Search results for "Reproducibility"
showing 10 items of 1976 documents
Single region of interest versus multislice T2* MRI approach for the quantification of hepatic iron overload.
2011
Purpose To evaluate the effectiveness of the single ROI approach for the detection of hepatic iron burden in thalassemia major (TM) patients in respect to a whole liver measurement. Materials and Methods Five transverse hepatic slices were acquired by a T2* gradient-echo sequence in 101 TM patients and 20 healthy subjects. The T2* value was calculated in a single region of interest (ROI) defined in the medium-hepatic slice. Moreover, the T2* value was extracted on each of the eight ROIs defined in the functionally independent segments. The mean hepatic T2* value was calculated. Results For patients, the mean T2* values over segments VII and VIII were significantly lower. This pattern was su…
Improved T2* assessment in liver iron overload by magnetic resonance imaging.
2009
In the clinical MRI practice, it is common to assess liver iron overload by T2* multi-echo gradient-echo images. However, there is no full consensus about the best image analysis approach for the T2* measurements. The currently used methods involve manual drawing of a region of interest (ROI) within MR images of the liver. Evaluation of a representative liver T2* value is done by fitting an appropriate model to the signal decay within the ROIs vs. the echo time. The resulting T2* value may depend on both ROI placement and choice of the signal decay model. The aim of this study was to understand how the choice of the analysis methodology may affect the accuracy of T2* measurements. A softwar…
Evaluation of the efficacy of oral deferiprone in beta-thalassemia major by multislice multiecho T2*.
2006
Objectives: Oral deferiprone (L1) appears to be promising in the treatment of beta-thalassemia major (TM) patients. T2* magnetic resonance imaging (MRI) with a single measurement in the mid-ventricular septum was validated as a quantitative evaluation of myocardial iron overload. Previous studies suggested a marked heterogeneity of iron distribution in the myocardium. We set up a multislice multiecho T2* MRI for the detection of this heterogeneity. The aim of our study was to investigate differences between the L1 vs. the subcutaneous desferrioxamine (DF)-treated patients using this new approach.Methods: Thirty-six beta-TM patients (age 29 +/- 8 yr) underwent MRI. Eighteen patients received…
Evaluation of the anterior chamber angle in keratoconus and normal subjects.
2015
To evaluate the anterior chamber angle in keratoconus eyes by use of the Visante™ OCT and Orbscan™ II.Anterior chamber angle was measured with the Visante™ OCT and Orbscan™ II in 52 subjects, 26 KC subjects and 26 age and control subjects.When comparing the nasal and temporal angles obtained with the two techniques no correlation was found (R(2) always below 0.01) in either the control subjects or in the KC subjects. Despite this, there was an overall statistically significant difference in mean anterior chamber angles (p0.001) between Visante™ OCT and Orbscan™ II. There was no statistical difference (p0.05) between nasal and temporal anterior chamber angles when comparing controls and KC s…
Human isometric force production and electromyogram activity of knee extensor muscles in water and on dry land.
1999
This study was designed to determine trial-to-trial and day-to-day reproducibility of isometric force and electromyogram activity (EMG) of the knee extensor muscles in water and on dry land as well as to make comparisons between the two training conditions in muscle activity and force production. A group of 20 healthy subjects (12 women and 8 men) were tested three times over 2 weeks. A measurement session consisted of recordings of maximal and submaximal isometric knee extension force with simultaneous recording of surface EMG from the vastus medialis, vastus lateralis and biceps femoris muscles. To ensure identical measurement conditions the same patient elevator chair was used in both th…
Tidal Volume Estimation during Helmet Noninvasive Ventilation: an Experimental Feasibility Study
2019
AbstractWe performed a bench (BS) and human (HS) study to test the hypothesis that estimation of tidal volume (VT) during noninvasive helmet pressure support ventilation (nHPSV) would be possible using a turbine driven ventilator (TDV) coupled with an intentional leak single-limb vented circuit. During the BS a mannequin was connected to a lung simulator (LS) and at different conditions of respiratory mechanics, positive end expiratory pressure (PEEP) levels and leaks (30, 50 and 80 L/min). All differences were within the 95% limits of agreement (LoA) in all conditions in the Bland-Altman plot. The overall bias (difference between VT measured by TDV and LS) was 35 ml (95% LoA 10 to 57 ml), …
Objective measurement of intraocular forward light scatter using Hartmann-Shack spot patterns from clinical aberrometers. Model-eye and human-eye stu…
2007
Purpose To apply software-based image-analysis tools to objectively determine intraocular scatter determined from clinically derived Hartmann-Shack patterns. Setting Aston Academy of Life Sciences, Aston University, Birmingham, United Kingdom, and Department of Optics, University of Valencia, Valencia, Spain. Methods Purpose-designed image-analysis software was used to quantify scatter from centroid patterns obtained using a clinical Hartmann-Shack analyzer (WASCA, Zeiss/Meditec). Three scatter values, as the maximum standard deviation within a lenslet for all lenslets in the pattern, were obtained in 6 model eyes and 10 human eyes. In the model-eye sample, patterns were obtained in 4 sessi…
The Spanish-Version of the Subjective Vitality Scale: Psychometric Properties and Evidence of Validity.
2017
AbstractThe Subjective Vitality Scale (SVS) assess the subjective experience of being full of energy and alive, a clinically relevant outcome measure of positive psychological well-being. The purpose of this paper was to translate the 7-item SVS into Spanish and examine its psychometric properties. In Study 1 (n = 790 adolescents) and Study 2 (n = 130 athletes) reliability and exploratory factor analysis (EFA) were carried out. In Study 1 and Study 3 (n = 197 dancers) evidence of validity of inferences based on SVS scores estimating relationships with other variables (life satisfaction, global self-esteem and emotional and physical exhaustion) was obtained. In Study 2 invariance across time…
Validation of the Maslach Burnout Inventory-General Survey on a Representative Sample of Dominican Teachers: Normative Data
2016
AbstractBurnout is characterized by emotional exhaustion, depersonalization and lack of personal accomplishment (Bakke, Demerouti, & Sanz-Vergel, 2014). Several instruments for its measurement exist, but the most widely used scale for measuring its dimensions, by far, is the Maslach Burnout Inventory (MBI) in its different versions. Among the available versions of the scale, the MBI-General Survey was developed to measure three dimensions of burnout (cynicism, personal accomplishment, and emotional exhaustion) regardless of the type of work. The aim of this research is to offer evidence on the psychometric properties of the MBI-GS for its use in the Dominican Republic and other Caribbea…
Spanish Version of the Time Management Behavior Questionnaire for University Students
2012
The main objective of the study is to analyze the psychometric properties and predictive capacity on academic performance in university contexts of a Spanish adaptation of the Time Management Behavior Questionnaire. The scale was applied to 462 students newly admitted at the Universitat de València in the 2006-2007 school year. The analyses performed made it possible to reproduce the factorial structure of the original version of the questionnaire with slight modifications in the ascription of various ítems. The underlying factorial structure includes four interrelated dimensions (Establishing objectives and priorities, Time management tools, Perception of time control and Preference for di…