Search results for "Resolution"

showing 10 items of 1928 documents

Comparison of MODIS and Landsat-8 retrievals of Chlorophyll-a and water temperature over Lake Titicaca

2016

Chlorophyll-a concentration ([Chl-a]) and Lake Surface Temperature (LST) were retrieved in Lake Titicaca (Peru-Bolivia) using MODIS and Landsat-8 images. The lake was chosen as a case-study for evaluating the feasibility of Landsat-8 images for [Chl-a] and LST monitoring in oligotrophic and mesotrophic water bodies. The big size of the lake and its spatial and temporal variability, allowed the comparison of MODIS and Landsat-8 products for a wide range of [Chl-a] and LST. The atmospheric correction of the images was facilitated by the very high altitude of the lake. MODIS images were processed with standard ocean color algorithms whereas for Landsat-8, specific algorithms were tested and va…

Chlorophyll aWatershed010504 meteorology & atmospheric sciences0211 other engineering and technologiesAtmospheric correctionClimate change02 engineering and technology01 natural sciencesSea surface temperaturechemistry.chemical_compoundchemistryOcean colorEnvironmental scienceEutrophicationImage resolution021101 geological & geomatics engineering0105 earth and related environmental sciencesRemote sensing2016 IEEE International Geoscience and Remote Sensing Symposium (IGARSS)
researchProduct

Towards the quantitative and physically-based interpretation of solar-induced vegetation fluorescence retrieved from global imaging

2021

Due to emerging high spectral resolution, remote sensing techniques and ongoing developments to retrieve the spectrally resolved vegetation fluorescence spectrum from several scales, the light reactions of photosynthesis are receiving a boost of attention for the monitoring of the Earth's carbon balance. Sensor-retrieved vegetation fluorescence (from leaf, tower, airborne or satellite scale) originating from the excited antenna chlorophyll a molecule has become a new quantitative biophysical vegetation parameter retrievable from space using global imaging techniques. However, to retrieve the actual quantum efficiencies, and hence a true photosynthetic status of the observed vegetation, all …

Chlorophyll aquantitative remote sensingPhysiologyEnergy transferBotanyPlant Sciencephotosynthesis monitoringReflectivityFluorescencechemistry.chemical_compoundchemistryQK1-989fluorescence quantum efficiencymedicineEnvironmental scienceflex-sentinel-3 tandem missionSatelliteSpectral resolutionmedicine.symptomScale (map)Vegetation (pathology)Remote sensingPhotosynthetica
researchProduct

Multitemporal Monitoring of Plant Area Index in the Valencia Rice District with PocketLAI

2016

Leaf area index (LAI) is a key biophysical parameter used to determine foliage cover and crop growth in environmental studies in order to assess crop yield. Frequently, plant canopy analyzers (LAI-2000) and digital cameras for hemispherical photography (DHP) are used for indirect effective plant area index (PAI(eff)) estimates. Nevertheless, these instruments are expensive and have the disadvantages of low portability and maintenance. Recently, a smartphone app called PocketLAI was presented and tested for acquiring PAI(eff) measurements. It was used during an entire rice season for indirect PAI(eff) estimations and for deriving reference high-resolution PAI(eff) maps. Ground PAI(eff) value…

Chlorophyll contenteffective plant area index (PAI(eff))010504 meteorology & atmospheric sciencesHemispherical photographyeffective plant area index (PAIeff)Science0211 other engineering and technologiesPocketLAIPlant area index02 engineering and technologyrice; effective plant area index (PAI<sub><i>eff</i></sub>); PocketLAI; smartphone; high-resolution mapsmartphonehigh-resolution map01 natural sciencesparasitic diseasesLeaf area index021101 geological & geomatics engineering0105 earth and related environmental sciencesRemote sensing2. Zero hungerPhenologyCrop yieldriceQCiències de la terrafood and beverages15. Life on landSmartphone appGeneral Earth and Planetary SciencesEnvironmental scienceSatelliteRemote Sensing
researchProduct

Evaluation of Sentinel-2 Red-Edge Bands for Empirical Estimation of Green LAI and Chlorophyll Content

