Search results for "Reproducibility"

showing 10 items of 1976 documents

Molecular Epidemiological Survey ofCitrobacter freundiiMisidentified asCronobacterspp. (Enterobacter sakazakii) andEnterobacter hormaecheiIsolated fr…

2011

A total of 75 powdered infant milk formula (PIF) samples collected from pharmacies and drugstores in Western Sicily, Italy, and representative of 12 different brands were analyzed in this study to evaluate their microbiological quality. According to the U.S. Food and Drug Administration protocol, 32 samples out of 75 were contaminated by enterobacteria. Commercial biochemical API(r) 20E-system identification method indicated that six PIF samples were presumptively contaminated by Cronobacter spp., but further characterization by alpha-glucosidase based polymerase chain reaction (PCR) assay identification strongly suggested that these strains did not belong to the genus Cronobacter. Phylogen…

Settore MED/07 - Microbiologia E Microbiologia ClinicaEnterobacterMicrobial Sensitivity TestsSettore MED/42 - Igiene Generale E ApplicataApplied Microbiology and BiotechnologyMicrobiologyMicrobiologylaw.inventionBacterial ProteinsCronobacter sakazakiiSpecies SpecificitylawRNA Ribosomal 16SDrug Resistance BacterialHumansFood microbiologyTypingCronobacterPhylogenyPolymerase chain reactionFood FormulatedbiologyInfantReproducibility of Resultsalpha-GlucosidasesEnterobacterFood Inspection16S ribosomal RNAbiology.organism_classificationInfant FormulaAnti-Bacterial AgentsBacterial Typing TechniquesCitrobacter freundiiCitrobacter freundii Enterobacter hormaechei powdered infant milk formulaCitrobacter freundiiRNA BacterialItalyFood MicrobiologyAnimal Science and ZoologyPowdersEnterobacter cloacaeFood ScienceFoodborne Pathogens and Disease
researchProduct

Reply: Time to Reconsider a Gold Standard of Lymph Flow Imaging: Importance of Reliability to Detect Abnormal Lymphodynamics in Lymphedema Screening …

2017

Reply to a Letter to Editor

Settore MED/19 - Chirurgia PlasticaLymph Node ExcisionReproducibility of ResultNeoplasmSurgeryLymphedemaHuman
researchProduct

Spanish validation of the Sexual Addiction Screening Test.

2018

Background and aims Sexual addiction is a pathological behavior characterized by a combination of excessive sexual desire and impaired ability to control it. Its incidence ranges between 1.2% and 32.2%, although this number may vary depending on the screening tool used. This wide variability is largely due to the use of non-validated instruments (e.g., structural validity relying on exploratory analyses, instruments translated without an additional validation process, or instruments validated in another format). To deal with these limitations, this study tested the psychometric properties of the Spanish paper-and-pencil and online versions of the Sexual Addiction Screening Test (SAST). Met…

Sexual addictionAdultMale050103 clinical psychologyFull-length ReportPsychometricsAdolescentPsychometricsmedia_common.quotation_subjectSexual BehaviorMedicine (miscellaneous): Traitement & psychologie clinique [H13] [Sciences sociales & comportementales psychologie]psychometric properties: Treatment & clinical psychology [H13] [Social & behavioral sciences psychology]compulsive sexual behavior03 medical and health sciencesYoung Adult0302 clinical medicinemedicineHumans0501 psychology and cognitive sciencesYoung adultPathologicalmedia_commonPsychiatric Status Rating ScaleshypersexualityIncidence (epidemiology)Addiction05 social sciencesReproducibility of ResultsGeneral Medicinemedicine.disease030227 psychiatrySpanish validationBehavior AddictivePsychiatry and Mental healthClinical PsychologySexual desireSexual Addiction Screening Test (SAST)HypersexualityFemalemedicine.symptomPsychologyClinical psychology
researchProduct

A method for quantifying atrial fibrillation organization based on wave-morphology similarity

2002

A new method for quantifying the organization of single bipolar electrograms recorded in the human atria during atrial fibrillation (AF) is presented. The algorithm relies on the comparison between pairs of local activation waves (LAWs) to estimate their morphological similarity, and returns a regularity index (/spl rho/) which measures the extent of repetitiveness over time of the detected activations. The database consisted of endocardial data from a multipolar basket catheter during AF and intraatrial recordings during atrial flutter. The index showed maximum regularity (/spl rho/=1) for all atrial flutter episodes and decreased significantly when increasing AF complexity as defined by W…

