Search results for "Reproducibility"
showing 10 items of 1976 documents
The migration of femoral components after total hip replacement surgery: accuracy and precision of software-aided measurements.
2003
To assess the accuracy and precision of a software-aided system to measure migration of femoral components after total hip replacement (THR) on digitised radiographs.Subsidence and varus-valgus tilt of THR stems within the femur were measured on digitised anteroposterior pelvic radiographs. The measuring software (UMA, GEMED, Germany) relies on bony landmarks and comparability parameters of two consecutive radiographs. Its accuracy and precision were calculated by comparing it with the gold standard in migration measurements, radiostereometric analysis (RSA). Radiographs and corresponding RSA measurements were performed in 60 patients (38-69 years) following cementless THR surgery.The UMA s…
Hoffa’s fat pad thickness: a measurement method with sagittal MRI sequences
2021
Abstract Background Hoffa’s fat pad is a structure located within the fibrous joint capsule of the knee joint, but outside the synovial cavity. It plays an important biomechanical and metabolic role in knee joint, reducing the impact of forces generated by loading and producing cytokines. Changes in its size can induce modifications in the knee homeostasis. However, a great variability exists regarding its measurements. This work aims to evaluate the reliability of a measurement method of Hoffa’s fat pad dimensions through MRI. Methods 3T sagittal IW 2D TSE fat-suppressed MRI sequences, taken from the OAI (Osteoarthritis initiative) database, of 191 male and female patients, aged between 40…
An Optoelectronic System for Measuring the Range of Motion in Healthy Volunteers: A Cross-Sectional Study.
2019
Background and Objectives: Within the clinical evaluation of multiple pathologies of the lower limb, the measurement of range of motion (ROM) of its joints is fundamental. To this end, there are various tools, from the goniometer as a reference to more recent devices such as inclinometry-based applications, photo capture applications, or motion capture systems. This study aimed to assess the validity, intra-rater, and inter-rater reliability of the VeloFlex system (VS), which is a new camera-based tool designed for tracking joint trajectories and measuring joint ROM. Materials and Methods: Thirty-five healthy volunteers (16 females
Clinical performance of a highly portable, scanning calcaneal ultrasonometer.
2001
The aim of this study was to establish a normative database, assess precision, and evaluate the ability to identify women with low bone mass and to discriminate women with fracture from those without for a highly portable, scanning calcaneal ultrasonometer: the QUS-2. Fourteen hundred and one Caucasian women were recruited for the study. Among them were 794 healthy women 25–84 years of age evenly distributed per 10-year period to establish a normative database. Of these, 171 aged 25–34 years were defined as the young normal group for the purpose of T-score determination. Precision was assessed within 1 day (short-term) and over a 16-week period (long-term) in 79 women aged 25–84 years. Five…
Monitoring bone growth using quantitative ultrasound in comparison with DXA and pQCT.
2008
Quantitative ultrasound (QUS) is a safe, inexpensive, and nonradiation method for bone density assessment. QUS correlates with, and predicts fragility fractures comparable to, dual-energy X-ray absorptiometry (DXA)-derived bone mineral density (BMD) in postmenopausal women. However, its validity in monitoring bone growth in children is not well understood. Two hundred and fifty-eight 10-13 yr pubertal girls and 9 37-43 yr adults without diseases or history of medications known to affect bone metabolism were included in the 2-yr prospective study. Calcaneal broadband ultrasound attenuation (cBUA) was assessed using QUS-2 (Quidel, Santa Clara, CA), speed of sound of tibial shaft (tSOS) using …
Assessing Single Joints in Arthritis Clinical Trials
2009
The need to develop validated outcome measures to assess response to therapies in single joints has been recognized. In 2004, a task force was established to assess established and novel outcome measures in accordance with the OMERACT filter (truth, discrimination, and feasibility) for single joint assessment. This report describes the proceedings of the single joint assessment special interest group (SIG) at OMERACT 9, including an updated literature review of imaging of the knee joints, with a focus on the extent to which these modalities fulfill the OMERACT filter. A series of studies are reported that examine patient reported, clinical examination, and imaging outcomes in therapeutic st…
Novel Digital Technique to Quantify the Area and Volume of Cement Remaining and Enamel Removed after Fixed Multibracket Appliance Therapy Debonding: …
2020
The aim of this study was to construct a novel, repeatable, reproducible, and accurate measurement protocol for the area and volume of the remaining cement after removal of fixed multibracket appliances, the area and volume of remaining cement after cement removal, the area and volume of enamel removed after cement removal, and the volume of cement used to adhere fixed multibracket appliances. A total of 30 brackets were cemented and removed with over 30 extracted teeth embedded into three experimental models of epoxy resin. The models were scanned before and after bracket placement, bracket debonding, and polishing the remaining cement. The brackets were submitted to micro-computed tomogra…
Effect of saddle height on skin temperature measured in different days of cycling
2016
Infrared thermography can be useful to explore the effects of exercise on neuromuscular function. During cycling, it could be used to investigate the effects of saddle height on thermoregulation. The aim of this study was to examine whether different cycling postures, elicited by different knee flexion angles, could influence skin temperature. Furthermore, we also determined whether the reproducibility of thermal measurements in response to cycling differed in the body regions affected or not affected by saddle height. Sixteen cyclists participated in three tests of 45 min of cycling at their individual 50 % peak power output. Each test was performed in a different knee flexion position on …
Eight new mutations and the expanding phenotype variability in muscular dystrophy caused by ANO5.
2012
Objective: Description of 8 new ANO5 mutations and significant expansion of the clinical phenotype spectrum associated with previously known and unknown mutations to improve diagnostic accuracy. Methods: DNA samples of 101 patients in 95 kindreds at our quaternary referral center in Finland, who had undetermined limb-girdle muscular dystrophy (LGMD), calf distal myopathy, or creatine kinase (CK) elevations of more than 2,000 IU/L, were selected for ANO5 genetic evaluation, and the clinical findings of patients with mutations were retrospectively analyzed. Results: A total of 25 patients with muscular dystrophy caused by 11 different recessive mutations in the ANO5 gene were identified. The …
Measurement Properties of Smartphone Approaches to Assess Physical Activity in Healthy Young People: Systematic Review
2022
Background Physical inactivity is a preventable risk factor for several chronic diseases and one of the driving forces behind the growing global burden of disease. Recent evidence has shown that interventions using mobile smartphone apps can promote a significant increase in physical activity (PA) levels. However, the accuracy and reliability of using apps is unknown. Objective The aim of our review was to determine the accuracy and reliability of using mobile apps to measure PA levels in young people. We conducted a systematic review guided by PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses). Methods Studies published from 2007 to 2020 were sourced from 8 databa…