2011

ESA’s upcoming satellite Sentinel-2 will provide Earth images of high spatial, spectral and temporal resolution and aims to ensure continuity for Landsat and SPOT observations. In comparison to the latter sensors, Sentinel-2 incorporates three new spectral bands in the red-edge region, which are centered at 705, 740 and 783 nm. This study addresses the importance of these new bands for the retrieval and monitoring of two important biophysical parameters: green leaf area index (LAI) and chlorophyll content (Ch). With data from several ESA field campaigns over agricultural sites (SPARC, AgriSAR, CEFLES2) we have evaluated the efficacy of two empirical methods that specifically make use of the…

ChlorophyllChlorophyll contentMean squared errorRed edgelcsh:Chemical technologyBiochemistrySentinel-2; chlorophyll; LAI; NAOC; NDI; red-edgeGreen leafArticleNDIAnalytical Chemistryred-edgelcsh:TP1-1185Electrical and Electronic EngineeringSpacecraftInstrumentationRemote sensingNAOCHyperspectral imagingSpectral bandsReflectivityAtomic and Molecular Physics and OpticsLAIPlant LeavesSpectrophotometryTemporal resolutionEnvironmental scienceSentinel-2Sensors (Basel, Switzerland)
researchProduct

Sun-induced fluorescence - a new probe of photosynthesis: First maps from the imaging spectrometer HyPlant.

2015

Variations in photosynthesis still cause substantial uncertainties in predicting photosynthetic CO2 uptake rates and monitoring plant stress. Changes in actual photosynthesis that are not related to greenness of vegetation are difficult to measure by reflectance based optical remote sensing techniques. Several activities are underway to evaluate the sun-induced fluorescence signal on the ground and on a coarse spatial scale using space-borne imaging spectrometers. Intermediate-scale observations using airborne-based imaging spectroscopy, which are critical to bridge the existing gap between small-scale field studies and global observations, are still insufficient. Here we present the first …

Chlorophyllinduced fluorescencesunImaging spectrometer2306 Global and Planetary ChangeFluorescence2300 General Environmental SciencePhotosynthesiEnvironmental ChemistryAirborne measurement910 Geography & travelSpectral resolutionPhotosynthesisAbsorption (electromagnetic radiation)Spectroscopyairborne measurementsChlorophyll fluorescenceGeneral Environmental ScienceRemote sensingGlobal and Planetary ChangeSpectrometerEcology2300Remote sensingImaging spectroscopyVegetation monitoringFLEXImaging spectroscopy10122 Institute of GeographyGEO/10 - GEOFISICA DELLA TERRA SOLIDASpectrometry FluorescenceSun-induced fluorescence2304 Environmental ChemistryHyPlantRemote Sensing TechnologySunlightEnvironmental scienceSpatial variabilityChlorophyll fluorescence2303 EcologyGlobal change biology
researchProduct

Determination of 2,3,7,8-tetrachlorodibenzo-p-dioxin in goat milk and tissues by glass capillary gas chromatography and medium resolution mass fragme…

1981

Abstract An analytical method has been developed for the study of the elimination of 2,3,7,8-tetrachlodoribenzo-p-dioxin (TCDD) by lactation and its determination in various tissues of goat. The method is based on the alkaline hydrolysis of milk, liver, fat, muscle, blood, faeces and urine samples, extraction with n-hexane, treatment with sulphuric acid-saturated silica gel, chromatographic clean-up on silica gel and alumina micro-columns, and glass capillary gas chromatography—medium resolution mass fragmenography (resolution 2000). 1,2,3,4-Tetrachlorodibenzo-p-dioxin is used as the internal standard, the concentration of TCDD being determined from the calibration curve calculated from the…

Chromatography GasPolychlorinated DibenzodioxinsResolution (mass spectrometry)Calibration curveUrine010501 environmental sciencesDioxins01 natural sciencesBiochemistryGas Chromatography-Mass SpectrometryAnalytical Chemistrychemistry.chemical_compoundLactationmedicineAnimalsTissue Distributionheterocyclic compounds0105 earth and related environmental sciencesDetection limitReproducibilityChromatographySilica gelGoatsMuscles010401 analytical chemistryOrganic ChemistryExtraction (chemistry)General Medicine0104 chemical sciencesMilkmedicine.anatomical_structureLiverchemistryJournal of Chromatography A
researchProduct

Approaches to characterise chromatographic column performance based on global parameters accounting for peak broadening and skewness.

