Search results for "Reproducibility"

showing 10 items of 1976 documents

Development of a GC–MS/MS strategy to determine 15 mycotoxins and metabolites in human urine

2014

The widespread mycotoxins contamination of food commodities has made the monitoring of their levels essential. To overcome the disadvantages of the indirect approach by food analysis, detection of mycotoxin as biomarkers in urine provides a useful and specific data for exposure assessment to these food contaminants. In this work, a sensitive, rapid and accurate method based on gas chromatography-tandem mass spectrometry procedure to determine 15 mycotoxins and metabolites in human urine was optimized and validated taking into consideration the guidelines specified in Commission Decision 2002/657/EC and 401/2006/EC. A salting-out assisted acetonitrile-based extraction was used for sample pre…

AcetonitrilesChromatographyChemistryExtraction (chemistry)Reproducibility of ResultsFood ContaminationGuidelines as TopicUrineMycotoxinsContaminationGas Chromatography-Mass SpectrometryFood AnalysisAnalytical Chemistrychemistry.chemical_compoundReference ValuesTandem Mass SpectrometryCalibrationHumansSample preparationGas chromatography–mass spectrometryChildMycotoxinBiomarkersFood contaminantTalanta
researchProduct

Multi-mycotoxin analysis in wheat semolina using an acetonitrile-based extraction procedure and gas chromatography–tandem mass spectrometry

2012

A new analytical method for the rapid and simultaneous determination of ten mycotoxins including patulin, zearalenone and eight trichothecenes (nivalenol, fusarenon-X, diacetoxyscirpenol, 3-acetyl-deoxynivalenol, neosolaniol, deoxynivalenol, T-2 and HT-2) in wheat semolina has been developed and optimized. Sample extraction and purification were performed with a modified QuEChERS-based (acronym of Quick, Easy, Cheap, Effective, Rugged and Safe) procedure and determined by gas chromatography (GC) coupled to triple quadrupole instrument (QqQ). This is the first paper on the application of GC-QqQ-MS/MS to analysis of mycotoxins. Careful optimization of the gas chromatography-tandem mass spectr…

AcetonitrilesChromatographyGas Chromatography/Tandem Mass SpectrometryCalibration curveFlourLiquid-Liquid ExtractionOrganic ChemistryAnalytical chemistryReproducibility of ResultsGeneral MedicineHydrogen-Ion ConcentrationMycotoxinsQuechersSensitivity and SpecificityBiochemistryGas Chromatography-Mass SpectrometryDiacetoxyscirpenolAnalytical ChemistryTriple quadrupole mass spectrometerPatulinchemistry.chemical_compoundchemistryTandem Mass SpectrometryGas chromatographyGas chromatography–mass spectrometryJournal of Chromatography A
researchProduct

Determination of free formaldehyde in cosmetics containing formaldehyde-releasing preservatives by reversed-phase dispersive liquid-liquid microextra…

2017

Abstract An analytical method for the determination of traces of formaldehyde in cosmetic products containing formaldehyde-releasing preservatives has been developed. The method is based on reversed-phase dispersive liquid–liquid microextraction (RP-DLLME), that allows the extraction of highly polar compounds, followed by liquid chromatography–ultraviolet/visible (LC–UV/vis) determination with post-column derivatization. The variables involved in the RP-DLLME process were studied to provide the best enrichment factors. Under the selected conditions, a mixture of 500 μL of acetonitrile (disperser solvent) and 50 μL of water (extraction solvent) was rapidly injected into 5 mL of toluene sampl…

AcetonitrilesLiquid Phase Microextraction02 engineering and technologyCosmetics01 natural sciencesBiochemistryChemistry Techniques AnalyticalAnalytical Chemistrychemistry.chemical_compoundLimit of DetectionFormaldehydeAcetonitrileDerivatizationDetection limitChromatographyElution010401 analytical chemistryOrganic ChemistryExtraction (chemistry)Preservatives PharmaceuticalReproducibility of ResultsWaterGeneral Medicine021001 nanoscience & nanotechnology0104 chemical sciencesSolventchemistryReagentSolvents0210 nano-technologyEnrichment factorChromatography LiquidTolueneJournal of chromatography. A
researchProduct

Optimised procedures for the reversed-phase liquid chromatographic analysis of formulations containing tricyclic antidepressants.

