Search results for "Resolution"

showing 10 items of 1928 documents

Review of thermal infrared applications and requirements for future high-resolution sensors

2016

High-resolution thermal infrared (TIR) remote sensing has a wide range of applications. In this paper, we describe the different applications and requirements identified in a literature review and during a consultation meeting with researcher experts in different fields. As a result, more than 30 applications were identified within three different fields: 1) land and solid Earth; 2) health and hazards; and 3) security and surveillance. A complete set of requirements (spatial, temporal, and radiometric resolution, algorithms used, and supporting data, among others) for each application is also provided. The results presented in this paper provide useful information to enhance the importance …

Thermal infrared010504 meteorology & atmospheric sciencesComputer scienceFuegosathigh resolution0211 other engineering and technologiesHigh resolutionland surface temperatureSettore ING-INF/02 - Campi Elettromagnetici02 engineering and technology01 natural sciencesSet (abstract data type)Fuegosat; high resolution; land surface emissivity; land surface temperature; thermal infraredland surface emissivitySystems engineeringGeneral Earth and Planetary Sciencesthermal infraredElectrical and Electronic EngineeringSolid earth021101 geological & geomatics engineering0105 earth and related environmental sciencesRemote sensing
researchProduct

Minimum configuration of thermal infrared bands for land surface temperature and emissivity estimation in the context of potential future missions

2014

Abstract A number of applications rely on the availability of high resolution TIR data, both in terms of spatial and temporal resolution, as well as in terms of spectral configuration. A consensus exists among the thermal community regarding the lack of such a kind of data, since only one operational sensor is currently providing multispectral TIR data at high spatial resolution (the case of ASTER, at 90 m spatial resolution and a 16-day revisit time). In this paper we propose a minimum multispectral configuration to allow the retrieval of both land surface temperature (LST) and emissivity ( e ) from thermal infra-red (TIR) data. For this purpose, we propose a minimum configuration based on…

Thermal infraredLand surface temperatureComputer scienceTemporal resolutionMultispectral imageThermalEmissivityHigh spatial resolutionSoil ScienceGeologyComputers in Earth SciencesImage resolutionRemote sensingRemote Sensing of Environment
researchProduct

Land Surface Temperature Retrieval Methods From Landsat-8 Thermal Infrared Sensor Data

2014

The importance of land surface temperature (LST) retrieved from high to medium spatial resolution remote sensing data for many environmental studies, particularly the applications related to water resources management over agricultural sites, was a key factor for the final decision of including a thermal infrared (TIR) instrument on board the Landsat Data Continuity Mission or Landsat-8. This new TIR sensor (TIRS) includes two TIR bands in the atmospheric window between 10 and 12 $\mu\hbox{m}$ , thus allowing the application of split-window (SW) algorithms in addition to single-channel (SC) algorithms or direct inversions of the radiative transfer equation used in previous sensors on board …

Thermal infraredLand surface temperatureMeteorologyInfrared windowRadiative transferEmissivityEnvironmental scienceAtmospheric modelElectrical and Electronic EngineeringGeotechnical Engineering and Engineering GeologyImage resolutionSpectral lineRemote sensingIEEE Geoscience and Remote Sensing Letters
researchProduct

Fullerene-ionic-liquid conjugates: a new class of hybrid materials with unprecedented properties.

2015

A modular approach has been followed for the synthesis of a series of fullerene-ionic-liquid (IL) hybrids in which the number of IL moieties (two or twelve), anion, and cation have been varied. The combination of C60 and IL give rise to new unique properties in the conjugates such as solubility in water, which was higher than 800 mg mL(-1) in several cases. In addition, one of the C60 -IL hybrids has been employed for the immobilization of palladium nanoparticles through ion exchange followed by reduction with sodium borohydride. Surprisingly, during the reduction several carbon nanostructures were formed that comprised nano-onions and nanocages with few-layer graphene sidewalls, which have…

Thermogravimetric analysisGraphenefullereneOrganic Chemistryhybrid materialGeneral ChemistrySettore CHIM/06 - Chimica OrganicaCatalysislaw.inventionchemistry.chemical_compoundSodium borohydrideNanocageschemistryX-ray photoelectron spectroscopylawIonic liquidnanostructuresOrganic chemistryC-C couplingHybrid materialHigh-resolution transmission electron microscopyNuclear chemistryionic liquidChemistry (Weinheim an der Bergstrasse, Germany)
researchProduct

