Search results for "Reproducibility"
showing 10 items of 1976 documents
Self-Other Differentiation Scale: Dimensionality, IRT Parameterization, and Measurement Invariance
2018
The Self-Other Differentiation Scale (Olver, Aries, & Batgos, 1989) is a self-report instrument assessing the experience of a separate sense of self from others. The authors aimed to examine its dimensionality, reliability, and measurement invariance across gender. It was completed by 348 participants (48% men) from 17 to 30 years old in Study 1, 348 participants (40% men) from 18 to 28 years old in Study 2, and 1,068 participants (49% men) from 17 to 28 years old in Study 3. The results supported the hypothesis of just one factor underlying the scale; they also showed an appropriate internal consistency and a partial measurement invariance across gender. Results also showed evidence fo…
Sociodemographic factors in fibromyalgia: results from the Italian Fibromyalgia Registry
2022
ObjectiveFibromyalgia (FM) is a chronic musculoskeletal pain syndrome of unknown aetiopathogenesis. Its development and maintenance are related to the interplay of biological, psychological, and contextual factors. Among the contextual factors, sociodemographic aspects are poorly elucidated. This study aimed to evaluate the relationships between sociodemographic/ clinical factors and symptom severity measures using a web-based registry of patients with FM.MethodsAdult patients with an ACR 2010/2011 diagnosis of FM underwent a clinical evaluation and were asked to complete questionnaires covering their sociodemographic data (gender, age, marital status, educational level), and disease-specif…
Validity of the International Physical Activity Questionnaire Long Form for Assessing Physical Activity and Sedentary Behavior in Subjects with Chron…
2021
Validation studies of questionnaires used to assess physical activity (PA) and sedentary behavior (SB) in stroke survivors are scarce. This cross-sectional study aimed to examine the validity of the International Physical Activity Questionnaire long-form (IPAQ-LF) in community living adults with post-stroke sequelae (≥6 months) and preserved ambulation. Participants’ functional mobility, lower limb strength, ambulatory level, stroke severity, and disability were assessed. An accelerometer (ActiGraph GT3X+) was worn for ≥7 consecutive days. Subsequently, the IPAQ-LF was interview-administered. Fifty-six participants (58.1 ± 11.1 years, 66.1% male) were included. A strong correlation between …
The reliability of measuring medial gastrocnemius muscle-tendon unit lengths during gait
2021
Background Ultrasound imaging combined with 3D motion analysis allows for in-vivo assessment of muscle-tendon unit lengths during gait. The clinical relevance of analysing the medial gastrocnemius (MG) and Achilles muscle-tendon junction (MTJ), MG mid-muscle belly fascicles (FAS) and muscle thickness was shown. However, their reliability error estimations over the gait cycle is unknown. Research question What are the intra- and inter-session errors associated with extracting MG belly, thickness, FAS and tendon lengths using ultrasound during gait in healthy participants? Methods 3D gait analysis was carried out in ten healthy adults as they walked on an instrumented treadmill at a comfortab…
Blood flow velocity waveforms of the fetal middle cerebral artery in a normal population: reference values from 18 weeks to 42 weeks of gestation
2002
The aim of this prospective cross-sectional study was to establish new Doppler reference curves for peak blood flow velocities (Vmax, Vmean, Vmin) and impedance indices (PI, RI) of the middle cerebral artery at 18-42 weeks of gestation by an automatic wave form analysis integrated into the ultrasound device. In 962 low-risk pregnancies, blood flow velocities were derived from the middle cerebral artery with pulsed color Doppler ultrasonography. Reference curves were constructed for the individual parameters based on a growth function from a four-parameter class of monotonic continuous functions according to the smallest square principle for maximum blood flow velocities, as well as on a pol…
Testing Frequency-Domain Causality in Multivariate Time Series
2010
We introduce a new hypothesis-testing framework, based on surrogate data generation, to assess in the frequency domain, the concept of causality among multivariate (MV) time series. The approach extends the traditional Fourier transform (FT) method for generating surrogate data in a MV process and adapts it to the specific issue of causality. It generates causal FT (CFT) surrogates with FT modulus taken from the original series, and FT phase taken from a set of series with causal interactions set to zero over the direction of interest and preserved over all other directions. Two different zero-setting procedures, acting on the parameters of a MV autoregressive (MVAR) model fitted on the ori…
Nasal airway in cleft-palate patients: acoustic rhinometric data
1997
The objective of this study was to investigate an instrumental assessment technique for acquiring reproducible, metric data on the nasal airway in cleft-palate associated nasal dysplasia. A consecutive sample of 23 unilateral, 17 bilateral CLP patients and 15 controls with subjective normal nasal patency from a cleft-palate rehabilitation centre were studied. A series of transnasal acoustic measurements (pressure wave: 55 dB for 2 ms) of nasal volume were performed before and after topical decongestion with 2 x 0.3 mg of xylometazoline. A standardized regimen of acoustic parameters of the nasal valve and the adjacent segment of the nasal cavity were calculated. The cleft side yielded a sign…
Autoantibodies in breast cancer: their use as an aid to early diagnosis
2007
There is increasing evidence that the immune system produces a humoral response to cancer-derived antigens. This study assessed the diagnostic potential of autoantibodies to multiple known tumour-associated proteins.Sera from normal controls (n = 94), primary breast cancer patients (n = 97) and patients with ductal carcinoma in situ (DCIS) (n = 40) were investigated for the presence of autoantibodies to p53, c-myc, HER2, NY-ESO-1, BRCA1, BRCA2 and MUC1 antigens by enzyme-linked immunosorbent assay.Reproducibly elevated levels of autoantibodies were seen in at least one of the six antigens in 64% of primary breast cancer patient sera and 45% of patients with DCIS at a specificity of 85%. No …
Reference Ranges and Distribution of Placental Volume by 3-Dimensional Virtual Organ Computer-Aided Analysis Between 11 Weeks and 13 Weeks 6 Days
2013
OBJECTIVES The purpose of this study was to determine the feasibility, reproducibility, and distribution of placental volume measurements according to the crown-rump length between 11 weeks and 13 weeks 6 days. METHODS Images were acquired in 128 pregnancies followed in Burgundy during first-trimester screening sonography using an abdominal 3-dimensional transducer. The placental volume was then calculated by the virtual organ computer-aided analysis method with a rotation angle of 30° by a single operator. RESULTS Placental volumes ranged from 33.3 to 107.6 cm(3) with a mean ± SD of 62.3 ± 14.8 cm(3); the 5th and 10th percentiles were 38.0 and 44.20 cm(3), respectively, whereas the 90th an…
Self- and observer assessment in anxiolytic drug trials: A comparison of their validity
1990
Self-rating scales are considered to be less useful for comparing different treatments in anxiety patients than observer-rating scales. However, the empirical evidence for this assumption is not adequate. A self-rating inventory of 35 items related to anxiety was perfectly parallel with an observer-rating inventory. Both instruments were used in the Cross National Collaborative Panic Study to compare the efficacy of imipramine, alprazolam and placebo in an 8-week drug trial in a sample of 1168 outpatients. The variance of the self-rating assessments was about two times higher. Both scales were equally sensitive to change; however, the measurement of change by means of the self-rating scale …