Search results for "Reso"

showing 10 items of 13841 documents

Effects of magnetic configuration on hot electrons in a minimum-B ECR plasma

2020

International audience; To investigate the hot electron population and the appearance of kinetic instabilities in highly charged electron cyclotron resonance ion source (ECRIS), the axially emitted bremsstrahlung spectra and microwave bursts emitted from ECRIS plasma were synchronously measured on SECRAL-II (Superconducting ECR ion source with Advanced design in Lanzhou No. II) ion source with various magnetic field configurations. The experimental results show that when the ratio of the minimum field to the resonance field (i.e. Bmin/Becr ) is less than ~0.8, the bremsstrahlung spectral temperature Ts increases linearly with the Bmin/Becr –ratio when the injection, extraction and radial mi…

010302 applied physicsPhysics[PHYS.PHYS.PHYS-ACC-PH]Physics [physics]/Physics [physics]/Accelerator Physics [physics.acc-ph]Cyclotron resonanceBremsstrahlungResonancePlasmaCondensed Matter Physics01 natural sciencesElectromagnetic radiationElectron cyclotron resonance010305 fluids & plasmasMagnetic fieldNuclear Energy and Engineering0103 physical sciencesAtomic physicsMicrowave
researchProduct

Fundamental Noise Limits and Sensitivity of Piezoelectrically Driven Magnetoelastic Cantilevers

2020

International audience; Magnetoelastic sensors for the detection of low-frequency and low-amplitude magnetic fields are in the focus of research for more than 30 years. In order to minimize the limit of detection (LOD) of such sensor systems, it is of high importance to understand and to be able to quantify the relevant noise sources. In this contribution, cantilever-type electromechanical and magnetoelastic resonators, respectively, are comprehensively investigated and mathematically described not only with regard to their phase sensitivity but especially to the extent of the sensor-intrinsic phase noise. Both measurements and calculations reveal that the fundamental LOD is limited by addi…

010302 applied physicsPhysics[SPI.OTHER]Engineering Sciences [physics]/OtherCantileverMagnetic domainMechanical EngineeringAcousticsMagnetostriction02 engineering and technology021001 nanoscience & nanotechnology01 natural sciencesMagnetic fieldVibrationResonatorMagnet0103 physical sciencesPhase noiseElectrical and Electronic Engineering0210 nano-technology
researchProduct

Control flow strategy in a receiver coil for nuclear magnetic resonance for imaging

2020

A mathematical discussion is introduced to describe the receiver coil characterizing a nuclear magnetic resonance for imaging, starting from a general shape of the conductor. A set of different inductance calculations have been introduced, varying the shape of the conductor. The inductance calculation led to a general expression of the magnetic field of a single coil characterized by a rectangular shape. A dynamic model of the receiver coil has been developed to represent the natural frequencies that characterize the operational bandwidth. A nonstationary control strategy is implemented to make a real time changing of the operational bandwidth. The frequency response of the coil generates …

010302 applied physicsPhysicsmedicine.diagnostic_testMechanical EngineeringAerospace EngineeringMagnetic resonance imaging01 natural sciencesTransfer function030218 nuclear medicine & medical imagingMagnetic fieldConductorInductanceReceiver coil03 medical and health sciences0302 clinical medicineNuclear magnetic resonanceControl flowMechanics of Materials0103 physical sciencesAutomotive EngineeringmedicineGeneral Materials ScienceJournal of Vibration and Control
researchProduct

Cyclotron instability in the afterglow mode of minimum-B ECRIS.

2016

It was shown recently that cyclotron instability in non-equilibrium plasma of a minimum-B electron cyclotron resonance ion source (ECRIS) causes perturbation of the extracted ion current and generation of strong bursts of bremsstrahlung emission, which limit the performance of the ion source. The present work is devoted to the dynamic regimes of plasma instability in ECRIS operated in pulsed mode. Instability develops in decaying plasma shortly after heating microwaves are switched off and manifests itself in the form of powerful pulses of electromagnetic emission associated with precipitation of high energy electrons. Time-resolved measurements of microwave emission bursts are presented. I…

010302 applied physicsPhysicsta114ta213Astrophysics::High Energy Astrophysical Phenomenaplasma instabilityCyclotronBremsstrahlungPlasma01 natural sciencesInstabilityIon sourceElectron cyclotron resonance010305 fluids & plasmaslaw.inventionTwo-stream instabilityPhysics::Plasma Physicslaw0103 physical scienceselectron cyclotron resonance ion sourcesAtomic physicsInstrumentationIon cyclotron resonanceThe Review of scientific instruments
researchProduct

Sub-nanosecond excitonic luminescence in ZnO:In nanocrystals

2019

The financial support of research European Union ERA.NET RUS_ST20170-51 . This work was partly supported by Russian Foundation for Basic Research, Russia , project No. 18-52-76002 . The sample preparation was carried out as part of SFERA II project -Transnational Access activities ( European Union 7th Framework Programme Grant Agreement N3126430 ).

010302 applied physicsRadiationMaterials scienceMorphology (linguistics)DopingKineticsAnalytical chemistrychemistry.chemical_elementTime-resolved luminescenceNanosecondVapour deposition01 natural sciences030218 nuclear medicine & medical imaging03 medical and health sciences0302 clinical medicineNanocrystalchemistry0103 physical sciences:NATURAL SCIENCES:Physics [Research Subject Categories]In [ZnO]Indium dopingLuminescenceInstrumentationScintillationIndium
researchProduct

Color centers in diamond as novel probes of superconductivity

2018

Magnetic imaging using color centers in diamond through both scanning and wide-field methods offers a combination of unique capabilities for studying superconductivity, for example, enabling accurate vector magnetometry at high temperature or high pressure, with spatial resolution down to the nanometer scale. The paper briefly reviews various experimental modalities in this rapidly developing nascent field and provides an outlook towards possible future directions.

