Search results for "Result"

showing 10 items of 2426 documents

Multi-mycotoxin analysis in wheat semolina using an acetonitrile-based extraction procedure and gas chromatography–tandem mass spectrometry

2012

A new analytical method for the rapid and simultaneous determination of ten mycotoxins including patulin, zearalenone and eight trichothecenes (nivalenol, fusarenon-X, diacetoxyscirpenol, 3-acetyl-deoxynivalenol, neosolaniol, deoxynivalenol, T-2 and HT-2) in wheat semolina has been developed and optimized. Sample extraction and purification were performed with a modified QuEChERS-based (acronym of Quick, Easy, Cheap, Effective, Rugged and Safe) procedure and determined by gas chromatography (GC) coupled to triple quadrupole instrument (QqQ). This is the first paper on the application of GC-QqQ-MS/MS to analysis of mycotoxins. Careful optimization of the gas chromatography-tandem mass spectr…

AcetonitrilesChromatographyGas Chromatography/Tandem Mass SpectrometryCalibration curveFlourLiquid-Liquid ExtractionOrganic ChemistryAnalytical chemistryReproducibility of ResultsGeneral MedicineHydrogen-Ion ConcentrationMycotoxinsQuechersSensitivity and SpecificityBiochemistryGas Chromatography-Mass SpectrometryDiacetoxyscirpenolAnalytical ChemistryTriple quadrupole mass spectrometerPatulinchemistry.chemical_compoundchemistryTandem Mass SpectrometryGas chromatographyGas chromatography–mass spectrometryJournal of Chromatography A
researchProduct

Determination of free formaldehyde in cosmetics containing formaldehyde-releasing preservatives by reversed-phase dispersive liquid-liquid microextra…

2017

Abstract An analytical method for the determination of traces of formaldehyde in cosmetic products containing formaldehyde-releasing preservatives has been developed. The method is based on reversed-phase dispersive liquid–liquid microextraction (RP-DLLME), that allows the extraction of highly polar compounds, followed by liquid chromatography–ultraviolet/visible (LC–UV/vis) determination with post-column derivatization. The variables involved in the RP-DLLME process were studied to provide the best enrichment factors. Under the selected conditions, a mixture of 500 μL of acetonitrile (disperser solvent) and 50 μL of water (extraction solvent) was rapidly injected into 5 mL of toluene sampl…

AcetonitrilesLiquid Phase Microextraction02 engineering and technologyCosmetics01 natural sciencesBiochemistryChemistry Techniques AnalyticalAnalytical Chemistrychemistry.chemical_compoundLimit of DetectionFormaldehydeAcetonitrileDerivatizationDetection limitChromatographyElution010401 analytical chemistryOrganic ChemistryExtraction (chemistry)Preservatives PharmaceuticalReproducibility of ResultsWaterGeneral Medicine021001 nanoscience & nanotechnology0104 chemical sciencesSolventchemistryReagentSolvents0210 nano-technologyEnrichment factorChromatography LiquidTolueneJournal of chromatography. A
researchProduct

Optimised procedures for the reversed-phase liquid chromatographic analysis of formulations containing tricyclic antidepressants.

2003

The chromatographic behaviour (retention, selectivity, peak shape and resolution) of seven tricyclic antidepressants (TCAs), amitryptiline, clomipramine, doxepin, imipramine, maprotiline, nortryptiline and trimipramine, was examined. Conventional unendcapped Cs and C18 columns and an endcapped XTerra MS C18 column recommended for the analysis of basic compounds were used together with acetonitrile-water and micellar sodium dodecylsulfate (SDS)-pentanol mobile phases. The two best combinations were XTerra C18/acetonitrile, which yielded the largest efficiencies and resolution, and C8/SDS-pentanol, which eliminated the peak tails that were still observed with the XTerra C18 column. Both the s…

AcetonitrilesResolution (mass spectrometry)Clinical BiochemistryPharmaceutical ScienceCapsulesAntidepressive Agents TricyclicSensitivity and SpecificityDosage formAnalytical Chemistrychemistry.chemical_compoundDrug DiscoverymedicineAcetonitrileSpectroscopyChromatography High Pressure LiquidChromatographyExtraction (chemistry)Reproducibility of ResultsReversed-phase chromatographyDoxepinTrimipraminechemistry1-PentanolSolventsmedicine.drugTabletsJournal of pharmaceutical and biomedical analysis
researchProduct

Chemical initiation for butyl and lauryl acrylate monolithic columns for CEC.

