Search results for "Reproducibility"

showing 10 items of 1976 documents

Mikrostruktur der Lunge: Untersuchung mittels Diffusionsmessung von hochpolarisiertem 3Helium

2006

Imaging methods to study the lung are traditionally based on x-ray or on radioactive contrast agents. Conventional magnetic resonance imaging (MRI) has only limited applications for lung imaging because of the low tissue density of protons concentration of hydrogen atoms, which are usually the basis for the imaging. The introduction of hyperpolarized noble gases as a contrast agent in MRI has opened new possibilities for lung diagnosis. The present paper describes this new technique. Diffusion-weighted MRI for assessment of the lung microstructure is presented here as an example of the new possibilities of functional imaging. Studies to determine the sensitivity of the diffusion measurement…

ReproducibilityMaterials scienceRadiological and Ultrasound Technologymedicine.diagnostic_testBiophysicsMagnetic resonance imagingTissue densityFunctional imagingNuclear magnetic resonanceHealthy volunteersLung imagingmedicineRadiology Nuclear Medicine and imagingDiffusion MRIZeitschrift für Medizinische Physik
researchProduct

Duplexsonographie der normalen Pfortader

2008

In 50 normal subjects flow velocity and direction on the portal vein was measured by ultrasonic duplex system. The measurements revealed at a mean diameter of 9.7 mm, a mean flow velocity of 15.2 +/- 2.6 cm/s, corresponding to a volume flow of 693 +/- 235 ml/min. Postprandially this increased to 880 +/- 269 ml/min. Inter-observer and day to day measurements demonstrated good reproducibility. Thus, this simple non-invasive method is well suited for quantitative assessment of the portal vein system in portal hypertension, thrombosis or after shunt operations.

ReproducibilityMaterials sciencebusiness.industryPortal veinGeneral Medicinemedicine.diseaseThrombosisFlow velocitymedicineDuplex sonographyQuantitative assessmentPortal hypertensionNuclear medicinebusinessShunt (electrical)DMW - Deutsche Medizinische Wochenschrift
researchProduct

Reproducibility and accuracy in the morphometric and mechanical quantification of trabecular bone from 3Tesla magnetic resonance images

2014

Abstract Objective We used an animal model to analyze the reproducibility and accuracy of certain biomarkers of bone image quality in comparison to a gold standard of computed microtomography (μCT). Materials and methods We used magnetic resonance (MR) imaging and μCT to study the metaphyses of 5 sheep tibiae. The MR images (3 T) were acquired with a T1-weighted gradient echo sequence and an isotropic spatial resolution of 180 μm. The μCT images were acquired using a scanner with a spatial resolution of 7.5 μm isotropic voxels. In the preparation of the images, we applied equalization, interpolation, and thresholding algorithms. In the quantitative analysis, we calculated the percentage of …

ReproducibilityMaterials sciencemedicine.diagnostic_testImage qualitybusiness.industryMagnetic resonance imagingGold standard (test)computer.software_genreThresholdingFractal dimensionVoxelmedicineGeneral Earth and Planetary SciencesNuclear medicinebusinesscomputerImage resolutionGeneral Environmental ScienceBiomedical engineeringRadiología (English Edition)
researchProduct

Application unit for the administration of contrast gases for pulmonary magnetic resonance imaging: optimization of ventilation distribution for3He-M…

2014

Purpose MRI of lung airspaces using gases with MR-active nuclei (3He, 129Xe, and 19F) is an important area of research in pulmonary imaging. The volume-controlled administration of gas mixtures is important for obtaining quantitative information from MR images. State-of-the-art gas administration using plastic bags (PBs) does not allow for a precise determination of both the volume and timing of a 3He bolus. Methods A novel application unit (AU) was built according to the requirements of the German medical devices law. Integrated spirometers enable the monitoring of the inhaled gas flow. The device is particularly suited for hyperpolarized (HP) gases (e.g., storage and administration with m…

ReproducibilityMaterials sciencemedicine.diagnostic_testMagnetic resonance imaginglaw.inventionPulmonary imagingVolume (thermodynamics)lawAnesthesiaHealthy volunteersVentilation (architecture)medicineRadiology Nuclear Medicine and imagingHyperpolarization (physics)Mr imagesBiomedical engineeringMagnetic Resonance in Medicine
researchProduct

Water Dynamics in Neural Tissue

2013

Water dynamics in post-mortem two-years old bovine cerebral right hemisphere has been investigated through Elastic and Quasi-elastic Neutron Scattering. Experimental parameters such as stability in time of the proton dynamics, data reproducibility and changes in the tissues dynamics upon the conservation protocol, cryogenic towards formalin addition, have been carefully investigated. Results are extremely encouraging and comparisons to magnetic resonance imaging findings are discussed.

