Search results for "Resolution"
showing 10 items of 1928 documents
Laser spectroscopy — Recent results and prospects for lighter nuclei
1992
Atomic physics methods have provided important information about the electromagnetic properties of the nuclear ground states. In recent years the experimental effort has been directed towards optical high resolution spectroscopy of very high sensitivity, giving access to short-lived nuclides very far from stability. A few of these new techniques based on collinear laser spectroscopy are presented with their latest results. They are suitable for an extension of the experiments to the region of lighter nuclei.
High Resolution Λ Hypernuclear Spectroscopy with Electron Beams
2015
T. Gogami1 ∗, P. Achenbach2, A. Ahmidouch3, I. Albayrak4, D. Androic5, A. Asaturyan6, R. Asaturyan6, O. Ates4, P. Baturin7, R. Badui7, W. Boeglin7, J. Bono7, E. Brash8, P. Carter8, C. Chen4, A. Chiba1, E. Christy4, S. Danagoulian3, R. De Leo10, D. Doi1, M. Elaasar11, R. Ent9, Y. Fujii1, M. Fujita1, M. Furic5, M. Gabrielyan7, L. Gan12, F. Garibaldi13, D. Gaskell9, A. Gasparian3, O. Hashimoto1, T. Horn9, B. Hu14, Ed. V. Hungerford21, M. Jones9, H. Kanda1, M. Kaneta1, S. Kato19, M. Kawai1, D. Kawama1, H. Khanal7, M. Kohl4, A. Liyanage4, W. Luo14, K. Maeda1, A. Margaryan6, P. Markowitz7, T. Maruta1, A. Matsumura1, V. Maxwell7, A. Mkrtchyan6, H. Mkrtchyan6, S. Nagao1, S. N. Nakamura1, A. Narayan…
Design, construction and performance of the energy compressing system of the Mainz 300 MeV electron linac
1973
Abstract For the sake of better energy resolution of the 300 MeV electron linac of Mainz university a system has been built which transforms a sharply bunched beam of poor energy resolution into a beam of sharply defined energy, while its bunches are smeared out. The system is described, its design philosophy and some essential construction details are given. The operating experience of the last 6 months since completion of the system is communicated.
Messungen am Po214 γ-Spektrum mit einem Ge(Li)-Paar-Spektrometer
1969
Theγ-ray spectrum of Po214 between energies of 1.1 and 3.3 MeV was measured with a resolution of 4–5 keV. The energies and intensities of 69γ-rays are tabulated and an improved level scheme of the Bi214-Po214 decay is proposed.
Design of a second generation RFQ Ion Cooler and Buncher (RFQCB) for ISOLDE
2004
As a part of the ISOLDE Consolidation project, a new beam-cooling device will be incorporated into the High Resolution Separator (HRS) to improve the ion beam delivered to the experiments. The whole beam line at this point needs to be redesigned to accommodate the ion cooler and provide beam-matching. In this paper the status of the mechanical design, the optical design and the vacuum system of the device are presented.
High-resolution γ-ray spectroscopy: a versatile tool for nuclear β-decay studies at TRIUMF-ISAC
2005
High-resolution γ-ray spectroscopy is essential to fully exploit the unique, high-quality beams available at the next generation of radioactive ion beam facilities such as the TRIUMF isotope separator and accelerator (ISAC). The 8π spectrometer, which consists of 20 Compton-suppressed HPGe detectors, has recently been reconfigured for a vigorous research programme in weak interaction and nuclear structure physics. With the addition of a variety of ancillary detectors it has become the world's most powerful device dedicated to β-decay studies. This paper provides a brief overview of the apparatus and highlights from recent experiments.
Hypernuclear Spectroscopy at JLab Hall C
2010
Abstract Since the 1st generation experiment, E89-009, which was successfully carried out as a pilot experiment of (e,e'K+) hypernuclear spectroscopy at JLab Hall C in 2000, precision hypernuclear spectroscopy by the (e,e'K+) reactions made considerable progress. It has evolved to the 2nd generation experiment, E01-011, in which a newly constructed high resolution kaon spectrometer (HKS) was installed and the “Tilt method” was adopted in order to suppress large electromagnetic background and to run with high luminosity. Preliminary high-resolution spectra of 7 Λ He and 28 Λ Al together with that of 12 Λ B that achieved resolution better than 500 keV(FWHM) were obtained. The third generation…
Measurement of the mass and width of the charmed meson D∗+ (2010)
1992
Abstract Using a high-resolution silicon vertex detector we have observed a very clean signal of 127 D∗+. After a careful study of the experimental resolution of our apparatus we have measured m( D ∗++ )−m( D 0 ) = 145.39±0.06±0.03 MeV . We have also obtained a 90% CL upper limit to γ(D∗+) of 131 keV.
Probing hypernuclei at $$ \bar P $$ anda and at MAMI-C
2008
Spectroscopy of Λ hypernuclei has recently become one of the most valuable tools for the experimental investigation of strangeness nuclear physics. Several new approached are being pursued currently: In Mainz, the Microtron MAMI has been upgraded to 1.5 GeV electron beam energy and will be used to produce strange hadronic systems in the near future. The KaoS spectrometer is being installed for large acceptance, high resolution strangeness reaction spectroscopy at the existing spectrometer facility. The Mainz hypernuclei research programme will be complemented by experiments on multi-strange systems at the planned FAIR facility at GSI. The γ-ray spectroscopy of double Λ hypernuclei produced …
Ultra-high resolution mass separator—Application to detection of nuclear weapons tests
2009
Abstract A Penning trap-based purification process having a resolution of about 1 ppm is reported. In this context, we present for the first time a production method for the most complicated and crucially important nuclear weapons test signature, 133mXe. These pure xenon samples are required by the Comprehensive Nuclear-Test-Ban Treaty Organization to standardize and calibrate the worldwide network of xenon detectors.