Search results for "Reproducibility"
showing 10 items of 1976 documents
Long-term stability study of clofarabine injection concentrate and diluted clofarabine infusion solutions
2011
Purpose: The aim of this study was to investigate the physicochemical stability of clofarabine (CAFdA) injection concentrate and ready-to-use CAFdA infusion solutions over a prolonged period of 28 days. Methods: To determine the stability of CAFdA infusion solutions, the injection concentrate (Evoltra®, 1 mg/mL, Genzyme) was diluted either with 0.9% sodium chloride or 5% glucose infusion solution. The resulting concentrations of 0.2 mg/mL or 0.6 mg/mL, respectively, were chosen to represent the lower and upper limit of the ordinary concentration range. Test solutions were stored under refrigeration (2–8°C) or at room temperature either light protected or exposed to light. CAFdA concentrati…
Respiratory mechanics measured by forced oscillations during mechanical ventilation through a tracheal tube
2011
The forced oscillation technique (FOT) allows the measurement of respiratory mechanics in the intensive care setting. The aim of this study was to compare the FOT with a reference method during mechanical ventilation through a tracheal tube. The respiratory impedance spectra were measured by FOT in nine anaesthetized pigs, and resistance and compliance were estimated on the basis of a linear resistance-compliance inertance model. In comparison, resistance and compliance were quantified by the multiple linear regression analysis (LSF) of conventional ventilator waveforms to the equation of motion. The resistance of the sample was found to range from 6 to 21 cmH(2)O s l(-1) and the compliance…
In-situ high spatial resolution LA-MC-ICPMS 230Th/U dating enables detection of small-scale age inversions in speleothems
2017
Abstract We present an in-situ method for Th and U isotope measurements by laser ablation multi-collector inductively coupled plasma mass spectrometry (LA-MC-ICPMS) to determine possible age inversions of stalagmites, using a 213 nm Nd:YAG laser connected to an MC-ICPMS. Due to the low ion beam intensity of 230 Th (20–120 counts per second, cps), we carefully optimized the operating parameters to get highest possible ion beam intensities, i.e., laser fluence (25 J cm −2 ), spot size (110 μm), pulse repetition rate (20 Hz), scan speed (4 μm s −1 ), integration time (1000 s), and He and Ar gas flow (∼0.9 L min −1 and ∼0.6 L min −1 respectively). A precision (2 relative standard error, 2RSE) o…
Comparative Analysis of Tagging and Feature-Tracking Cardiac MRI Techniques for the Evaluation of Cardiac Deformation
2020
[EN] Currently, there is a high prevalence of cardiovascular diseases, being the leading cause of mortality worldwide. Thus, a rapid and effective evaluation of the heart is increasingly relevant to diagnose the patient early and achieve appropriate treatment. For this reason, this study aims to compare myocardial deformation parameters such as circumferential strain (segmental, base, mid, apical and global) and global torsion values by the CMR tissue tagging reference technique in SPAMM cine images and the promising feature-tracking technique in b-SSFP cine images, in 31 healthy subjects and 35 patients diagnosed with infarct. The results obtained showed that there is a high agreement in t…
Elucidating the aryl hydrocarbon receptor antagonism from a chemical-structural perspective.
2020
The aryl hydrocarbon receptor (AhR) plays an important role in several biological processes such as reproduction, immunity and homoeostasis. However, little is known on the chemical-structural and physicochemical features that influence the activity of AhR antagonistic modulators. In the present report, in vitro AhR antagonistic activity evaluations, based on a chemical-activated luciferase gene expression (AhR-CALUX) bioassay, and an extensive literature review were performed with the aim of constructing a structurally diverse database of contaminants and potentially toxic chemicals. Subsequently, QSAR models based on Linear Discriminant Analysis and Logistic Regression, as well as two tox…
Testing experimental designs in liquid chromatography (II): Influence of the design geometry on the prediction performance of retention models.
2021
Abstract In liquid chromatography, the reliability of predictions carried out with retention models depends critically on the quality of the training experimental design. The search of the best design is more complex when gradient runs are used instead of isocratic experiments. In Part I of this work (JCA 1624 (2020) 461180), a general methodology based on the error propagation theory was developed and validated for assessing the quality of training designs involving gradients. The treatment relates the mathematical properties of a retention model with the geometry of the training designs and their subsequent predictions. In that work, only five usual designs were considered. Part II invest…
Estimation of significant solvent concentration ranges and its application to the enhancement of the accuracy of gradient predictions.
2004
Abstract The solvent concentration range actually useful for gradient predictions is significantly narrower than the total range scanned in a gradient run. This range, called “solvent informative range” (SIR), if known with the highest accuracy, allows to predict gradient retention times ( t g ) with minimal error. The small size of the SIR supports the application of the linear solvent strength theory (LSST). Furthermore, LSST allows a closed-form solution to the integral required to predict gradient retention times, which eliminates numerical integration, needed with other retention models. A methodology that calculates the SIR by applying error analysis, and uses it to improve the accura…
Detection, validation, and downstream analysis of allelic variation in gene expression.
2009
AbstractCommon sequence variants within a gene often generate important differences in expression of corresponding mRNAs. This high level of local (allelic) control—or cis modulation—rivals that produced by gene targeting, but expression is titrated finely over a range of levels. We are interested in exploiting this allelic variation to study gene function and downstream consequences of differences in expression dosage. We have used several bioinformatics and molecular approaches to estimate error rates in the discovery of cis modulation and to analyze some of the biological and technical confounds that contribute to the variation in gene expression profiling. Our analysis of SNPs and alter…
A compound-based proteomic approach discloses 15-ketoatractyligenin methyl ester as a new PPARγ partial agonist with anti-proliferative ability
2017
AbstractProteomics based approaches are emerging as useful tools to identify the targets of bioactive compounds and elucidate their molecular mechanisms of action. Here, we applied a chemical proteomic strategy to identify the peroxisome proliferator-activated receptor γ (PPARγ) as a molecular target of the pro-apoptotic agent 15-ketoatractyligenin methyl ester (compound 1). We demonstrated that compound 1 interacts with PPARγ, forms a covalent bond with the thiol group of C285 and occupies the sub-pocket between helix H3 and the β-sheet of the ligand-binding domain (LBD) of the receptor by Surface Plasmon Resonance (SPR), mass spectrometry-based studies and docking experiments. 1 displayed…