Search results for "Retention time"

showing 10 items of 71 documents

Optimization of experimental conditions for the identification of pesticide mixtures on six GLC columns

1994

ChromatographyCapillary columnChemistryStationary phaseAnalytical chemistryGeneral MedicineGas chromatographyPesticideRetention timeAnalytical Chemistry
researchProduct

On the measurement of consistent long-term retention factor values in micellar liquid chromatography

2007

Abstract In the field of the quantitative structure–retention and retention–activity relationships (QRAR and QSRR) is crucial to obtain consistent retention factors (k). For this purpose, two unbiased approaches to estimate k are used: (i) the IUPAC approach (based on the extra-column time correction) and (ii) the ‘2-references’ approach (based on the k estimation respect to two prefixed reference k values). Three reference chemicals were selected attending to their retention time, chemical stability and non-ionic character. Consistent retention factor values for these references were estimated for C18 chromatographic columns and Brij35 solutions as mobile phases after statistical analysis.…

ChromatographyChemistryLong term retentionChemical nomenclatureThermodynamicsBiochemistryAnalytical ChemistryColumn chromatographyMicellar liquid chromatographyEnvironmental ChemistryStatistical analysisPhase analysisRetention timeSpectroscopyAnalytica Chimica Acta
researchProduct

Emerging approaches to estimate retention factors in high performance liquid chromatography.

2004

The retention factor is one of the most universally used parameters in chromatography. The errors associated with the conventional ways to determine the retention factor of compounds in liquid chromatography are studied and compared with those corresponding to new approaches. The later avoid the use of extra-column time and hold-up time values, which have proven to be tedious and ambiguous. Simulations and real data, used to examine the accuracy of four different approaches (two classic and two new), suggest that the new approaches could be considered more satisfactory than the classic ones.

ChromatographyChemistryOrganic ChemistryReproducibility of ResultsGeneral MedicineReference StandardsBiochemistryRetention timeHigh-performance liquid chromatographyChromatography High Pressure LiquidAnalytical ChemistryJournal of chromatography. A
researchProduct

A multinjection strategy for mercury speciation.

2005

Abstract A multiinjection strategy has been developed to increase the sampling throughput of the high-performance liquid chromatography determination of inorganic-mercury, methylmercury, ethylmercury and phenylmercury. The method involves the injection of samples each 3.5 min, in spite of the fact that phenylmercury retention time corresponds to 9.04 min. In the selected conditions, the sampling frequency was 11 h −1 in front of that of 6 h −1 , obtained by conventional injection of each sample after the complete elution of Hg species. Additionally, the analytical reagents consumption was reduced drastically in almost 50%. The main characteristics of the chromatographic separation were main…

ChromatographyElutionAnalytical chemistrychemistry.chemical_elementHigh-performance liquid chromatographyAnalytical ChemistryMercury (element)Ethylmercurychemistry.chemical_compoundChromatographic separationchemistryReagentRetention timeMethylmercuryTalanta
researchProduct

Reliability of the retention factor estimations in liquid chromatography.

2004

The retention factor is one of the most universally used parameters in chromatography. However, large differences in the experimental retention factor values are observed when the same compound is injected in a given stationary/mobile phase system under intermediate precision conditions. Conventional protocols for estimating retention factors have problems that mainly arise from difficulties in the hold-up time measurements and the omission of the existence of extra-column times by practicing chromatographers. In the present paper, three different approaches for estimating retention factors are tested: (i) classical retention factor estimations based on the gross hold-up time, (ii) based on…

ChromatographyMicellar liquid chromatographyChemistryOrganic ChemistrySpectrophotometry UltravioletGeneral MedicineBiochemistryRetention timeReliability (statistics)Analytical ChemistryChromatography LiquidJournal of chromatography. A
researchProduct

On the Measurement of Dead Time in Micellar Liquid Chromatography

1996

Abstract Modelling of the retention of solutes in micellar liquid chromatography allows the optimization of the resolution of a mixture of solutes and the determination of physico-chemical retention parameters. Both tasks imply the calculation of capacity factors, which are severely affected by the value of dead time. However, the determination of the dead time is not easy when a micellar mobile phase is used owing to the wide and variable perturbations that appear at the heads of the chromatograms. Four different criteria of determination of a reference time in the chromatograms are proposed and compared. The criteria are applied to mobile phases containing a varying concentration of surfa…

ChromatographyResolution (mass spectrometry)ChemistryClinical BiochemistryAnalytical chemistryPharmaceutical ScienceDead timeBiochemistryCapacity factorAnalytical ChemistryPulmonary surfactantMicellar liquid chromatographyPhase compositionPhase (matter)Retention timeJournal of Liquid Chromatography & Related Technologies
researchProduct

