Search results for "Reproducibility of result"

showing 10 items of 1840 documents

Effect of contact lenses on ocular biometric measurements based on swept-source optical coherence tomography

2019

ABSTRACT Purpose: To determine the reliability of swept- source optical coherence tomography in cases in which soft contact lenses cannot be removed when acquiring biometric measurements. Methods: Eight subjects were included and only one eye per participant was analyzed. Each eye was measured six times by swept-source optical coherence tomography with the IOLMaster 700 instrument (Carl Zeiss Meditec, Jena, Germany). Axial length, central corneal thickness, anterior chamber depth, lens thickness, and keratometric measurements were evaluated for the naked eye and while wearing soft contact lenses of three different powers (-1.5, -3.0, and +2.0 D). Results: There were statistically significan…

AdultBiometryMaterials sciencegenetic structuresContact LensesTomography optical coherenceStatistics Nonparametriclaw.invention03 medical and health sciences0302 clinical medicineOpticslcsh:OphthalmologyOptical coherence tomographyLens thicknessAnterior Eye SegmentReference ValueslawmedicineHumansContact lensesAnalysis of VarianceCross-Over Studiesmedicine.diagnostic_testbusiness.industryReproducibility of ResultsGeneral MedicineAxial lengtheye diseasesContact lensLens (optics)Axial Length EyeOphthalmologylcsh:RE1-994Reference values030221 ophthalmology & optometrysense organsTomographybusinessTomography Optical CoherenceArquivos Brasileiros de Oftalmologia
researchProduct

False positive rate of an arrayCGH platform for single-cell preimplantation genetic screening and subsequent clinical application on day-3

2013

In this work, false positive rate of an arrayCGH platform for its use in day-3 single-blastomere analysis was calculated. For this purpose, 38 embryos diagnosed as abnormal on day-3 by FISH were re-biopsied on day-4. Single-cell day-4 arrayCGH diagnosis was then performed. A successful amplification was obtained in 97.4 % (37/38) of the day-4 cells analysed by arrayCGH. Day-3 FISH and day-4 arrayCGH diagnosis were concordant in 35/37 cases. The two discordant embryos were spread and all the cells from each embryo were re-analysed by FISH on day 5. The same error rate (2.7 %) for day-3 FISH and day-4 arrayCGH was obtained when comparing day-5 FISH re-analysis. After this pre-clinical phase, …

AdultBlastomeresmedicine.medical_specialtyTime FactorsPregnancy RateBiopsyConcordanceClinical pregnancyBiologySensitivity and SpecificityMiscarriagePregnancyarrayCGHDay-5 FISH re-analysisGeneticsmedicineChromosomes HumanHumansFalse Positive ReactionsEmbryo ImplantationGenetic TestingProspective StudiesIn Situ Hybridization FluorescenceGenetics (clinical)CryopreservationGynecologyComparative Genomic HybridizationReproducibility of ResultsObstetrics and GynecologyGeneral MedicineAneuploidyEmbryo Transfermedicine.diseaseBlastocystReproductive MedicineBlastomere biopsyBlastomere biopsyFish <Actinopterygii>Day-3 PGSFemaleFalse positive rateDevelopmental Biology
researchProduct

Improved usability of the minimal model of insulin sensitivity based on an automated approach and genetic algorithms for parameter estimation.

2006

Minimal model analysis of glucose and insulin data from an IVGTT (intravenous glucose tolerance test) is widely used to estimate insulin sensitivity; however, the use of the model often requires intervention by a trained operator and some problems can occur in the estimation of model parameters. In the present study, a new method for minimal model analysis, termed GAMMOD, was developed based on genetic algorithms for the estimation of model parameters. Such an algorithm does not require the fixing of initial values for the parameters (that may lead to unreliable estimates). Our method also implements an automated weighting scheme not requiring manual intervention of the operator, thus impro…

AdultBlood GlucoseComputer scienceEstimation theorybusiness.industryDecision treeEvolutionary algorithmReproducibility of ResultsContext (language use)UsabilityGeneral MedicineGlucose Tolerance TestModels BiologicalWeightingMinimal modelDiabetes GestationalPregnancyGenetic algorithmHumansInsulinFemaleInsulin ResistancebusinessAlgorithmAlgorithmsClinical science (London, England : 1979)
researchProduct

Glycaemic variability and inflammation in subjects with metabolic syndrome.