2003

The chromatographic behaviour (retention, selectivity, peak shape and resolution) of seven tricyclic antidepressants (TCAs), amitryptiline, clomipramine, doxepin, imipramine, maprotiline, nortryptiline and trimipramine, was examined. Conventional unendcapped Cs and C18 columns and an endcapped XTerra MS C18 column recommended for the analysis of basic compounds were used together with acetonitrile-water and micellar sodium dodecylsulfate (SDS)-pentanol mobile phases. The two best combinations were XTerra C18/acetonitrile, which yielded the largest efficiencies and resolution, and C8/SDS-pentanol, which eliminated the peak tails that were still observed with the XTerra C18 column. Both the s…

AcetonitrilesResolution (mass spectrometry)Clinical BiochemistryPharmaceutical ScienceCapsulesAntidepressive Agents TricyclicSensitivity and SpecificityDosage formAnalytical Chemistrychemistry.chemical_compoundDrug DiscoverymedicineAcetonitrileSpectroscopyChromatography High Pressure LiquidChromatographyExtraction (chemistry)Reproducibility of ResultsReversed-phase chromatographyDoxepinTrimipraminechemistry1-PentanolSolventsmedicine.drugTabletsJournal of pharmaceutical and biomedical analysis
researchProduct

Chemical initiation for butyl and lauryl acrylate monolithic columns for CEC.

2009

Butyl acrylate (BA)- and lauryl acrylate (LA)-based monolithic stationary phases for CEC were synthesized, using a redox system as initiator of polymerization. BA monoliths were initiated with ammonium peroxodisulfate, whereas LA columns were obtained with lauroyl peroxide as initiator. In both cases, TEMED was used to activate the process. The influence of porogenic solvent composition on both morphological and electrochromatographic properties of the resulting monoliths was investigated. Excellent efficiencies (minimum plate heights of 4.2-6.3 microm for BA columns and 2.6-5.3 microm for LA stationary phases, for a PAHs mixture) were achieved. The capability of separation of both types of…

AcrylateLipid PeroxidesButyl acrylateClinical BiochemistryInorganic chemistryReproducibility of ResultsLauroyl peroxideEthylenediaminesBiochemistryRedoxAnalytical Chemistrychemistry.chemical_compoundchemistryPolymerizationAcrylatesAmmonium SulfateCapillary ElectrochromatographyMicroscopy Electron ScanningAmmoniumSolvent compositionPolycyclic Aromatic HydrocarbonsGonadal Steroid HormonesNuclear chemistryElectrophoresis
researchProduct

Development and validation of the SIMPLE endoscopic classification of diminutive and small colorectal polyps

2018

Abstract Background Prediction of histology of small polyps facilitates colonoscopic treatment. The aims of this study were: 1) to develop a simplified polyp classification, 2) to evaluate its performance in predicting polyp histology, and 3) to evaluate the reproducibility of the classification by trainees using multiplatform endoscopic systems. Methods In phase 1, a new simplified endoscopic classification for polyps – Simplified Identification Method for Polyp Labeling during Endoscopy (SIMPLE) – was created, using the new I-SCAN OE system (Pentax, Tokyo, Japan), by eight international experts. In phase 2, the accuracy, level of confidence, and interobserver agreement to predict polyp hi…

AdenomaMODULEValidation studymedicine.medical_specialtyConsensusDelphi TechniqueI-SCANColonoscopyColonic PolypsCOMMUNITY PRACTICE03 medical and health sciencesNarrow Band Imaging0302 clinical medicineEXPERTSPredictive Value of TestsOptical diagnosisADENOMASmedicineHumansHISTOLOGYObserver VariationReproducibilitymedicine.diagnostic_testbusiness.industryGastroenterologyReproducibility of ResultsColonoscopyCOLON POLYPSPredictive valueConfidence intervalEndoscopyTumor Burden030220 oncology & carcinogenesisPredictive value of testsAGREEMENTOPTICAL DIAGNOSIS030211 gastroenterology & hepatologyRadiologybusinessColorectal NeoplasmsEndoscopy
researchProduct

The learning curve, accuracy, and interobserver agreement of endoscope-based confocal laser endomicroscopy for the differentiation of colorectal lesi…

2012

Background: The endoscope-based confocal laser endomicroscopy (eCLE) system allows in vivo imaging of colorectal epithelium. Little is known about the learning curve for accurate interpretation of confocal images acquired with eCLE. Objective: To determine the learning curve of eCLE, its diagnostic accuracy, and the intra- and interobserver agreement for the differentiation of colorectal lesions. Design: Post hoc assessment of selected eCLE images. Setting: Academic centers. Patients: This study involved colonoscopic images from 47 patients. Main Outcome Measurements: Learning curve of eCLE, accuracy, and intraobserver and interobserver agreement. Methods: Three endoscopists received a shor…