Signal processingBundle of Hismedicine.medical_specialtyMorphological similarityAtrial fibrillation (AF)Biomedical EngineeringSensitivity and SpecificityPattern Recognition AutomatedElectrocardiographySimilarity (network science)Heart RateInternal medicineAtrial Fibrillationotorhinolaryngologic diseasesmedicineHumansClinical treatmentWaveform morphologyMathematicsmedicine.diagnostic_testMinimum distanceModels CardiovascularReproducibility of ResultsSignal Processing Computer-AssistedAtrial fibrillationEndocardial signalmedicine.diseaseTachyarrhythmia organizationCardiologysense organsRhythm classificationBasket catheterElectrocardiographyAlgorithmsAtrial flutterBiomedical engineeringIEEE Transactions on Biomedical Engineering
researchProduct

An Automatic System for the Analysis and Classification of Human Atrial Fibrillation Patterns from Intracardiac Electrograms

2008

This paper presents an automatic system for the analysis and classification of atrial fibrillation (AF) patterns from bipolar intracardiac signals. The system is made up of: 1) a feature- extraction module that defines and extracts a set of measures potentially useful for characterizing AF types on the basis of their degree of organization; 2) a feature-selection module (based on the Jeffries-Matusita distance and a branch and bound search algorithm) identifying the best subset of features for discriminating different AF types; and 3) a support vector machine technique-based classification module that automatically discriminates the AF types according to the Wells' criteria. The automatic s…

Signal processingComputer scienceFeature extractionBiomedical EngineeringFeature extraction and selectionFeature selectionSensitivity and SpecificityIntracardiac injectionPattern Recognition AutomatedArtificial IntelligenceSearch algorithmAtrial FibrillationmedicineHumansDiagnosis Computer-AssistedIntracardiac ElectrogramArrhythmia organizationSignal processingmedicine.diagnostic_testbusiness.industrySupport vector machines (SVMs)Reproducibility of ResultsPattern recognitionAtrial fibrillationHuman atrial fibrillationmedicine.diseaseSupport vector machineSettore ING-INF/06 - Bioingegneria Elettronica E InformaticaAutomatic classificationArtificial intelligenceIntracardiac electrogrambusinessElectrocardiographyAlgorithmsIEEE Transactions on Biomedical Engineering
researchProduct

P300-based brain computer interface experimental setup

2009

A Brain-Computer interface (BCI) is a communication system that enables the generation of a control signal from brain signals such as sensorymotor rhythms and evoked potentials; therefore, it constitutes a novel communication option for people with severe motor disabilities (such as Amyotrophic Lateral Sclerosis patients). This paper presents the development of a P300-based BCI. This prototype uses a homemade six-channel electroencephalograph for the acquisition of the signals, and a visual stimulation matrix; since this matrix contains letters of the alphabet as well as images associated to them, it permits word-writing and the elaboration of messages with the images. To process the signal…

Signal processingmedicine.diagnostic_testComputer scienceSpeech recognitionInterface (computing)BrainReproducibility of ResultsElectroencephalographyElectroencephalographyLinear discriminant analysisEvent-Related Potentials P300Sensitivity and SpecificityLeast squaresUser-Computer InterfacePattern Recognition VisualmedicineAlgorithmsVisual CortexBrain–computer interface2009 Annual International Conference of the IEEE Engineering in Medicine and Biology Society
researchProduct

Quantification of synchronization during atrial fibrillation by Shannon entropy: Validation in patients and computer model of atrial arrhythmias

2005

Atrial fibrillation (AF), a cardiac arrhythmia classically described as completely desynchronized, is now known to show a certain amount of synchronized electrical activity. In the present work a new method for quantifying the level of synchronization of the electrical activity recorded in pairs of atrial sites during atrial fibrillation is presented. A synchronization index (Sy) was defined by quantifying the degree of complexity of the distribution of the time delays between sites by Shannon entropy estimation. The capability of Sy to discriminate different AF types in patients was assessed on a database of 60 pairs of endocardial recordings from a multipolar basket catheter. The analysis…