ReproducibilityMaterials sciencemedicine.diagnostic_testProtonneutron scatteringDynamics (mechanics)proton dynamicsGeneral Physics and AstronomyMagnetic resonance imagingNeutron scatteringNuclear magnetic resonanceWater dynamicsmedicineRight hemispherediffusion magnetic resonance imagingJournal of the Physical Society of Japan
researchProduct

Determination of the energetic value of fruit and milk-based beverages through partial-least-squares attenuated total reflectance-Fourier transform i…

2005

Abstract The estimation of important nutritional parameters, such as carbohydrates content and energetic value (calories) in commercially available fruit juice and flavour milk shakes has been made by attenuated total reflectance-Fourier transform infrared spectroscopy (ATR-FTIR) using a partial-least-square (PLS) calibration approach. A highly heterogeneous population of 65 samples obtained from the Spanish market, covering fruit juices, flavour milk shakes and milk-added fruit juices was used. The spectral range and the size of the calibration set for building the PLS model have been evaluated. Considering a calibration set comprised of 27 samples, selected via hierarchical cluster analys…

ReproducibilityMean squared errorChemistryFlavourAnalytical chemistryBiochemistryFourier transform spectroscopyStandard deviationAnalytical ChemistryAttenuated total reflectionPartial least squares regressionCalibrationEnvironmental ChemistrySpectroscopyAnalytica Chimica Acta
researchProduct

<title>Measurement methods of laser beam parameters</title>

2007

A wide range of measurements have been used during time in order to define the characteristics of laser beam, therefore it is useful to analyze and re-establish the role of each type of measurement. The scope of these measurements is to increase the precision and reproducibility with which beams propagate, interact and can be focused on a target (part) in an industrial process.

ReproducibilityMeasurement methodChemistrybusiness.industryProcess (computing)Laserlaw.inventionOpticslawRange (statistics)Laser beam qualitybusinessBeam (structure)Laser beamsSPIE Proceedings
researchProduct

Semiautomatic detection of myocardial contours in order to investigate normal values of the left ventricular trabeculated mass using MRI

2015

Purpose To propose, assess, and validate a semiautomatic method allowing rapid and reproducible measurement of trabeculated and compacted left ventricular (LV) masses from cardiac magnetic resonance imaging (MRI). Materials and Methods We developed a method to automatically detect noncompacted, endocardial, and epicardial contours. Papillary muscles were segmented using semiautomatic thresholding and were included in the compacted mass. Blood was removed from trabeculae using the same threshold tool. Trabeculated, compacted masses and ratio of noncompacted to compacted (NC:C) masses were computed. Preclinical validation was performed on four transgenic mice with hypertrabeculation of the LV…

ReproducibilityNoncompaction cardiomyopathymedicine.diagnostic_testbusiness.industryMean ageSteady-state free precession imagingNormal values030204 cardiovascular system & hematologymedicine.disease030218 nuclear medicine & medical imaging03 medical and health sciences0302 clinical medicineCine imagingAge groupsCardiac magnetic resonance imagingmedicineRadiology Nuclear Medicine and imagingbusinessNuclear medicineJournal of Magnetic Resonance Imaging
researchProduct

Limited Usefulness of Capture Procedure and Capture Percentage for Evaluating Reproducibility in Psychological Science

2018

In psychological science, there is an increasing concern regarding the reproducibility of scientific findings. For instance, Replication Project: Psychology (Open Science Collaboration, 2015) found that the proportion of successful replication in psychology was 41%. This proportion was calculated based on Cumming and Maillardet’s (2006) widely employed capture procedure (CPro) and capture percentage (CPer). Despite the popularity of CPro and CPer, we believe that using them may lead to an incorrect conclusion of (a) successful replication when the population effect sizes in the original and replicated studies are different; and (b) unsuccessful replication when the population effect sizes i…

ReproducibilityOpen sciencePsychological science05 social scienceslcsh:BF1-990050401 social sciences methodssimulationPopularitycapture percentage050105 experimental psychologycapture procedurelcsh:Psychology0504 sociologySample size determinationReplication (statistics)0501 psychology and cognitive sciencesPopulation effectPsychologyreproducibilityGeneral PsychologyCognitive psychologyeffect sizesFrontiers in Psychology
researchProduct

Response of GAFChromic® HD-V2 film dosimeter in 10-300 Gy dose range for radiation testing of electronic devices

2019

The study reported in this paper aimed to investigate the response of a GAFChromic? HD-V2 film dosimeter in the dose range between 10 and 300 Gy, normally used to perform irradiation tests on electronic devices with a 60Co gamma-ray irradiator. The well-defined linearity of response in terms of absorbance as a function of absorbed dose, easiness of handling and data analysis of irradiated dosimeters, reproducibility, stability, and insensitivity to visible light and most of the environmental parameters, make HD-V2 film a flexible, inexpensive and reliable dose measurement device. The study has shown a fogging effect of the dosimeter response since its value changes over time. Strategies and…

ReproducibilityRange (particle radiation)HD-V2 filmDosimeterMaterials scienceGafchromic dosimetryRadiation testingElectronic deviceNuclear Energy and EngineeringDoseGamma-ray irradiationAbsorbed doseCalibrationlcsh:QC770-798lcsh:Nuclear and particle physics. Atomic energy. RadioactivityIrradiationElectronicsSafety Risk Reliability and QualityBiomedical engineeringNuclear Technology and Radiation Protection
researchProduct