…

medicine.diagnostic_testProsthesis ColoringIntraclass correlationAnalytical chemistryColorReproducibility of ResultsRepeatabilityDental Prosthesis DesignSpectrophotometrySpectrophotometryLinear regressionLinear ModelsmedicineMeasuring instrumentHumansTooth DiscolorationColorimetryColorimetryGeneral DentistryColor coordinatesHueMathematicsJournal of Dentistry
researchProduct

Rationally designed haptens for highly sensitive monoclonal antibody-based immunoanalysis of fenhexamid.

2018

Immunochemical methods have been consolidated during the last few years as complementary analytical strategies for chemical contaminant and residue determination. However, generation of suitable immunoreagents for small organic molecules demands adequate hapten design. In this study, fenhexamid was considered as a model compound and novel haptens were designed and synthesized in order to evaluate the influence of the linker tethering site on antibody binding properties and immunoassay parameters. Haptens were conceived with the spacer arm at different positions, while the more antigenic aromatic moiety was kept free. The synthesis of these functionalized compounds was accomplished by total …

medicine.drug_classEnzyme-Linked Immunosorbent AssayTandem mass spectrometryQuechersMonoclonal antibody01 natural sciencesBiochemistryAnalytical ChemistryLimit of DetectionElectrochemistrymedicineEnvironmental ChemistrySpectroscopyDetection limitResidue (complex analysis)Chromatographymedicine.diagnostic_test010405 organic chemistryChemistry010401 analytical chemistryAntibodies MonoclonalRepeatabilityAmides0104 chemical sciencesFungicides IndustrialImmunoassayHaptenHaptensThe Analyst
researchProduct

Resonance frequency analysis-reliability in third generation instruments : Osstell mentor ®

2012

Few studies assess repeatability and reproducibility in registers of resonance frequency analysis (a value of dental implant stability). Objective: Few studies assess repeatability and reproducibility in resonance frequency analyses (implant stability evaluation). This study is aimed at assessing reliability (repeatabilty and reproducibility) in the Osstell Mentor® system using the intraclass correlation coefficient (ICC) as the statistical method. Study Design: ISQ measurements of RFA were carried out by means of the Osstell Mentor ® instrument in 58 implants in 19 patients. Six measurements were performed on each implant by means of two different Smart-Pegs (I and II). Three consecutive m…

medicine.medical_specialtyIntraclass correlationmedicine.medical_treatmentmedicineHumansPeriodontologyDental implantGeneral DentistryReliability (statistics)Dental ImplantsReproducibilitybusiness.industryReproducibility of ResultsRepeatability:CIENCIAS MÉDICAS [UNESCO]Confidence intervalSurgeryDental ImplantationResonance frequency analysisOtorhinolaryngologyUNESCO::CIENCIAS MÉDICASResearch-ArticleSurgeryImplantbusinessBiomedical engineering
researchProduct

Reliability of iCare ic100 Rebound Tonometry and Agreement With Goldmann Applanation Tonometry in Healthy and Post-myopic LASIK Patients.

2021

Rebound tonometry offers excellent reliability for obtaining intraocular pressure (IOP) measurements in healthy and post-myopic laser-assisted in situ keratomileusis (LASIK) patients regardless of corneal parameters and axial length and regardless of the instillation of ocular topical anesthesia.The purpose of this study was to assess the reliability of rebound tonometry, its agreement with Goldmann applanation tonometry (GAT) and its concordance after topical anesthesia in a group of nonoperated healthy patients and a group of post-myopic LASIK patients.Fifty-four patients were included in this prospective observational, case-control study. Patients were divided into 2 groups: control (n=3…

medicine.medical_specialtyIntraocular pressuregenetic structuresIntraclass correlationManometrymedicine.medical_treatmentConcordanceKeratomileusis Laser In SituGlaucomaKeratomileusisCorneaTonometry OcularOphthalmologymedicineHumansIntraocular PressureReproducibilitybusiness.industryLASIKReproducibility of ResultsRepeatabilitymedicine.diseaseeye diseasesOphthalmologyCase-Control Studiessense organsbusinessJournal of glaucoma
researchProduct

Validity of automated refraction after segmented refractive multifocal intraocular lens implantation

2017

Aim To evaluate the clinical utility of automated refraction (AR) and keratometry (KR) compared with subjective or manifest refraction (MR) after cataract or refractive lens exchange surgery with implantation of Lentis Mplus X (Oculentis GmbH) refractive multifocal intraocular lens (IOL). Methods Eighty-six eyes implanted with the Lentis Mplus X multifocal IOL were included. MR was performed in all patients followed by three consecutive AR measurements using the Topcon KR-8000 autorefractor. Assessment of repeatability of consecutive AR before and after dilation with phenylephrine 10%, and comparison of the AR and KR with MR using vector analysis were performed at 3mo follow-up. Results Ana…

medicine.medical_specialtygenetic structuresSpherical equivalentMean differencelaw.invention03 medical and health sciences0302 clinical medicinelcsh:OphthalmologyClinical ResearchlawOphthalmologymedicineDioptreKeratometerbusiness.industry1733autorefractionvector analysisRepeatabilityMultifocal intraocular lensRefractioneye diseasesOphthalmologylcsh:RE1-994Autorefractor030221 ophthalmology & optometrymultifocal intraocular lensessense organsbusinessagreement030217 neurology & neurosurgeryInternational Journal of Ophthalmology
researchProduct

Validity and repeatability of the Pediatric Allergy Questionnaire for Athletes (AQUAped) for the screening of atopy.

2020

BACKGROUND High atopy prevalence has been reported in athletes. Having an age-specific questionnaire for predicting atopy is important for an optimal management of young athletes. The study objectives were as follows: (i) developing a scoring system for the Pediatric Allergy Questionnaire for Athletes (AQUAped); (ii) identifying the optimal age target within the range 7-14 years; (iii) assessing AQUAped validity and repeatability in the identified target population. METHODS A total of 133 young athletes (age 7-14 years) were recruited. Following a screening visit, the participants filled AQUAped at baseline (T0) and after 7 days (T1), concomitantly undergoing skin prick testing. Using atopy…

medicine.medical_specialtyvalidityAdolescentImmunologyatopymedicine.disease_causeAtopy03 medical and health sciences0302 clinical medicineSettore MED/38 - Pediatria Generale E SpecialisticachildrenInternal medicineSurveys and QuestionnairesmedicineHypersensitivityImmunology and AllergyHumansMass Screening030212 general & internal medicinerepeatabilityChildSkin Testsyoung athletesReceiver operating characteristicbiologyAthletesbusiness.industryscreeningAQUApedInfant NewbornAeroallergenGold standard (test)Repeatabilitybiology.organism_classificationmedicine.diseaseOptimal management030228 respiratory systemAthletesPediatrics Perinatology and Child HealthPediatric allergybusinessPediatric allergy and immunology : official publication of the European Society of Pediatric Allergy and ImmunologyREFERENCES
researchProduct