2008

Subjects who develop diabetes have an increased cardiovascular risk even before the appearance of diabetes. The aim of this study was to investigate the glycaemic variability measured by continuous glucose monitoring (CGM CV%) in nondiabetic subjects with metabolic syndrome (MS) and to explore if glycaemic variability was associated with circulating levels of interleukin-6 (IL-6), a proinflammatory cytokine, or with an anti-inflammatory factor like adiponectin. Three groups of obese subjects with (MS+: 6m, 8f; BMI 33.1 ± 1.4 mean ± SEM) or without metabolic syndrome (MS−: 2m, 4f; BMI 29.2 ± 2.2) and with MS associated with type 2 diabetes (MS/T2D: 3m, 5f; BMI 32.9 ± 1.4) were investigated. …

AdultBlood GlucoseMalemedicine.medical_specialtyWaistendocrine system diseasesEndocrinology Diabetes and Metabolismmedicine.medical_treatmentMonitoring AmbulatoryBlood sugarType 2 diabetesBody Mass IndexEndocrinologyInternal medicineDiabetes mellitusInternal MedicinemedicineHumansObesityMetabolic SyndromeAdiponectinbusiness.industryInsulinReproducibility of Resultsnutritional and metabolic diseasesGeneral Medicinemedicine.diseaseObesityEndocrinologyFemaleWaist CircumferenceMetabolic syndromeVariabilità glicemica flogosi sindrome metabolicabusiness
researchProduct

United States and European Multicenter Prospective Study for the Analytical Performance and Clinical Validation of a Novel Sensitive Fully Automated …

2016

Abstract BACKGROUND The objective of this study is the validation and proof of clinical relevance of a novel electrochemiluminescence immunoassay (ECLIA) for the determination of serum calcitonin (CT) in patients with medullary thyroid carcinoma (MTC) and in different diseases of the thyroid and of calcium homeostasis. METHODS This was a multicenter prospective study on basal serum CT concentrations performed in 9 US and European referral institutions. In addition, stimulated CT concentrations were measured in 50 healthy volunteers after intravenous calcium administration (2.5 mg/kg bodyweight). RESULTS In total, 1929 patients and healthy controls were included. Limits of blank, detection, …

AdultCalcitoninMalemedicine.medical_specialtyPercentileClinical Biochemistry030209 endocrinology & metabolismGastroenterologySensitivity and SpecificityThyroid carcinoma03 medical and health sciences0302 clinical medicineInternal medicinemedicineHumansClinical significanceProspective StudiesProspective cohort studyCalcium metabolismAutomation LaboratoryImmunoassaymedicine.diagnostic_testbusiness.industryBiochemistry (medical)ThyroidReproducibility of ResultsReference StandardsUnited StatesEuropeEndocrinologymedicine.anatomical_structureCalcitonin030220 oncology & carcinogenesisImmunoassayCalciumFemalebusinessClinical chemistry
researchProduct

A randomized trial comparing conventional cytology to liquid-based cytology and computer assistance.

2012

Liquid-based cytology (LBC) has replaced conventional cytology (CC) for cervical cancer screening in some countries. However, it remains unclear whether LBC is superior to CC. A randomized controlled trial was conducted between August 2007 and March 2009 in Germany to compare LBC, alone and in combination with computer-assisted imaging technology (CAS), to CC in the detection of histologically confirmed cervical intraepithelial neoplasia (CIN). The main outcome measures were detection rates, relative sensitivities, positive predictive values (PPVs) and relative PPVs comparing LBC without and with CAS to CC. Primary histological outcome was CIN2 or higher. Included were 20,627 women particip…

AdultCancer Researchmedicine.medical_specialtyCytodiagnosisUterine Cervical NeoplasmsCervical intraepithelial neoplasiaGastroenterologySensitivity and Specificitylaw.inventionYoung AdultRandomized controlled triallawConventional cytologyCytologyInternal medicineMedicineHumansEarly Detection of CancerAgedGynecologyColposcopymedicine.diagnostic_testbusiness.industryReproducibility of ResultsMiddle Agedmedicine.diseaseConfidence intervalClinical trialOncologyLiquid-based cytologyFemalebusinessInternational journal of cancer
researchProduct

Axillary Nodal Burden in Breast Cancer Patients With Pre-operative Fine Needle Aspiration-proven Positive Lymph Nodes Compared to Those With Positive…

2019

BACKGROUND/AIM: Recent years have seen a considerable shift to a more conservative management of the axilla in patients with positive axillary sentinel lymph nodes. The aim of this study was to determine whether some breast cancer patients with a preoperative ultrasound-guided needle aspiration biopsy proven positive node could potentially be spared an axillary lymph node dissection according to the ACOSOG Z0011 trial criteria. PATIENTS AND METHODS: A retrospective review was performed involving 623 breast cancer patients who underwent axillary lymph node dissection after either ultrasound-guided needle aspiration biopsy proven positive node or sentinel lymph node biopsy. RESULTS: Patients …