Signal processingmedicine.medical_specialtyTime delaysPhysiologyEntropyBiomedical EngineeringBiophysicsSensitivity and SpecificitySynchronizationHeart Conduction SystemArrhythmia (mechanisms)Internal medicinePhysiology (medical)medicineHumansIn patientDiagnosis Computer-AssistedMathematicsBody Surface Potential MappingModels CardiovascularCardiac arrhythmiaReproducibility of ResultsAtrial fibrillationAtrial arrhythmiasComputer simulationmedicine.diseaseAtrial fibrillationElectrophysiologyElectrophysiologymedicine.anatomical_structureBiophysicCardiologyRight atriumAlgorithms
researchProduct

Timing performance of the silicon PET insert probe

2010

Simulation indicates that PET image could be improved by upgrading a conventional ring with a probe placed close to the imaged object. In this paper, timing issues related to a PET probe using high-resistivity silicon as a detector material are addressed. The final probe will consist of several (four to eight) 1-mm thick layers of silicon detectors, segmented into 1 x 1 mm(2) pads, each pad equivalent to an independent p + nn+ diode. A proper matching of events in silicon with events of the external ring can be achieved with a good timing resolution. To estimate the timing performance, measurements were performed on a simplified model probe, consisting of a single 1-mm thick detector with 2…

SiliconMaterials scienceSiliconPhysics::Instrumentation and DetectorsTransducerschemistry.chemical_elementIntegrated circuitScintillatorTracking (particle physics)Sensitivity and Specificity01 natural sciencesLyso-030218 nuclear medicine & medical imaginglaw.invention03 medical and health sciences0302 clinical medicineOpticslaw0103 physical sciencesRadiology Nuclear Medicine and imagingDiodeRadiationCt Spect/Ct Pet/CtRadiological and Ultrasound Technology010308 nuclear & particles physicsbusiness.industryDetectorPublic Health Environmental and Occupational HealthReproducibility of ResultsEquipment DesignGeneral MedicineImage EnhancementEquipment Failure AnalysisTransducerchemistryPositron-Emission TomographybusinessRadiation Protection Dosimetry
researchProduct

Dosimetry comparison between TG-43 and Monte Carlo calculations using the Freiburg flap for skin high-dose-rate brachytherapy

2012

Abstract Purpose The purpose of this work was to evaluate whether the delivered dose to the skin surface and at the prescription depth when using a Freiburg flap applicator is in agreement with the one predicted by the treatment planning system (TPS) using the TG-43 dose-calculation formalism. Methods and Materials Monte Carlo (MC) simulations and radiochromic film measurements have been performed to obtain dose distributions with the source located at the center of one of the spheres and between two spheres. Primary and scatter dose contributions were evaluated to understand the role played by the scatter component. A standard treatment plan was generated using MC- and TG-43-based TPS appl…

Skin Neoplasmsmedicine.medical_treatmentBrachytherapyBrachytherapyMonte Carlo methodSensitivity and SpecificitySkin surfacemedicineHumansDosimetryRadiology Nuclear Medicine and imagingRadiochromic filmRadiation treatment planningSkinbusiness.industryRadiotherapy Planning Computer-AssistedReproducibility of ResultsRadiotherapy DosageEquipment DesignHigh-Dose Rate BrachytherapyComputational physicsEquipment Failure AnalysisOncologySPHERESNuclear medicinebusinessMonte Carlo MethodSoftwareBrachytherapy
researchProduct

A topology-constrained distance network algorithm for protein structure determination from NOESY data.

2005

This article formulates the multidi- mensional nuclear Overhauser effect spectroscopy (NOESY) interpretation problem using graph theory and presents a novel, bottom-up, topology-con- strained distance network analysis algorithm for NOESY cross peak interpretation using assigned resonances. AutoStructure is a software suite that implements this topology-constrained distance net- work analysis algorithm and iteratively generates structures using the three-dimensional (3D) protein structure calculation programs XPLOR/CNS or DY- ANA. The minimum input for AutoStructure in- cludes the amino acid sequence, a list of resonance assignments, and lists of 2D, 3D, and/or 4D-NOESY cross peaks. AutoStru…

Software suiteMagnetic Resonance SpectroscopybiologyProtein ConformationProteinsReproducibility of ResultsGraph theoryNuclear Overhauser effectCyanaModels TheoreticalNet (mathematics)biology.organism_classificationCrystallography X-RayBiochemistryProtein Structure SecondaryInterpretation (model theory)CrystallographyProtein structureStructural BiologyImage Processing Computer-AssistedMolecular BiologyTwo-dimensional nuclear magnetic resonance spectroscopyAlgorithmAlgorithmsMathematicsProteins
researchProduct