Search results for "Reproducibility"
showing 10 items of 1976 documents
Performance of a new device for the clinical determination of light discomfort
2020
PURPOSE To assess the performance of a new device for the clinical determination of light discomfort on a large sample of healthy human subjects. METHODS A total of 489 subjects ranging from 20 to 70 years old (241 men, 248 women) were evaluated with the LUMIZ™ 100 to determine light discomfort. Repeatability was assessed by means of within-subject standard deviation, coefficient of variation (CoV), and intraclass correlation coefficient (ICC). Repeated measures ANOVA, Kruskal-Wallis, and correlation analysis were applied to test for differences between repeated measures, and effect of age on reliability. RESULTS Discomfort thresholds obtained are well distributed across the light intensity…
Comparison of Electrocochleography and Video Head Impulse Test findings in Vestibular Migraine and Ménière Disease: A Preliminary Study
2020
OBJECTIVES: To evaluate electrophysiological findings among patients with vestibular migraine (VM) and to compare them with those of patients suffering from definite Ménière disease (MD) without migraine. MATERIALS and METHODS: Twenty-one consecutive patients suffering from VM were enrolled; all subjects were selected according to the criteria proposed by the Bàràny Society for Neuro-otology. Each patient underwent a careful otological and neurotological examination. After completing a questionnaire regarding migraine and vertigo complaints, they were assessed by audiometric testing, video head impulse test (vHIT), and elec-trocochleography (EcochG). Data were compared with those of 21 pati…
Validity and reliability of the Migraine-Treatment Optimization Questionnaire.
2009
Our aim was to establish the validity and reliability of a patient-rated Migraine Treatment Optimization Questionnaire (M-TOQ in primary care. Patients who met International Classification of Headache Disorders, 2nd edn criteria for migraine completed a 19-item questionnaire containing candidate items for the M-TOQ and three questionnaires designed to test convergent/construct validity [Migraine Disability Assessment Scale (MIDAS), Headache Impact Test (HIT)-6 and Migraine-Specific Quality of Life Scale (MSSQoL)]. A 15-item (M-TOQ15) and a five-item (M-TOQ-5) questionnaire were derived. Two hundred and fifty-three adult patients were recruited. Five treatment optimization domains were iden…
Assessing decentering: validation, psychometric properties, and clinical usefulness of the Experiences Questionnaire in a Spanish sample.
2014
Decentering is defined as the ability to observe one’s thoughts and feelings in a detached manner. The Experiences Questionnaire (EQ) is a self-report instrument that originally assessed decentering and rumination. The purpose of this study was to evaluate the psychometric properties of the Spanish version of EQ-Decentering and to explore its clinical usefulness. The 11-item EQ-Decentering subscale was translated into Spanish and psychometric properties were examined in a sample of 921 adult individuals, 231 with psychiatric disorders and 690 without. The subsample of nonpsychiatric participants was also split according to their previous meditative experience (meditative participants, n = 3…
Multiple sclerosis severity score: Using disability and disease duration to rate disease severity
2005
Background: There is no consensus method for determining progression of disability in patients with multiple sclerosis (MS) when each patient has had only a single assessment in the course of the disease. Methods: Using data from two large longitudinal databases, the authors tested whether cross-sectional disability assessments are representative of disease severity as a whole. An algorithm, the Multiple Sclerosis Severity Score (MSSS), which relates scores on the Expanded Disability Status Scale (EDSS) to the distribution of disability in patients with comparable disease durations, was devised and then applied to a collection of 9,892 patients from 11 countries to create the Global MSSS. I…
Italian version of the Chicago multiscale depression inventory: translation, adaptation and testing in people with multiple sclerosis.
2004
Depression is the commonest psychiatric disturbance in people with multiple sclerosis (MS), with prevalence higher than in the general population and other chronic diseases. However, accurate assessment of depressive symptoms can be biased by somatic symptoms which are part of both MS and depression. We translated and adapted into Italian the Chicago multiscale depression inventory (CMDI) and assessed its acceptability, internal consistency and test-retest reliability in 213 MS outpatients and 213 individually matched healthy controls. The questionnaire was also tested in 32 people with major depression. Acceptability, internal consistency, and test-retest reliability were good overall. We …
Reliability of knee extension and flexion measurements using the Con-Trex isokinetic dynamometer.
2007
The aim of this study was to evaluate the reliability of isokinetic and isometric assessments of the knee extensor and the flexor muscle function using the Con-Trex isokinetic dynamometer. Thirty healthy subjects (15 males, 15 females) were tested and retested 7 days later for maximal strength (isokinetic peak torque, work, power and angle of peak torque as well as isometric maximal voluntary contraction torque and rate of torque development) and fatigue (per cent loss and linear slope of torque and work across a series of 20 contractions). For both the knee extensor and the flexor muscle groups, all strength data - except angle of peak torque - demonstrated moderate-to-high reliability, wi…
Semi-automated retinal vessel analysis in nonmydriatic fundus photography.
2013
Purpose Funduscopic assessment of the retinal vessels may be used to assess the health status of microcirculation and as a component in the evaluation of cardiovascular risk factors. Typically, the evaluation is restricted to morphological appreciation without strict quantification. Our purpose was to develop and validate a software tool for semi-automated quantitative analysis of retinal vasculature in nonmydriatic fundus photography. Methods matlab software was used to develop a semi-automated image recognition and analysis tool for the determination of the arterial–venous (A/V) ratio in the central vessel equivalent on 45° digital fundus photographs. Validity and reproducibility of the r…
Comparison of partial coherence interferometry and ultrasound for anterior segment biometry.
2008
To assess the performance of a partial coherence interferometry (PCI)-based device for the determination of anterior segment biometry.Clinica Centrofama, Cartagena, Murcia, Spain.Central corneal thickness (CCT), anterior chamber depth (ACD), and lens thickness (LT) were measured with the ACMaster PCI anterior segment biometer and an Echoscan US-1800 ultrasound (US) biometer/pachymeter with and without cycloplegia. To determine the precision of the instruments, the same examiner took 30 consecutive CCT, ACD, and LT measurements in a single subject under the same conditions and with and without cycloplegia. The same measurements were performed in additional subjects.Twenty-one eyes (16 subjec…
The symptom check-list, SCL-90-R: its use and characteristics in chronic pain patients
2000
The SCL-90-R is a widely-used questionnaire for self-report of psychological distress and multiple aspects of psychopathology, as part of the evaluation of chronic pain patients and other non-psychiatric populations. The aim of this study is the presentation of clinical results of this multidimensional questionnaire in a convenience sample of 3540 chronic pain patients treated in a multidisciplinary pain centre. Confirmatory Factor Analysis (CFA), Exploratory Factor Analysis (EFA), single scale factor analyses and Cronbach's alphas are used to assess the internal structure and correlation to other instruments (CES-D, STAI, MPSS) to assess construct validity. It is shown that the 9 dimension…