AdenomaMalePathologymedicine.medical_specialtyendocrine systemFuture studiesObserver (quantum physics)EndoscopePost hocConfocalColonic PolypsSensitivity and SpecificitymedicineHumansRadiology Nuclear Medicine and imagingStage (cooking)AgedConfocal laser endomicroscopyObserver VariationChi-Square DistributionMicroscopy Confocalbusiness.industryCarcinomaGastroenterologyReproducibility of ResultsColonoscopyMiddle AgedLearning curveColitis UlcerativeFemalebusinessNuclear medicineColorectal NeoplasmsLearning CurveGastrointestinal endoscopy
researchProduct

Comparison of the yield from two faecal immunochemical tests at identical cutoff concentrations – a randomized trial in Latvia

2016

OBJECTIVE We have compared the performance of two faecal immunochemical tests (FIT) in an average-risk population. MATERIALS AND METHODS Altogether, 10 000 individuals aged 50-74 were selected randomly from the population of Latvia in 2011 and assigned randomly either to OC-Sensor or to FOB Gold single-time testing. Positivity of the test, frequency of colonic lesions, number needed to screen (NNscreen) and scope for the detection of an advanced neoplasm (cancer and advanced adenoma) were compared between the tests using the same cutoff concentrations in µg/g faeces. Confidence intervals (CIs) at 95% were calculated. RESULTS Positivity with the cutoff set at 10 µg/g faeces was 12.8% (95% CI…

AdenomaMalemedicine.medical_specialtyPopulationColonoscopyGastroenterologylaw.invention03 medical and health sciences0302 clinical medicineRandomized controlled trialPredictive Value of TestslawInternal medicineHumansMass ScreeningMedicineCutoffeducationFecesAgededucation.field_of_studyHepatologymedicine.diagnostic_testbusiness.industryGastroenterologyReproducibility of ResultsColonoscopyMiddle AgedImmunohistochemistryLatviaNumber needed to screenConfidence intervalOccult Blood030220 oncology & carcinogenesisPredictive value of testsFemale030211 gastroenterology & hepatologyColorectal NeoplasmsbusinessEuropean Journal of Gastroenterology & Hepatology
researchProduct

Interpretation of intraoperative parathyroid hormone monitoring according to the Rome criterion in primary hyperparathyroidism

2022

AbstractIntraoperative parathyroid hormone dosage allows real-time monitoring of the decrease in PTH levels during parathyroidectomy and verify procedure’s efficacy. Currently, none of the interpretative criteria used has absolute accuracy. The aim of this study is to evaluate diagnostic accuracy of the Rome criterion verifying diagnostic significance of the individual assays. A total of 205 patients with primary hyperparathyroidism from a single adenoma were retrospectively evaluated and monitored with baseline PTH, PTH at 10 min and PTH at 20 min after adenoma excision. The accuracy of the latter two assays compared with baseline was compared by ROC curves. In addition, was evaluated the …

AdenomaParathyroidectomyParathyroid NeoplasmsMultidisciplinaryParathyroid HormoneRomeHumansReproducibility of Resultsintraoperative parathyroid hormone monitoringprimary hyperparathyroidismHyperparathyroidism PrimaryRetrospective StudiesScientific Reports
researchProduct

Translation and Validation of a Brief Health Literacy Instrument for School-Age Children in a Danish Context

2022

Low health literacy (HL) is associated with adverse health behaviors and poor health, and brief, high-quality instruments for measuring HL in children are scarce. The Health Literacy for School-Aged Children (HLSAC) instrument is a 10-item theory-based and internationally validated tool for measuring HL. The purpose of this study was to translate and validate the HLSAC instrument among Danish school-aged children. The instrument was translated into Danish by a standardized forward-backward translation process, and then pre-tested for face validity with 61 pupils from four schools. Thereafter, the instrument was tested among 805 pupils in grades 6 to 7 (age 11–14 years) from 15 schools. Whe…

AdolescentPsychometricsDenmarkkäännöksetReproducibility of Resultslapset (ikäryhmät)General MedicineterveysosaaminenterveyslukutaitoHealth Literacymittausmenetelmätterveyden edistäminenterveyskäyttäytyminenmittarit (mittaus)HumansTranslationsstandarditChildterveys
researchProduct