Search results for "Result"
showing 10 items of 2426 documents
Glycaemic variability and inflammation in subjects with metabolic syndrome.
2008
Subjects who develop diabetes have an increased cardiovascular risk even before the appearance of diabetes. The aim of this study was to investigate the glycaemic variability measured by continuous glucose monitoring (CGM CV%) in nondiabetic subjects with metabolic syndrome (MS) and to explore if glycaemic variability was associated with circulating levels of interleukin-6 (IL-6), a proinflammatory cytokine, or with an anti-inflammatory factor like adiponectin. Three groups of obese subjects with (MS+: 6m, 8f; BMI 33.1 ± 1.4 mean ± SEM) or without metabolic syndrome (MS−: 2m, 4f; BMI 29.2 ± 2.2) and with MS associated with type 2 diabetes (MS/T2D: 3m, 5f; BMI 32.9 ± 1.4) were investigated. …
Influence of training and a maximal exercise test in analytical variability of muscular, hepatic, and cardiovascular biochemical variables.
2014
Short, middle, and long-term exercise, as well as the relative intensity of the physical effort, may influence a broad array of laboratory results, and it is thereby of pivotal importance to appropriately differentiate the 'physiologic' from the 'pathological' effects of exercise. Therefore, the values of some biomarkers in physically active subjects may be cautiously interpreted since the results may fall outside the conventional reference ranges. It has been demonstrated that middle and long-term endurance and/or strenuous exercise triggers transient elevations of muscular and cardiac biomarkers. However, no data have been published about the effect of short-term maximal exercise test on …
United States and European Multicenter Prospective Study for the Analytical Performance and Clinical Validation of a Novel Sensitive Fully Automated …
2016
Abstract BACKGROUND The objective of this study is the validation and proof of clinical relevance of a novel electrochemiluminescence immunoassay (ECLIA) for the determination of serum calcitonin (CT) in patients with medullary thyroid carcinoma (MTC) and in different diseases of the thyroid and of calcium homeostasis. METHODS This was a multicenter prospective study on basal serum CT concentrations performed in 9 US and European referral institutions. In addition, stimulated CT concentrations were measured in 50 healthy volunteers after intravenous calcium administration (2.5 mg/kg bodyweight). RESULTS In total, 1929 patients and healthy controls were included. Limits of blank, detection, …
A randomized trial comparing conventional cytology to liquid-based cytology and computer assistance.
2012
Liquid-based cytology (LBC) has replaced conventional cytology (CC) for cervical cancer screening in some countries. However, it remains unclear whether LBC is superior to CC. A randomized controlled trial was conducted between August 2007 and March 2009 in Germany to compare LBC, alone and in combination with computer-assisted imaging technology (CAS), to CC in the detection of histologically confirmed cervical intraepithelial neoplasia (CIN). The main outcome measures were detection rates, relative sensitivities, positive predictive values (PPVs) and relative PPVs comparing LBC without and with CAS to CC. Primary histological outcome was CIN2 or higher. Included were 20,627 women particip…
Axillary Nodal Burden in Breast Cancer Patients With Pre-operative Fine Needle Aspiration-proven Positive Lymph Nodes Compared to Those With Positive…
2019
BACKGROUND/AIM: Recent years have seen a considerable shift to a more conservative management of the axilla in patients with positive axillary sentinel lymph nodes. The aim of this study was to determine whether some breast cancer patients with a preoperative ultrasound-guided needle aspiration biopsy proven positive node could potentially be spared an axillary lymph node dissection according to the ACOSOG Z0011 trial criteria. PATIENTS AND METHODS: A retrospective review was performed involving 623 breast cancer patients who underwent axillary lymph node dissection after either ultrasound-guided needle aspiration biopsy proven positive node or sentinel lymph node biopsy. RESULTS: Patients …
Reproducibility of imaging human knee cartilage by delayed gadolinium-enhanced MRI of cartilage (dGEMRIC) at 1.5 Tesla
2009
Summary Objective The purpose of this study was to investigate the day-to-day reproducibility of the delayed gadolinium-enhanced MRI of cartilage (dGEMRIC) measurement at different knee joint surfaces in healthy subjects at 1.5 Tesla (T). Methods The dGEMRIC experiment was repeated for 10 asymptomatic volunteers three times with an average interval of 5 days between scans. The measurement was performed from a single sagittal slice through the center of the lateral femoral condyle and from the center of the patella in the axial plane. Cartilage was manually segmented into superficial, deep and full-thickness regions of interests (ROIs) at different topographical locations of the femur, tibia…
Assessment of normal patellar cartilage volume and thickness using MRI: an analysis of currently available pulse sequences.
1996
Objective. The objective of this study was to analyse the potential of magnetic resonance imaging for valid determination of patellar cartilage thickness, comparing currently available pulse sequences. Design. In six patients and one cadaver the cartilage was repetitively imaged employing three spin-echo and six three-dimensional gradient-echo sequences. In the cadaveric specimen the total volume and the regional distribution of cartilage thickness were assessed and compared with the values obtained from anatomical sections by image analysis. Results and conclusions. The FLASH and fat-suppressed FLASH sequences allowed the most accurate determination of the cartilage volume and thickness. F…
Magnetic resonance chondro-crassometry (MR CCM): a method for accurate determination of articular cartilage thickness?
1996
A method for the assessment of articular cartilage thickness based on MRI is presented and its accuracy and reproducibility tested. Six specimens of human patellae were imaged, using a fat-suppressed FLASH 3D sequence, and sectioned with a high-precision band saw. The regional distribution of articular cartilage thickness was determined from the MR images and from the anatomical sections (intervals of 0.5 mm). With image analysis 50-90% of the image points were found to lie within exactly the same thickness interval in corresponding patterns, and less than 17% deviated more than 0.5 mm. More than 85% of all pixels were reproducible with MRI after new positioning of the joint. No influence o…
Repeatability of patellar cartilage thickness patterns in the living, using a fat-suppressed magnetic resonance imaging sequence with short acquisiti…
1998
A fast, reproducible, and noninvasive method is required for quantifying cartilage thickness clinically and for studying the deformation of articular cartilage during and after mechanical loading in vivo. The objective of the current investigation was to test the repeatability of regional distribution patterns of patellar cartilage thickness in the living on the basis of a fat-suppressed magnetic resonance imaging sequence with a short acquisition time and three-dimensional digital data processing. The knees of eight healthy volunteers were transversally imaged with a fat-suppressed FLASH-3D (fast low angle shot) sequence (acquisition time: 4 minutes and 10 seconds). In each case, the joint…
Determination of knee joint cartilage thickness using three-dimensional magnetic resonance chondro-crassometry (3D MR-CCM)
1996
The objective of this article was to analyze the accuracy and precision with which the quantitative distribution of articular cartilage can be determined in the knee joint using MRI. A three-dimensional (3D) technique that accounts for the out-of-plane deviation of the interface normal in strongly curved joint surfaces (3D MR-CCM) has been developed for cartilage thickness measurements. Eight cadaveric knee-joint specimens and six volunteers were imaged using a fat-suppressed gradient-echo sequence at a resolution of 2 x 0.31 x 0.31 mm3. Cartilage volumes and topographical thickness maps were obtained and compared with those derived from anatomical sections by image analysis. The deviation …