Search results for "Reproducibility"
showing 10 items of 1976 documents
Psychometric characteristics in normal and social phobic samples for a Spanish version of the Rosenberg Self-Esteem Scale.
2000
The present paper had three purposes: (a) presenting normative data for the Rosenberg Self-esteem Scale in a Spanish sample, (b) studying whether there are significant sex or age differences in self-esteem, and (c) studying whether there are significant differences between a Control group with no psychological diagnosis and a group of social phobics. Of the total sample of 266 persons, 214 belonged to the Control group and 52 to the Social Phobic group. Item-total score correlations and alpha reliabilities supported the internal consistency of the scale. There were statistically significant differences between the Control and Social Phobic groups, but not by sex or age.
Spanish version of the Screen for Cognitive Impairment in Psychiatry (SCIP-S): psychometric properties of a brief scale for cognitive evaluation in s…
2007
The Screen for Cognitive Impairment in Psychiatry (SCIP) is a brief scale designed for detecting cognitive deficits in several psychotic and affective disorders. This study examined the psychometric properties of the Spanish version of the SCIP in a sample of outpatients suffering schizophrenia-spectrum disorders.Psychometric properties were evaluated in a sample of 126 stable patients with schizophrenia. Men and women 18 to 55 years of age were recruited from consecutive admissions to 40 psychiatric outpatient clinics in Spain and asked to complete a series of cognitive measures at baseline, as well as three versions of the SCIP separated by one week intervals. A matched sample of 39 healt…
Reliability and validity of the German version of the European Addiction Severity Index (EuropASI).
2001
This study provides data on the psychometric characteristics of the German version of the European Addiction Severity Index (EuropASI). The ASI is a frequently used clinical and research instrument that measures problem severity among people with substance dependence.The German ASI was used in a sample of 112 consecutively admitted male psychiatric inpatients seeking treatment for severe alcohol problems. The conceptual structure of the German ASI subscales was investigated by analyzing the intercorrelations of the severity ratings and composite scores. Internal consistency, interrater reliability and concurrent validity in terms of correlations with other assessment instruments were evalua…
Cross cultural adaptation of the Injection Drug User Quality Of Life Scale (IDUQOL) in Spanish drug dependent population, with or without injectable …
2007
Abstract The Injection Drug User Quality of life Scale (IDUQOL) measures the unique and individual circumstances that determine the quality of life of injection drug users. This paper reports the psychometric properties of the Spanish version, for drug dependent persons with or without injectable consumption using a revised instrument: Drug user Quality of Life Scale-Spanish (DUQOL-Spanish). We studied 169 outpatients in 9 Spanish drug treatment centers. Factor analysis, internal consistency, test–retest reliability and criterion-related validity were assessed. The results show the essential unidimensionality of the scale, which supports the use of a total score. Both internal consistency (…
Reliability and validity of the Finnish version of the Lower Extremity Functional Scale (LEFS)
2017
The present study aimed to assess the psychometric properties of the Finnish version of the Lower Extremity Functional Scale (LEFS) among foot and ankle patients.The LEFS was translated and cross-culturally adapted to Finnish. We assessed the test-retest reliability, internal consistency, floor-ceiling effect, construct validity and criterion validity in patients who underwent surgery due to musculoskeletal pathology of the foot and ankle (N = 166).The test-retest reliability was high (ICC = 0.93, 95% CI: 0.91-0.95). The standard error of measurement was 4.1 points. The Finnish LEFS showed high internal consistency (Cronbach's α = 0.96). A slight ceiling effect occurred as 17% achieved the …
Evaluation of the Arthritis Impact Measurement Scales (AIMS2) in Finnish patients with rheumatoid arthritis
2003
Objective: To evaluate the validity and reliability of the Finnish version of the Arthritis Impact Measurement Scales (AIMS2) in Finnish patients with rheumatoid arthritis (RA).Methods: The reliability of the Finnish AIMS2 (Finn‐AIMS2) questionnaire was assessed by test–retest procedure and internal consistency of health‐status scales. Construct validity was assessed by factor analysis, and convergent validity by correlation coefficients, with several disease activity and functional status variables.Results: Internal consistency was 0.79–0.89 and test–retest reliability 0.72–0.97. Factor analysis identified three factors: physical, psychosocial, and pain. There were strong correlations betw…
Spanish cross-cultural adaptation and validation of the Australian Pelvic Floor Questionnaire in running women
2022
AbstractPelvic floor dysfunctions are a wide range of disorders in the gynaecological, lower urinary and gastrointestinal tracts that affect the structure and/or function of the pelvic organs. The objective of this study was to carry out a cross-cultural adaptation and a psychometric analysis of the Spanish version of the Australian Pelvic Floor Questionnaire. Observational study divided into two main phases: (1) translation and cross-cultural adaptation and (2) psychometric tests. Women runners from all over the Spanish territory, from different federations, clubs and levels were recruited. Participants: 424 female runners, native Spanish, over 18 years of age and who had been practicing r…
Enhancement pattern of small hepatocellular carcinoma (HCC) at contrast-enhanced US (CEUS), MDCT, and MRI: intermodality agreement and comparison of …
2012
OBJECTIVE:To evaluate agreement between contrast-enhanced ultrasound (CEUS), multi-detector row computed tomography (MDCT) and magnetic resonance imaging (MRI) for the assessment of typical and atypical enhancement patterns of small hepatocellular carcinoma (HCC); and to compare diagnostic sensitivity of 2005 and 2010 American Association for the Study of Liver Diseases (AASLD) guidelines. MATERIALS AND METHODS: Between January 2008 and December 2009, we included cirrhotic patients with newly diagnosed 10-20 mm HCC imaged at two contrast-enhanced imaging techniques among CEUS, MDCT, and MRI. Dynamic studies were reviewed by two radiologists to assess enhancement pattern. Percentage of cases…
Task and Ego Orientation in Sport Questionnaire (TEOSQ): Psychometric properties in its digital version
2022
The Task and Ego Orientation in Sport Questionnaire’s (TEOSQ’s) psychometric properties have been explored in previous studies but never in its digital version, which facilitates data collection. The objective of this study was to analyze the psychometric properties of the online TEOSQ by MenPas 1.0. The sample was composed of 2320 users (58.4% women; 41.6% men), between 18 and 65 years old (M = 25.27, SD = 7.39). The methods used were Confirmatory Factor Analysis (CFA) and invariance analysis from the original 13-item model. The CFA was corrected for all samples (CFI = 0.92–0.94, TLI = 0.93–0.95, RMSEA = 0.07, SRMR = 0.06; df = 64; Bollen-Stine Bootstrap p = 0.02–0.07): general sample (χ2 …
Development of a novel methodology for determination of dialkyl phosphates in human urine using liquid chromatography-tandem mass spectrometry
2019
Abstract In this study a fast and sensitive method was developed for the quantitative determination of six dialkyl phosphates (DAPs) in human urine using liquid chromatography-tandem mass spectrometry (LC-MS/MS). The proposed methodology was based on liquid-liquid extraction (LLE) with diethyl ether and ethyl acetate using MgSO4 and NaCl, followed by liquid chromatography and mass spectrometry detection in the selected reaction mode (SRM) with negative electrospray ionization (ESI-). Detection settings were optimized by design of experiments (DoE). Dibutyl phosphate (DBP) was used as internal standard. Several criteria established in the SANTE/11813/2017 guidance document for pesticide resi…