AdultCancer Researchmedicine.medical_specialtyaxillary nodal burdenCytodiagnosisSentinel lymph nodeBiopsy Fine-NeedleBreast NeoplasmsSensitivity and SpecificityGeneral Biochemistry Genetics and Molecular Biology03 medical and health sciences0302 clinical medicineBreast cancerBreast cancerBiopsyPreoperative CareMedicineHumansBreastsentinel lymph node biopsyEndoscopic Ultrasound-Guided Fine Needle AspirationAgedRetrospective StudiesPharmacologyAged 80 and overmedicine.diagnostic_testbusiness.industryAxillary Lymph Node DissectionReproducibility of ResultsMiddle Agedmedicine.diseaseAxillaFine-needle aspirationmedicine.anatomical_structure030220 oncology & carcinogenesisLymphatic MetastasisAxillaFemaleRadiologyLymphLymph NodesbusinessNODALResearch Article
researchProduct

Reproducibility of imaging human knee cartilage by delayed gadolinium-enhanced MRI of cartilage (dGEMRIC) at 1.5 Tesla

2009

Summary Objective The purpose of this study was to investigate the day-to-day reproducibility of the delayed gadolinium-enhanced MRI of cartilage (dGEMRIC) measurement at different knee joint surfaces in healthy subjects at 1.5 Tesla (T). Methods The dGEMRIC experiment was repeated for 10 asymptomatic volunteers three times with an average interval of 5 days between scans. The measurement was performed from a single sagittal slice through the center of the lateral femoral condyle and from the center of the patella in the axial plane. Cartilage was manually segmented into superficial, deep and full-thickness regions of interests (ROIs) at different topographical locations of the femur, tibia…

AdultCartilage ArticularGadolinium DTPAMalemusculoskeletal diseasesdGEMRICmedicine.medical_specialtyIntraclass correlationBiomedical EngineeringContrast MediaKnee JointSensitivity and Specificity030218 nuclear medicine & medical imaging03 medical and health sciences0302 clinical medicineRheumatologymedicineHumansFemurOrthopedics and Sports MedicineTibiaRadionuclide Imaging030222 orthopedicsReproducibilitybusiness.industryCartilageReproducibility of ResultsMiddle AgedImage Enhancementmusculoskeletal systemMagnetic Resonance ImagingReproducibilityKnee jointSagittal planeCartilagemedicine.anatomical_structureProteoglycanFemalePatellaRadiologybusinessNuclear medicineOsteoarthritis and Cartilage
researchProduct

Assessment of normal patellar cartilage volume and thickness using MRI: an analysis of currently available pulse sequences.

1996

Objective. The objective of this study was to analyse the potential of magnetic resonance imaging for valid determination of patellar cartilage thickness, comparing currently available pulse sequences. Design. In six patients and one cadaver the cartilage was repetitively imaged employing three spin-echo and six three-dimensional gradient-echo sequences. In the cadaveric specimen the total volume and the regional distribution of cartilage thickness were assessed and compared with the values obtained from anatomical sections by image analysis. Results and conclusions. The FLASH and fat-suppressed FLASH sequences allowed the most accurate determination of the cartilage volume and thickness. F…

AdultCartilage ArticularMaleCadaverReference ValuesmedicineCadaverSynovial fluidHumansRadiology Nuclear Medicine and imagingReproducibilitymedicine.diagnostic_testbusiness.industryCartilageReproducibility of ResultsPulse sequenceMagnetic resonance imagingAnatomyPatellaMiddle AgedMagnetic Resonance Imagingmedicine.anatomical_structurePatellabusinessCadaveric spasmBiomedical engineeringSkeletal radiology
researchProduct

Magnetic resonance chondro-crassometry (MR CCM): a method for accurate determination of articular cartilage thickness?

1996

A method for the assessment of articular cartilage thickness based on MRI is presented and its accuracy and reproducibility tested. Six specimens of human patellae were imaged, using a fat-suppressed FLASH 3D sequence, and sectioned with a high-precision band saw. The regional distribution of articular cartilage thickness was determined from the MR images and from the anatomical sections (intervals of 0.5 mm). With image analysis 50-90% of the image points were found to lie within exactly the same thickness interval in corresponding patterns, and less than 17% deviated more than 0.5 mm. More than 85% of all pixels were reproducible with MRI after new positioning of the joint. No influence o…

AdultCartilage ArticularMaleMaterials scienceArticular cartilageNuclear magnetic resonanceReference ValuesmedicineImage Processing Computer-AssistedHumansRadiology Nuclear Medicine and imagingAgedAged 80 and overReproducibilityMeasurement methodmedicine.diagnostic_testAnthropometryCartilageReproducibility of ResultsMagnetic resonance imagingCartilage thicknessMiddle AgedMagnetic Resonance Imagingmedicine.anatomical_structureReference valuesFemaleMr imagesSoftwareMagnetic resonance in medicine
researchProduct