Search results for "Response"

showing 10 items of 4136 documents

18F-FDG PET imaging of breast cancer : evaluation of the metabolic behaviour of the different breast cancer subtypes and prediction of the tumor resp…

2015

Positron Emission Tomography (PET) with 18Fluoro-deoxyglucose (18F-FDG) is the reference imaging examination for in-vivo quantification of the glucidic metabolism of tumour cells. It allows for the monitoring of tumour metabolic changes during chemotherapy. Breast cancer comprises several distinct genomic entities with different biological characteristics and clinical behaviours, leading to different tailored treatments. The aim of this doctoral thesis was to evaluate the relationship between the different biological entities of breast cancer and the tumour metabolic behaviour during neoadjuvant chemotherapy. We have also retrieved, among the various metabolic parameters on PET images, the …

Subtypes[SDV.IB] Life Sciences [q-bio]/BioengineeringFDGPositon EmissionTomographyRéponse tumoraleNeoadjuvant chemotherapyPhénotypesPETBreast cancerTEP[SDV.CAN] Life Sciences [q-bio]/CancerÉvaluationTomographie par Emission de PositonChimiothérapie néoadjucanteTumor responseCancer du sein[SPI.SIGNAL] Engineering Sciences [physics]/Signal and Image processing
researchProduct

Capture of extracellular zinc ions by astrocytes.

2006

Synaptic zinc ions released during synaptic transmission interact with pre- and postsynaptic neuroreceptors, thus modulating neurotransmission. It is likely that they have to be efficiently cleared from the extracellular milieu to assure subsequent synaptic events. Both neurons and glia are assumed to participate in this clearance by mechanisms that are not fully understood. In this study, electron microscopic zinc cytochemistry has shown zinc-electrondense particles associated with hippocampal astrocytic membranes frequently found accumulated in stacked lamellae. In cultured astrocytes, the use of zinc fluorochromes and endocytic markers allowed the simultaneous imaging of the capture of e…

SucroseEndosomeEndocytic cyclechemistry.chemical_elementZincEndosomesNeurotransmissionBiologyCellular and Molecular NeuroscienceGlial Fibrillary Acidic ProteinmedicineExtracellularAnimalsHomeostasisCells CulturedOrganellesDose-Response Relationship DrugImmunohistochemistryMicroscopy ElectronZincmedicine.anatomical_structureNeurologychemistryAstrocytesBiophysicsCytochemistryNeurogliaRabbitsExtracellular SpaceNeuroscienceAstrocyteGlia
researchProduct

Freezing without surrounding cryomedium preserves the endothelium and its function in human internal mammary arteries

2005

Abstract Purpose Cryopreserved human blood vessels may become important tools in bypass surgery. Optimal cryopreservation of an arterial graft should, therefore, preserve both histological and physiological characteristics of smooth muscle and endothelium comparable to the unfrozen artery. Methods Rings from human internal mammary arteries (IMA) were investigated in vitro either unfrozen or after immersion into a cryomedium (RPMI 1640 containing 1.8 M Me2SO and 0.1 M sucrose) and cryostorage with and without surrounding medium. Results In unfrozen IMA, neither contractile responses to noradrenaline (NA) nor endothelium-dependent relaxant responses to acetylcholine (ACH) was modified after e…

SucrosePathologymedicine.medical_specialtyEndotheliumBiologyGeneral Biochemistry Genetics and Molecular BiologyCryopreservationAndrologyNorepinephrinechemistry.chemical_compoundCryoprotective AgentsFreezingmedicineHumansDimethyl SulfoxideEndotheliumMammary ArteriesPhorbol 1213-DibutyrateProtein Kinase CProtein kinase CCryopreservationDose-Response Relationship DrugDimethyl sulfoxideTemperatureMuscle SmoothGeneral MedicineAcetylcholineCulture MediaCold TemperatureEnzyme ActivationMicroscopy ElectronDose–response relationshipmedicine.anatomical_structurechemistryCarcinogensMicroscopy Electron ScanningMammary arteryEndothelium VascularTissue PreservationGeneral Agricultural and Biological SciencesAcetylcholinemedicine.drugArteryCryobiology
researchProduct

A fuel cell-supercapacitor power supply for portable applications

2008

Due to the increasing number and complexity of the available functions, modern handheld devices require higher and higher current slew rates. Customers' requirements lead to a growing interest in longer-lasting power, fast transient response power supply systems and minimization of system weight, volume and cost. Fuel cell based hybrid systems are designed to meet all requirements. In this paper, a fuel cell-supercapacitor hybrid power supply for portable applications is proposed. The power management subsystem is designed and simulation results are shown to test the efficiency of the control algorithm. ©2008 IEEE.

SupercapacitorPower managementEngineeringbusiness.industryFuel cellElectrical engineeringSettore ING-IND/32 - Convertitori Macchine E Azionamenti ElettriciInductorSettore ING-INF/01 - ElettronicaAutomotive engineeringPower (physics)Hybrid systemTransient responseHybrid powerSwitched-mode power supply applicationsbusiness2008 11th Workshop on Control and Modeling for Power Electronics
researchProduct

Microwave response of a cylindrical cavity made of bulk MgB2 superconductor

2008

We report on the microwave properties of a resonant cylindrical cavity made of bulk MgB2 superconductor, produced by the reactive liquid Mg infiltration process. The frequency response of the cavity has been measured in the range 5-13GHz. Among the various modes, the TE011, resonating at 9.79GHz, exhibits the highest quality factor. For this mode, we have determined the temperature dependence of the quality factor, obtaining values of the order of 10^5 in the temperature range 4.2-30K. The values of the surface resistance deduced from the measurements of the quality factor agree quite well with those independently measured in a small sample of MgB2 extracted from the same specimen from whic…