Fluctuation Methods To Study Protein Aggregation in Live Cells: Concanavalin A Oligomers Formation

2011

Prefibrillar oligomers of proteins are suspected to be the primary pathogenic agents in several neurodegenerative diseases. A key approach for elucidating the pathogenic mechanisms is to probe the existence of oligomers directly in living cells. In this work, we were able to monitor the process of aggregation of Concanavalin A in live cells. We used number and brightness analysis, two-color cross number and brightness analysis, and Raster image correlation spectroscopy to obtain the number of molecules, aggregation state, and diffusion coefficient as a function of time and cell location. We observed that binding of Concanavalin A to the membrane and the formation of small aggregates paralle…

Time FactorsCell SurvivalCellSpectroscopy Imaging and Other TechniquesBiophysicsProtein aggregationCell morphologyCell membraneDiffusion03 medical and health scienceschemistry.chemical_compoundMice0302 clinical medicineProtein structure2-NaphthylaminemedicineConcanavalin AAnimalsconfocal microscopy super resolution protein aggregation kinetics in live cells amyloid related pathologiesAnnexin A5Protein Structure QuaternaryCell Shape030304 developmental biology0303 health sciencesbiologySpectrum AnalysisCell MembraneFibroblastsEmbryo MammalianCell biologyMembranemedicine.anatomical_structurechemistryConcanavalin Abiology.proteinLaurdan030217 neurology & neurosurgeryFluorescein-5-isothiocyanateLaurates
researchProduct

Classification of Pecorino cheeses produced in Italy according to their ripening time and manufacturing technique using Fourier transform infrared sp…

2010

Fourier-transform infrared spectroscopy, followed by linear discriminant analysis of the spectral data, was used to classify Italian Pecorino cheeses according to their ripening time and manufacturing technique. The Fourier transform infrared spectra of the cheeses were divided into 18 regions and the normalized absorbance peak areas within these regions were used as predictors. Linear discriminant analysis models were constructed to classify Pecorino cheeses according to different ripening stages (hard and semi-hard) or according to their manufacturing technique (fossa and nonfossa cheeses). An excellent resolution was achieved according to both ripening time and manufacturing technique. A…

Time FactorsRIPENINGFood HandlingAnalytical chemistryInfrared spectroscopyCheese ripeningsymbols.namesakeCheeseSpectroscopy Fourier Transform InfraredGeneticsFourier transform infrared spectroscopyMathematicsFOURIER TRANSFORM INFRARED SPECTROSCOPYbusiness.industryResolution (electron density)Discriminant AnalysisPattern recognitionRipeningLinear discriminant analysisFourier transform infrared spectraFourier transformLINEAR DISCRIMINANT ANALYSISItalyPECORINO CHEESEsymbolsFood TechnologyAnimal Science and ZoologyArtificial intelligencebusinessFood ScienceJournal of Dairy Science
researchProduct

Comparison of basis functions for 3D PET reconstruction using a Monte Carlo system matrix.

2012

In emission tomography, iterative statistical methods are accepted as the reconstruction algorithms that achieve the best image quality. The accuracy of these methods relies partly on the quality of the system response matrix (SRM) that characterizes the scanner. The more physical phenomena included in the SRM, the higher the SRM quality, and therefore higher image quality is obtained from the reconstruction process. High-resolution small animal scanners contain as many as 103?104 small crystal pairs, while the field of view (FOV) is divided into hundreds of thousands of small voxels. These two characteristics have a significant impact on the number of elements to be calculated in the SRM. …

Time FactorsRadiological and Ultrasound TechnologyRotationStatistical noisebusiness.industryImage qualityPhantoms ImagingMonte Carlo methodBasis functioncomputer.software_genreNoiseImaging Three-DimensionalVoxelPositron-Emission TomographyRadiology Nuclear Medicine and imagingComputer visionArtificial intelligencebusinesscomputerAlgorithmImage resolutionMonte Carlo MethodSmoothingMathematicsPhysics in medicine and biology
researchProduct