2009

Peak broadening and skewness are fundamental parameters in chromatography, since they affect the resolution capability of a chromatographic column. A common practice to characterise chromatographic columns is to estimate the efficiency and asymmetry factor for the peaks of one or more solutes eluted at selected experimental conditions. This has the drawback that the extra-column contributions to the peak variance and skewness make the peak shape parameters depend on the retention time. We propose and discuss here the use of several approaches that allow the estimation of global parameters (non-dependent on the retention time) to describe the column performance. The global parameters arise f…

Chromatography Reverse-PhaseChromatographyAcetonitrilesResolution (mass spectrometry)ChemistryElutionOrganic ChemistryAdrenergic beta-AntagonistsLinear modelNormal DistributionGeneral MedicineReversed-phase chromatographyBiochemistryColumn (database)Standard deviationAnalytical ChemistryNormal distributionModels ChemicalSkewnessBenzene DerivativesLinear ModelsDiureticsJournal of chromatography. A
researchProduct

Finding the best separation in situations of extremely low chromatographic resolution.

2010

Abstract Samples with a large number of compounds or similarities in their structure and polarity may yield insufficient chromatographic resolution. In such cases, however, finding conditions where the largest number of compounds appears sufficiently resolved can be still worthwhile. A strategy is here reported that optimises the resolution level of chromatograms in cases where conventional global criteria, such as the worst resolved peak pair or the product of elementary resolutions, are not able to detect any separation, even when most peaks are baseline resolved. The strategy applies a function based on the number of “well resolved” peaks, which are those that exceed a given threshold of…

Chromatography Reverse-PhaseChromatographyAcetonitrilesResolution (mass spectrometry)ChemistryLow resolutionOrganic ChemistrySeparation (aeronautics)Analytical chemistryGeneral MedicineFunction (mathematics)Partial resolutionHydrogen-Ion ConcentrationBiochemistryAnalytical ChemistryChromatographic separationModels ChemicalYield (chemistry)Organic ChemicalsJournal of chromatography. A
researchProduct

1-Hexyl-3-methyl imidazolium tetrafluoroborate: an efficient column enhancer for the separation of basic drugs by reversed-phase liquid chromatograph…

2012

Abstract Ionic liquids are dual modifiers composed by a large anion and a large cation, which interact with both the hydrophobic alkyl-bonded phase and the anionic residual silanols in C18 columns. The deactivation of the silanol groups has important implications on the chromatographic analysis of basic drugs, being the improvement of peak profiles and shorter retention times the most noticeable features. However, other characteristics as selectivity or resolution are not usually considered, or are only examined for selected chromatographic conditions. In this work, the effect of the addition of the ionic liquid 1-hexyl-3-methyl imidazolium tetrafluoroborate to acetonitrile–water mixtures i…

Chromatography Reverse-PhaseChromatographyResolution (mass spectrometry)ChemistryOrganic ChemistryImidazolesGeneral MedicineReversed-phase chromatographyHydrogen-Ion ConcentrationBiochemistryAnalytical ChemistryIonchemistry.chemical_compoundSilanolPharmaceutical PreparationsPhase (matter)Ionic liquidBoratesSelectivityAcetonitrileJournal of chromatography. A
researchProduct

A complementary mobile phase approach based on the peak count concept oriented to the full resolution of complex mixtures

2011

Situations of minimal resolution are often found in liquid chromatography, when samples that contain a large number of compounds, or highly similar in terms of structure and/or polarity, are analysed. This makes full resolution with a single separation condition (e.g., mobile phase, gradient or column) unfeasible. In this work, the optimisation of the resolution of such samples in reversed-phase liquid chromatography is approached using two or more isocratic mobile phases with a complementary resolution behaviour (complementary mobile phases, CMPs). Each mobile phase is dedicated to the separation of a group of compounds. The CMPs are selected in such a way that, when the separation is cons…

Chromatography Reverse-PhaseChromatographyResolution (mass spectrometry)business.industryChemistryComputationSample (material)Organic ChemistryPhase (waves)General MedicineComplex MixturesBiochemistryColumn (database)Analytical ChemistryGenetic algorithmLocal search (optimization)businessLinear searchJournal of Chromatography A
researchProduct