SuperconductivityFrequency responseMaterials scienceCondensed matter physicsMgB2Condensed Matter - SuperconductivitySettore FIS/01 - Fisica SperimentaleFOS: Physical sciencesEnergy Engineering and Power TechnologyAtmospheric temperature rangeCondensed Matter PhysicsElectronic Optical and Magnetic MaterialsSuperconducting microwave cavitySuperconductivity (cond-mat.supr-con)Surface conductivityQuality (physics)Surface resistanceElectrical and Electronic EngineeringSheet resistanceMicrowaveMicrowave cavity
researchProduct

Microwave Response of Coaxial Cavities Made of Bulk Magnesium Diboride

2014

We report on the microwave (mw) properties of coaxial cavities built by using bulk MgB2 superconductor prepared by reactive liquid Mg infiltration technology. We have assembled a homogeneous cavity, by using an outer MgB2 cylinder and an inner MgB2 rod, and a hybrid cavity by using an outer copper cylinder and the same MgB2 rod as inner conductor. By the analysis of the resonance curves, in the different resonant modes, we have determined the microwave surface resistance, Rs, of the MgB2 materials as a function of the temperature and the frequency, in the absence of DC magnetic fields. At T = 4.2 K and f = 2.5 GHz, by a mw pulsed technique, we have determined the quality factor of the homog…

SuperconductivityMaterials scienceCondensed Matter - SuperconductivityMicrowave ResponseMicrowave Coaxial CavitieFOS: Physical sciencesCondensed Matter PhysicsElectronic Optical and Magnetic MaterialsConductorMagnetic fieldSuperconductivity (cond-mat.supr-con)chemistry.chemical_compoundchemistryQ factorMagnesium DiborideMagnesium diborideElectrical and Electronic EngineeringCoaxialComposite materialSheet resistanceMicrowaveIEEE Transactions on Applied Superconductivity
researchProduct

Response time of a thermometer based on normal metal–insulator–superconductor (NIS) tunnel junctions

2003

Abstract We have measured the thermal response of a superconductor–normal metal–superconductor (SINIS) tunnel junction structure at substrate temperature ∼60 mK by directly heating the electron system in the normal metal island. In our structure, we find the response time is determined by the electron–phonon coupling in the electron temperature range 300– 600 mK . By using AC heating, the cut-off frequency caused by this response time has been measured, showing that SINIS structures operate as a thermometer up to a few MHz in this temperature range.

SuperconductivityMaterials scienceCondensed matter physicsResponse timeSubstrate (electronics)Atmospheric temperature rangeCondensed Matter PhysicsAtomic and Molecular Physics and OpticsElectronic Optical and Magnetic MaterialsTunnel junctionCondensed Matter::SuperconductivityThermometerThermalElectron temperaturePhysica E: Low-dimensional Systems and Nanostructures
researchProduct

Time evolution of the microwave second-order response of YBaCuO powder

2003

Transient effects in the microwave second-order response of YBaCuO powder are investigated. The time evolution of the second harmonic signal has been measured for about 300 s after the sample had been exposed to variations of the DC magnetic field. We show that in different time scales the transient response has different origin. In the time scale of milliseconds the transient response of samples in the critical state is ascribable to processes of flux redistribution induced by the switching on/off of the microwave field. At longer times, the time evolution of the second harmonic signal can be ascribed to motion of fluxons induced by the variation of the DC magnetic field. In particular, di…

SuperconductivityMillisecondMaterials scienceCondensed matter physicsFluxonCondensed Matter - SuperconductivityTime evolutionEnergy Engineering and Power TechnologySecond-harmonic generationFOS: Physical sciencesCondensed Matter PhysicsElectronic Optical and Magnetic MaterialsMagnetic fieldSuperconductivity (cond-mat.supr-con)Fluxon dynamics Magnetic relaxation Non-linear microwave responseTransient responseElectrical and Electronic EngineeringMicrowave
researchProduct

Effects of Weak Links in the Nonlinear Microwave Response of MgB2 Superconductor

2006

We report experimental results of second-harmonic (SH) response at microwave frequency in several ceramic MgB2 samples, prepared by different methods. The SH signal has been investigated as a function of the temperature and DC magnetic field. The investigation has been carried out at low magnetic fields, where nonlinear processes arising from motion of Abrikosov fluxons are ineffective. We show that the low-temperature SH emission is ascribable to processes involving weak links. Comparison among the peculiarities of the SH signal radiated by the different samples shows that the presence of weak links strongly depends on the sample preparation method, as well as the purity and morphology of …

Superconductivitymicrowave responseCondensed Matter - Materials ScienceMaterials scienceCondensed matter physicsCondensed Matter - SuperconductivitySettore FIS/01 - Fisica SperimentaleMicrowave responseMaterials Science (cond-mat.mtrl-sci)FOS: Physical sciencesMicrowave frequencyCondensed Matter Physicsweak links.SignalElectronic Optical and Magnetic MaterialsMagnetic fieldharmonic generationSuperconductivity (cond-mat.supr-con)Nonlinear systemmagnesium diboridevisual_artCondensed Matter::Superconductivityvisual_art.visual_art_mediumSample preparationCeramic
researchProduct

Influence of TMS of Supplementary Motor Area on heart rate variability and sympathetic skin responses during processing of negative emotions

2012

Supplementary Motor AreaSympathetic skin responseTMSHeart rateNegative emotion
researchProduct