Search results for "Resistivity"
showing 10 items of 385 documents
Seismic and non‐invasive geophysical surveys for the renovation project of Branciforte Palace in Palermo
2020
The renovation project of the historic Branciforte Palace (16th–17th century) in Palermo (Italy) was owned by the Banco di Sicilia Foundation, with the aim for it to become a multi-purpose centre for the promotion of exhibitions and cultural events. In the context of the restoration work, a multi-methodological and non-invasive geophysical study has been carried out. The seismic characterization of the foundation soils was obtained by means of joint interpretations of a vertical seismic profile (VSP), multichannel analysis of surface waves (MASW) and horizontal to vertical spectral ratio (HVSR) microtremor analysis. The mutually constrained inversion of seismic surveys carried out with diff…
An Overview of Geophysical Techniques and Their Potential Suitability for Archaeological Studies
2023
The need to study, protect, and conserve archaeological heritage has enhanced the application of geophysical techniques as non-invasive and reliable tools to investigate fragile and valuable assets. This review presents the most popular geophysical techniques suitable for archaeogeophysical investigations, namely, magnetometry, ground penetrating radar, and electrical resistivity tomography, together with a series of multiparametric measures taken from aerial platforms (UAS). For each method, we recall the basic physical principles, illustrate the operative procedures for field investigation, and provide indications about data processing and modeling. We propose a flowchart to address relia…
Space charge and induced dipole relaxation in solid electrolytes
1996
The space charge relaxation and induced dipole relaxation in solid electrolytes is discussed. The di-electric responses of these relaxations gives a satisfactory fit to the universal conductivity behaviours in the frequency range from DC to infrared.
The Electrical Properties of Ba1-ySryZrxTi1-xO3Solid Solution
2011
A lead-free solid solution Ba0.80Sr0.20Ti0.75Zr0.25O3 was prepared by a conventional technology. The structure and morphology of investgated samples were characterised by X-ray diffraction (XRD) and scanning electron microscopy (SEM). The studies of electric conductivity were performed depending on temperature and frequency of electric measuring field. The activation energy was calculated from the Arrhenius plots.
Effect of Zr4+Doping on the Electrical Properties of BaTiO3Ceramics
2011
The BaZrxTi1-xO3 for 0⩽x⩽15 ceramics were prepared by a conventional solid state reaction method and were determined by an X-ray diffraction (XRD) and scanning electron microscopy (SEM) for crystallographic, surface morphological and compositional studies. A single phase with perovskite structure was identified in the samples at room temperature. No significant impurities were detected in an EDS spectrum and the samples are in good stoichiometric ratio. The temperature dependence of electric conductivity was evaluated in the temperature range from 300 to 550 K for a selected frequency by a HP4284 LCR meter. The activation energy was calculated from the Arrhenius plots.
A Fast Imaging Technique Applied to 2D Electrical Resistivity Data
2014
A new technique is proposed to process 2D apparent resistivity datasets, in order to obtain a fast and contrasted resistivity image, useful for a rapid data check in field or as a starting model to constrain the inversion procedure. In the past some modifications to the back-projection algorithm, as well as the use of filtering techniques for the sensitivity matrix were proposed. An implementation of this technique is proposed here, considering a two-step approach. Initially a damped least squares solution is obtained after a full matrix inversion of the linearized geoelectrical problem. Furthermore, on the basis of the results, a subsequent filtering algorithm is applied to the Jacobian ma…
Electrical conductivity of magma in the course of crystallization controlled by their residual liquid composition.
2005
International audience; The electrical conductivity of a magma in the course of crystallization was experimentally investigated in the temperature range of 1350–1018°C. Large samples of basaltic composition with a homogeneous crystal content were synthesized in a gas mixing furnace at 1 atm pressure. The samples were analyzed by electron microprobe. The relative proportions of the phases as a function of temperature were determined. Depending on temperature, the phase assemblies included quenched silicate liquid, ±plagioclase, ±pyroxene, ±Fe-Ti oxides. The crystal content varied from 0 to 80 wt %. In response to partial crystallization, the residual liquid changed composition from basalt, t…
An analysis of VLF electric field spectra measured in Titan's atmosphere by the Huygens probe
2009
[1] A numerical simulation of Titan's electromagnetic cavity in the VLF band is carried out using the Transmission Line Matrix (TLM) method, with the aim of assessing the VLF electric field spectra sent by the Huygens probe. In an Earth-like model, successive peaks would be expected in the spectra, associated with multiple reflections of the electromagnetic wave on the external surfaces of Titan's electromagnetic cavity, formed by the ionosphere and a conductive ground or underground surface. However, owing to high losses conferred by the electrical conductivity to Titan's atmosphere, the direct numerical and experimental spectra are decreasing functions of the frequency without resonances …
Inverse problem for tripotential measures in the study of buried cavities
1996
This paper presents a solution to the inverse electrical problem for the interpretation of apparent resistivity anomalies due to empty buried cavities of quasi-spherical shape when tripotential measures are carried out. The anomalies of the apparent resistivities ra,rb andrg,and the composed resistivitiesrmand rt were previously calculated for a sufficient class of spherical models of resistivity anomalies. Then, for the whole class of models, some functionals of spatial distribution of the apparent and composed resistivity were identified and analyzed. They represent the average characteristics of the anomalies and, depending in a simple way on the fundamental parameters of the sources of …
Archaeological excavation confirms the geophysical anomalies recorded at the cathedral of tarragona - A comparative study
2011
An integrated geophysical survey was conducted in September 2007 at the Cathedral of Tarragona to search for archaeological remains of the Roman temple dedicated to the Emperor Augustus. Many hypotheses about its location have been put forward, the most recent ones suggesting it could be inside the present cathedral. A project including Electrical resistivity tomography (ERT) and Ground probing radar (GPR) was planned for a year and conducted during a week of intensive field survey. Both ERT and GPR provided detailed information about subsoil structures. Different ERT techniques and arrays were used, ranging from standard Wenner-Schlumberger 2D sections to full 3D electrical imaging using t…