Global retention models and their application to the prediction of chromatographic fingerprints

2020

Abstract The resolution of samples containing unknown compounds of different nature, or without standards available, as is the case of chromatographic fingerprints, is still a challenge. Possibly, the most problematic aspect that prevents systematic method development is finding models that describe without bias the retention behaviour of the compounds in the samples. In this work, the use of global models (able to describe the whole sample) is proposed as an alternative to the use of individual models for each solute. Global models contain parameters that are specific for each solute, while other parameters ‒related to the column and solvent‒ are common for all solutes. A special regressio…

Time FactorsResolution (mass spectrometry)Predictive capability010402 general chemistry01 natural sciencesBiochemistryHigh-performance liquid chromatographyAnalytical ChemistryComputer SimulationChromatographySulfonamidesChromatographyPlant ExtractsChemistryElution010401 analytical chemistryOrganic ChemistryChamomileWaterGeneral MedicineModels TheoreticalReference StandardsMethod development0104 chemical sciencesRegression AnalysisGradient elutionAlgorithmsJournal of Chromatography A
researchProduct

Influence of respiratory rate and end-expiratory pressure variation on cyclic alveolar recruitment in an experimental lung injury model

2012

Introduction Cyclic alveolar recruitment/derecruitment (R/D) is an important mechanism of ventilator-associated lung injury. In experimental models this process can be measured with high temporal resolution by detection of respiratory-dependent oscillations of the paO2 (ΔpaO2). A previous study showed that end-expiratory collapse can be prevented by an increased respiratory rate in saline-lavaged rabbits. The current study compares the effects of increased positive end-expiratory pressure (PEEP) versus an individually titrated respiratory rate (RRind) on intra-tidal amplitude of Δ paO2 and on average paO2 in saline-lavaged pigs. Methods Acute lung injury was induced by bronchoalveolar lavag…

Time FactorsRespiratory rateSwinePilot ProjectsLung injuryCritical Care and Intensive Care MedicinePositive-Pressure RespirationRandom AllocationRespiratory Ratevarying shunt fractionsAnimalsMedicineddc:610porcine modelcyclic alveolar recruitmentbusiness.industryResearchLung Injuryrespiratory systemrespiratory- dependent paO 2 oscillationsrespiratory tract diseasesPulmonary AlveoliDisease Models Animalacute lung injuryAnesthesiaHigh temporal resolutionIncreased respiratory ratebusinesscirculatory and respiratory physiologyCritical Care
researchProduct

Protein dynamics observed by tunable mid-IR quantum cascade lasers across the time range from 10 ns to 1 s

2017

We have developed a spectrometer based on tunable quantum cascade lasers (QCLs) for recording time-resolved absorption spectra of proteins in the mid-infrared range. We illustrate its performance by recording time-resolved difference spectra of bacteriorhodopsin in the carboxylic range (1800–1700 cm− 1) and on the CO rebinding reaction of myoglobin (1960–1840 cm− 1), at a spectral resolution of 1 cm− 1. The spectrometric setup covers the time range from 4 ns to nearly a second with a response time of 10–15 ns. Absorption changes as low as 1 × 10− 4 are detected in single-shot experiments at t > 1 μs, and of 5 × 10− 6 in kinetics obtained after averaging 100 shots. While previous time-res…

Time FactorsSpectrophotometry InfraredAbsorption spectroscopyAnalytical chemistry010402 general chemistry53001 natural sciencesMolecular physicsSpectral lineAnalytical Chemistrylaw.inventionchannelrhodopsinflash photolysislawSpectral resolutionAbsorption (electromagnetic radiation)InstrumentationSpectroscopyCarbon MonoxidebiologySpectrometerChemistrybacteriorhodopsinLasers010401 analytical chemistry500 Naturwissenschaften und Mathematik::530 Physik::530 PhysikWaterBacteriorhodopsinLasertime-resolved IR spectroscopyAtomic and Molecular Physics and Optics0104 chemical sciencesSolutionsKineticsCascadeBacteriorhodopsinsmyoglobinbiology.proteinQuantum Theory
researchProduct