2009

Butyl acrylate (BA)- and lauryl acrylate (LA)-based monolithic stationary phases for CEC were synthesized, using a redox system as initiator of polymerization. BA monoliths were initiated with ammonium peroxodisulfate, whereas LA columns were obtained with lauroyl peroxide as initiator. In both cases, TEMED was used to activate the process. The influence of porogenic solvent composition on both morphological and electrochromatographic properties of the resulting monoliths was investigated. Excellent efficiencies (minimum plate heights of 4.2-6.3 microm for BA columns and 2.6-5.3 microm for LA stationary phases, for a PAHs mixture) were achieved. The capability of separation of both types of…

AcrylateLipid PeroxidesButyl acrylateClinical BiochemistryInorganic chemistryReproducibility of ResultsLauroyl peroxideEthylenediaminesBiochemistryRedoxAnalytical Chemistrychemistry.chemical_compoundchemistryPolymerizationAcrylatesAmmonium SulfateCapillary ElectrochromatographyMicroscopy Electron ScanningAmmoniumSolvent compositionPolycyclic Aromatic HydrocarbonsGonadal Steroid HormonesNuclear chemistryElectrophoresis
researchProduct

Las dificultades para la educación integradora desde la perspectiva de futuros maestros de inglés

2009

This article presents and analyses the findings of a qualitative study about the perceptions expressed by prospective primary teachers of English about integration and response to special educational needs in the mainstream. The analysis of the data, obtained in the course of the practice teaching period of their course, evidences their ideas on integrative education; besides, a frequent lack of experiences of genuine integrative practices in such a critical period of professional preparation is identified. El presente artículo presenta y analiza los hallazgos de un estudio de naturaleza cualitativa sobre las percepciones que expresan futuros maestros especialistas de inglés en el transcurs…

Actitudes del profesoradoestudiante para profesorintegraciónlengua inglesaeducación especialIntegrative EducationInclusive EducationPreservice TeachersPreservice Teacher Educationresultado de investigaciónEducación inclusivalcsh:LB5-3640Educationformación de profesoresFormación inicial del profesoradolcsh:Theory and practice of educationSpecial Educational NeedsIntegrative Education; Pre-service Teachers; Pre-service Teacher Education; Teacher Attitudes; Special Educational NeedsPre-service Teacher EducationTeacher AttitudesProfesorado en formación inicialPre-service TeachersRELIEVE - Revista Electrónica de Investigación y Evaluación Educativa
researchProduct

Correlation of the highest-energy cosmic rays with nearby extragalactic objects.

2007

Using data collected at the Pierre Auger Observatory during the past 3.7 years, we demonstrated a correlation between the arrival directions of cosmic rays with energy above ~ 6x10^{19} electron volts and the positions of active galactic nuclei (AGN) lying within ~ 75 megaparsecs. We rejected the hypothesis of an isotropic distribution of these cosmic rays with at least a 99% confidence level from a prescribed a priori test. The correlation we observed is compatible with the hypothesis that the highest energy particles originate from nearby extragalactic sources whose flux has not been substantially reduced by interaction with the cosmic background radiation. AGN or objects having a similar…

Active galactic nucleus[SDU.ASTR.CO]Sciences of the Universe [physics]/Astrophysics [astro-ph]/Cosmology and Extra-Galactic Astrophysics [astro-ph.CO]AstronomyAstrophysics::High Energy Astrophysical Phenomenaparticle source [cosmic radiation]Cosmic background radiationFOS: Physical sciencesFluxOsservatorio Pierre AugerCosmic rayanisotropyAstrophysicsAstrophysics::Cosmology and Extragalactic AstrophysicsAstrophysics01 natural sciences[PHYS.ASTR.CO]Physics [physics]/Astrophysics [astro-ph]/Cosmology and Extra-Galactic Astrophysics [astro-ph.CO]Raggi cosmici0103 physical sciencesUltra-high-energy cosmic ray010303 astronomy & astrophysicsBackground radiationNuclei galattivi attiviPhysicsPierre Auger ObservatorySPECTRUMMultidisciplinary[SDU.ASTR]Sciences of the Universe [physics]/Astrophysics [astro-ph]010308 nuclear & particles physicsMedicine (all); MultidisciplinaryMedicine (all)Settore FIS/01 - Fisica SperimentaleAstrophysics (astro-ph)angular dependence [cosmic radiation]Astrophysics::Instrumentation and Methods for AstrophysicsFísicaEnergia ultra altaExperimental High Energy Physicsddc:500Energy (signal processing)experimental results
researchProduct

Development and validation of the SIMPLE endoscopic classification of diminutive and small colorectal polyps

2018

Abstract Background Prediction of histology of small polyps facilitates colonoscopic treatment. The aims of this study were: 1) to develop a simplified polyp classification, 2) to evaluate its performance in predicting polyp histology, and 3) to evaluate the reproducibility of the classification by trainees using multiplatform endoscopic systems. Methods In phase 1, a new simplified endoscopic classification for polyps – Simplified Identification Method for Polyp Labeling during Endoscopy (SIMPLE) – was created, using the new I-SCAN OE system (Pentax, Tokyo, Japan), by eight international experts. In phase 2, the accuracy, level of confidence, and interobserver agreement to predict polyp hi…

