Search results for "Replacement"
showing 10 items of 561 documents
Bone mineral density in relation to anthropometric properties, physical activity and smoking in 75-year-old men and women
1993
Bone mineral content (BMC, gem−2) and density (BMD, gem−3) were studied in 75-year-old men and women in relation to anthropometric and certain life-style factors. This study covered all the men and women born in 1914 who were residents in the city of Jyvaskyla in 1989 (N=388). A hundred and three men and 188 women participated in bone measurements performed at the calcaneus using a 125I-photon absorption method. BMC was on average 36% and BMD 17% higher in the men than in the women. BMC and BMD associated with body mass in both sexes, and with body fat and use of estrogen in the women. There was a negative correlation between the BMD values and the number of cigarettes smoked over the entir…
Continuous Femoral Catheter for Postoperative Analgesia After Total Knee Arthroplasty
2020
Introduction Postoperative pain management in the total knee replacement (TKR) represent a fundamental step for a positive outcome, allowing rapid mobilization, already on the first day. Further, continuous peripheral nerve block techniques have been reported to allow effective and safe control of acute postoperative pain, ensuring the implementation and completion of an accurate and intensive joint rehabilitation program. Aim The aim of this study was to assess early mobility and compliance of patients that underwent TKR surgery using the femoral block. Methods For the study, all patients that underwent TKR from 2015 to 2018 with ASA score between II-III was evaluated. Patients underwent v…
Quantification of Bone Density of the Proximal Femur After Hip Resurfacing Arthroplasty—Comparison of Different DXA Acquisition Modes
2010
Total hip arthroplasty (THA) is a traditional operative procedure in the treatment of osteoarthritis. The hip resurfacing arthroplasty (HRA) provides an alternative to the THA for young active patients. HRA is a bone-preserving procedure eliminating the problem of proximal femoral stress shielding and osteolysis associated to THA. Unfortunately, there is no standardized methodology to monitor the quality of bone after HRA. In this study, areal bone mineral density (BMD) in the operated hip (10 regions of interests [ROIs] of 34 volunteered HRA patients) was measured using Lunar Prodigy dual-energy X-ray absorptiometry, and the agreement of a standard (dual femur) and an orthopedic (orthopedi…
Influence of Different DXA Acquisition Modes on Monitoring the Changes in Bone Mineral Density After Hip Resurfacing Arthroplasty
2011
Dual-energy X-ray absorptiometry (DXA) is a technique enabling the measurement of bone mineral density (BMD) around prostheses after hip resurfacing arthroplasty (HRA). In this study, we evaluated the consistency of different DXA acquisition modes with 33 patients who had undergone HRA. Patients were scanned with DXA immediately after surgery and at 3-, 6-, and 12-mo time points. All the patients were scanned with dual femur and orthopedic hip acquisition modes and analyzed using 10-region ROI model. With both acquisition modes, a statistically significant decrease (p0.05, Wilcoxon's test) in BMD at 3mo was revealed in 3 ROIs, located to upper and lateral upper femur. Both acquisition modes…
Differences in gait characteristics between total hip, knee, and ankle arthroplasty patients: a six-month postoperative comparison.
2013
International audience; BACKGROUND: The recovery of gait ability is one of the primary goals for patients following total arthroplasty of lower-limb joints. The aim of this study was to objectively compare gait differences of patients after unilateral total hip arthroplasty (THA), total knee arthroplasty (TKA) and total ankle arthroplasty (TAA) with a group of healthy controls. METHODS: A total of 26 TAA, 26 TKA and 26 THA patients with a mean (+/- SD) age of 64 (+/- 9) years were evaluated six months after surgery and compared with 26 matched healthy controls. Subjects were asked to walk at self-selected normal and fast speeds on a validated pressure mat. The following spatiotemporal gait …
Secondary Osseous Integration of Cementless Unicompartmental Knee Arthroplasty After Internal Fixation of a Felix Type IIIB Fracture
2021
Case A 76-year-old man presented with periprosthetic tibial plateau fracture (TPF), with a completely loosened tibial component 3 weeks after cementless unicompartmental knee arthroplasty (UKA). Internal fixation by buttress plating was performed, and the tibial component was retained and left in situ primarily as a spacer. Revision was planned after fracture consolidation, but at 3 months, the patient was able to walk without support, without pain, and with full range of motion. At 1 year, he is free of complaints. The initial loosened tibial component reintegrated. Conclusion Internal fixation combined with preserving the loosened tibial component may be a treatment option for TPF involvi…
Do sex and pain characteristics influence the effectiveness of pain neuroscience education in people scheduled for total knee arthroplasty? Secondary…
2021
Abstract Objective This explorative study investigates the moderating effect of sex and baseline pain characteristics on the effectiveness of preoperative pain neuroscience education (PNE) plus knee joint mobilization versus biomedical education plus knee joint mobilization in patients who have knee osteoarthritis and are scheduled to undergo total knee arthroplasty (TKA). Methods After baseline assessment of self-reported questionnaires (pain intensity, disability, symptoms of central sensitization and pain cognitions) and quantitative sensory testing, 44 participants with knee osteoarthritis were randomized into the PNE plus knee joint mobilization or biomedical education plus knee joint …
Viscoelastic material models for more accurate polyethylene wear estimation
2018
Wear debris from ultra-high-molecular-weight polyethylene components used for joint replacement prostheses can cause significant clinical complications, and it is essential to be able to predict implant wear accurately in vitro to prevent unsafe implant designs continuing to clinical trials. The established method to predict wear is simulator testing, but the significant equipment costs, experimental time and equipment availability can be prohibitive. It is possible to predict implant wear using finite element methods, though those reported in the literature simplify the material behaviour of polyethylene and typically use linear or elastoplastic material models. Such models cannot represe…
2017
Joint replacement surgery is associated with significant morbidity and mortality following infection with either methicillin-resistant Staphylococcus aureus (MRSA) or Staphylococcus epidermidis. These organisms have strong biofilm-forming capability in deep wounds and on prosthetic surfaces, with 103 -104 microbes resulting in clinically significant infections. To inhibit biofilm formation, we developed 3D titanium structures using selective laser melting and then coated them with a silver nanolayer using atomic layer deposition. On bare titanium scaffolds, S. epidermidis growth was slow but on silver-coated implants there were significant further reductions in both bacterial recovery (p < …
Experiences with applications of macromolecular tools in supramolecular crystallography
2014
Supramolecular structures, with ever increasing size ranging from a few up to tens of nanometres, represent an intermediate stage between small molecules and biological macromolecules. Many crystal structures of these large supramolecular assemblies have been solved using dual space algorithms. However, supramolecular assemblies with a capsular shape present a particular challenge for crystallography, especially when they are chiral and composed of only light atoms. In this paper, we show that the application of “routine” macromolecular tools may be of great help in solving the crystal structures of supramolecular assemblies that are otherwise refractory to the routine methods of small mole…