010302 applied physicsSuperconductivityMaterials scienceField (physics)Condensed Matter - Mesoscale and Nanoscale PhysicsMagnetometerCondensed Matter - SuperconductivityDiamondFOS: Physical sciencesNanotechnologyengineering.materialCondensed Matter Physics01 natural sciencesElectronic Optical and Magnetic Materialslaw.inventionSuperconductivity (cond-mat.supr-con)Magnetic imaginglawHigh pressure0103 physical sciencesMesoscale and Nanoscale Physics (cond-mat.mes-hall)engineering010306 general physicsImage resolution
researchProduct

Broadband Ultrahigh-Resolution Spectroscopy of Particle-Induced X Rays: Extending the Limits of Nondestructive Analysis

2016

Nondestructive analysis (NDA) based on x-ray emission is widely used, for example, in the semiconductor and concrete industries. Here, we demonstrate significant quantitative and qualitative improvements in broadband x-ray NDA by combining particle-induced emission with detection based on superconducting microcalorimeter arrays. We show that the technique offers great promise in the elemental analysis of thin-film and bulk samples, especially in the difficult cases where tens of different elements with nearly overlapping emission lines have to be identified down to trace concentrations. We demonstrate the efficiency and resolving capabilities by spectroscopy of several complex multielement …

010302 applied physicsSuperconductivityPhysicsspectroscopyta114nondestructive analysisspektroskopiaNondestructive analysisGeneral Physics and Astronomyx-rays01 natural sciencesImaging phantomTheoretical physicsUltrahigh resolution0103 physical sciencesParticleAtomic physics010306 general physicsSpectroscopyPhysical Review Applied
researchProduct

Spectroscopic study of the electric field induced valence change of Fe-defect centers in SrTiO(3)

2011

The electrochemical changes induced by an electric field in Fe-doped SrTiO(3) have been investigated by X-ray absorption spectroscopy (XANES and EXAFS), electron paramagnetic resonance (EPR) and Raman spectroscopy. A detailed study of the Fe dopant in the regions around the anode and cathode reveals new insights into the local structure and valence state of Fe in SrTiO(3) single crystals. The ab initio full multiple-scattering XANES calculations give an evidence of the oxygen vacancy presence in the first coordination shell of iron. Differences in the length and disorder of the Fe-O bonds as extracted from EXAFS are correlated to the unequivocal identification of the defect type by compleme…

010302 applied physicsValence (chemistry)Absorption spectroscopyExtended X-ray absorption fine structureChemistryAb initioGeneral Physics and Astronomy02 engineering and technology021001 nanoscience & nanotechnology01 natural sciencesXANESlaw.inventionJsymbols.namesakeCrystallographyOxidation statelaw0103 physical sciencesddc:540symbolsPhysical and Theoretical Chemistry0210 nano-technologyElectron paramagnetic resonanceRaman spectroscopy
researchProduct

FOC with Resolver Implementation for PMSM Drives by Using a Low Cost Atmel SAM3X8E Microcontroller

2020

The aim of this paper is the low-cost experimental implementation of a field oriented control strategy for a Permanent Magnet Synchronous Motor (PMSM) by using an Atmel SAM3X8E microcontroller, mounted on an Arduino DUE board. In this electrical drive for PMSM, a resolver is used in order to measure the rotor position and speed: Therefore, the low-cost Arduino DUE performs not only FOC algorithm and phase currents data acquisition, but also a resolver-To-digital converter process, rotor position and speed data acquisition, and resolver signals management. The code has been implemented in the open source Arduino IDE, using C language, whereas the control and plot visualization interfaces hav…

010302 applied physicsVector controlField oriented Control (FOC)Rotor (electric)business.industryComputer science020208 electrical & electronic engineeringProcess (computing)02 engineering and technologySettore ING-IND/32 - Convertitori Macchine E Azionamenti Elettrici01 natural sciencesElectrical driveslaw.inventionMicrocontrollerPrinted circuit boardData acquisitionmicrocontrollerlawArduinoResolver0103 physical sciences0202 electrical engineering electronic engineering information engineeringPermanent magnet synchronous motor (PMSM)businessComputer hardware2020 Fifteenth International Conference on Ecological Vehicles and Renewable Energies (EVER)
researchProduct

High sensitivity characterization of the nonlinear electric susceptibility of a glass ceramic in the microwave range

2019

The nonlinear electric susceptibility of a glass ceramic is characterized in the microwave range by measuring intermodulation of two high-power signals. To achieve the necessary sensitivity for dielectric nonlinearities, the setup ensures that the measured intermodulation can be ascribed to the material under test while all other intermodulation sources are suppressed. This is achieved by coupling three dielectric resonators in a cut-off waveguide. The third order nonlinearity of the glass ceramic is found to be χ3/er = (1.6 ± 0.8) × 10−15 m2/V2 at 950 MHz. The magnitude is comparable to the previously measured high-end sintered ceramics. The power of the intermodulation signal as a functio…

010302 applied physicsWaveguide (electromagnetism)Materials scienceGlass-ceramicPhysics and Astronomy (miscellaneous)business.industryElectric susceptibility02 engineering and technologyDielectric021001 nanoscience & nanotechnology01 natural scienceslaw.inventionResonatorlawvisual_art0103 physical sciencesvisual_art.visual_art_mediumOptoelectronicsCeramic0210 nano-technologybusinessSensitivity (electronics)IntermodulationApplied Physics Letters
researchProduct