AdenomaMODULEValidation studymedicine.medical_specialtyConsensusDelphi TechniqueI-SCANColonoscopyColonic PolypsCOMMUNITY PRACTICE03 medical and health sciencesNarrow Band Imaging0302 clinical medicineEXPERTSPredictive Value of TestsOptical diagnosisADENOMASmedicineHumansHISTOLOGYObserver VariationReproducibilitymedicine.diagnostic_testbusiness.industryGastroenterologyReproducibility of ResultsColonoscopyCOLON POLYPSPredictive valueConfidence intervalEndoscopyTumor Burden030220 oncology & carcinogenesisPredictive value of testsAGREEMENTOPTICAL DIAGNOSIS030211 gastroenterology & hepatologyRadiologybusinessColorectal NeoplasmsEndoscopy
researchProduct

The learning curve, accuracy, and interobserver agreement of endoscope-based confocal laser endomicroscopy for the differentiation of colorectal lesi…

2012

Background: The endoscope-based confocal laser endomicroscopy (eCLE) system allows in vivo imaging of colorectal epithelium. Little is known about the learning curve for accurate interpretation of confocal images acquired with eCLE. Objective: To determine the learning curve of eCLE, its diagnostic accuracy, and the intra- and interobserver agreement for the differentiation of colorectal lesions. Design: Post hoc assessment of selected eCLE images. Setting: Academic centers. Patients: This study involved colonoscopic images from 47 patients. Main Outcome Measurements: Learning curve of eCLE, accuracy, and intraobserver and interobserver agreement. Methods: Three endoscopists received a shor…

AdenomaMalePathologymedicine.medical_specialtyendocrine systemFuture studiesObserver (quantum physics)EndoscopePost hocConfocalColonic PolypsSensitivity and SpecificitymedicineHumansRadiology Nuclear Medicine and imagingStage (cooking)AgedConfocal laser endomicroscopyObserver VariationChi-Square DistributionMicroscopy Confocalbusiness.industryCarcinomaGastroenterologyReproducibility of ResultsColonoscopyMiddle AgedLearning curveColitis UlcerativeFemalebusinessNuclear medicineColorectal NeoplasmsLearning CurveGastrointestinal endoscopy
researchProduct

Comparison of the yield from two faecal immunochemical tests at identical cutoff concentrations – a randomized trial in Latvia

2016

OBJECTIVE We have compared the performance of two faecal immunochemical tests (FIT) in an average-risk population. MATERIALS AND METHODS Altogether, 10 000 individuals aged 50-74 were selected randomly from the population of Latvia in 2011 and assigned randomly either to OC-Sensor or to FOB Gold single-time testing. Positivity of the test, frequency of colonic lesions, number needed to screen (NNscreen) and scope for the detection of an advanced neoplasm (cancer and advanced adenoma) were compared between the tests using the same cutoff concentrations in µg/g faeces. Confidence intervals (CIs) at 95% were calculated. RESULTS Positivity with the cutoff set at 10 µg/g faeces was 12.8% (95% CI…

AdenomaMalemedicine.medical_specialtyPopulationColonoscopyGastroenterologylaw.invention03 medical and health sciences0302 clinical medicineRandomized controlled trialPredictive Value of TestslawInternal medicineHumansMass ScreeningMedicineCutoffeducationFecesAgededucation.field_of_studyHepatologymedicine.diagnostic_testbusiness.industryGastroenterologyReproducibility of ResultsColonoscopyMiddle AgedImmunohistochemistryLatviaNumber needed to screenConfidence intervalOccult Blood030220 oncology & carcinogenesisPredictive value of testsFemale030211 gastroenterology & hepatologyColorectal NeoplasmsbusinessEuropean Journal of Gastroenterology & Hepatology
researchProduct

Interpretation of intraoperative parathyroid hormone monitoring according to the Rome criterion in primary hyperparathyroidism

2022

AbstractIntraoperative parathyroid hormone dosage allows real-time monitoring of the decrease in PTH levels during parathyroidectomy and verify procedure’s efficacy. Currently, none of the interpretative criteria used has absolute accuracy. The aim of this study is to evaluate diagnostic accuracy of the Rome criterion verifying diagnostic significance of the individual assays. A total of 205 patients with primary hyperparathyroidism from a single adenoma were retrospectively evaluated and monitored with baseline PTH, PTH at 10 min and PTH at 20 min after adenoma excision. The accuracy of the latter two assays compared with baseline was compared by ROC curves. In addition, was evaluated the …

AdenomaParathyroidectomyParathyroid NeoplasmsMultidisciplinaryParathyroid HormoneRomeHumansReproducibility of Resultsintraoperative parathyroid hormone monitoringprimary hyperparathyroidismHyperparathyroidism PrimaryRetrospective StudiesScientific Reports
researchProduct