H-point standard additions method for resolution of overlapped chromatographic peaks with a conventional fluorescence detector. Determination of phen…

1996

The H-Point Standard Additions Method (HPSAM) is proposed in order to resolve overlapping peaks in liquid chromatography by using a conventional fluorescence detector. The method uses as analytical signals the heights or the areas obtained at two previously selected emission wavelengths, and good results are obtained for highly overlapping peaks with highly overlapping fluorescence spectra. The principal benefits of the method are the ease of finding the required wavelengths, its insensitivity to changes in the retention time of the peak from one injection to another, and the possibility of using it in highly or only partially overlapping peaks. We have applied the method to the determinati…

ChromatographyResolution (mass spectrometry)ChemistryOrganic ChemistryClinical BiochemistryAnalytical chemistryCresolBiochemistryFluorescence spectroscopyAnalytical ChemistryWavelengthchemistry.chemical_compoundStandard additionmedicinePhenolPoint (geometry)Retention timemedicine.drugChromatographia
researchProduct

Description of the Retention and Peak Profile for Chromolith Columns in Isocratic and Gradient Elution Using Mobile Phase Composition and Flow Rate a…

2014

The effect of the modifier concentration and flow rate on the chromatographic performance of a second generation Chromolith® RP-18e column, under isocratic and gradient elution with acetonitrile-water mixtures, was examined using four sulphonamides as probe compounds. The acetonitrile concentration was varied between 5 and 55% (v/v), and the flow rate between 0.1 and 5.0 mL/min, keeping the other factors constant. The changes in both retention and peak profile were modelled, and used to build simple plots, where the logarithm of the retention factor was represented against the modifier concentration (in gradient elution, against the initial modifier concentration), and the half-widths or wi…

Chromatographyflow programmingChemistryAnalytical chemistryGeneral MedicineReversed-phase chromatographyisocratic elutionFirst generationVolumetric flow ratelcsh:Chemistrymodellingchemistry.chemical_compoundreversed-phase liquid chromatographygradient elutionlcsh:QD1-999ChromolithPhase compositionInteraction kineticsGradient elutionAcetonitrileRetention timeChromatography
researchProduct

Anaerobic thermophilic (55°C) treatment of TMP whitewater in reactors based on biomass attachment and entrapment

1999

Abstract Thermomechanical pulping (TMP) whitewater was treated in thermophilic (55°C) anaerobic laboratory-scale reactors using three different reactor configurations. In all reactors up to 70 % COD removals were achieved. The anaerobic hybrid reactor, composed of an upflow anaerobic sludge blanket (UASB) and a filter, gave degradation rates up to 10 kg COD/m 3 d at loading rates of 15 kg COD/m 3 d and hydraulic retention time (HRT) of 3.1 hours. The anaerobic multi-stage reactor, consisting of three compartments, each packed with granular sludge and carrier elements, gave degradation rates up to 9 kg COD/m 3 d at loading rates of 15–16 kg COD/m 3 d, and HRT down to 2.6 hours. Clogging and …

CloggingEnvironmental EngineeringWaste managementHydraulic retention timeMoving bed biofilm reactorChemistryBioreactorBiomassHybrid reactorPulp and paper industryAnaerobic exerciseWater Science and TechnologyFilter (aquarium)Water Science and Technology
researchProduct

The effect of the solids and hydraulic retention time on moving bed membrane bioreactor performance

2018

Abstract The aim of the present paper was to investigate the effect of solids (SRT) and hydraulic (HRT) retention time on Integrated Fixed Film Activated Sludge (IFAS) University of Cape Town (UCT) membrane Bioreactor (MBR). In particular, three different pairs of SRT and HRT values were analysed, namely, Phase I 56 d/30 h, Phase II 31 d/15 h and Phase III 7 d/13 h. The short-term effect of these three SRT/HRT conditions was assessed by analysing several system performance indicators: organic carbon and biological nutrient (nitrogen and phosphorus) removal, biomass respiratory activity, activated sludge filtration properties and membrane fouling. The results showed that the decrease of SRT/…

DenitrificationHydraulic retention timeIntegrated fixed film activated sludgeStrategy and Management0208 environmental biotechnology02 engineering and technology010501 environmental sciencesMembrane bioreactor01 natural sciencesIndustrial and Manufacturing EngineeringBiological phosphorus removal0105 earth and related environmental sciencesGeneral Environmental ScienceChromatography2300Settore ICAR/03 - Ingegneria Sanitaria-AmbientaleRenewable Energy Sustainability and the EnvironmentChemistryMembrane foulingBuilding and ConstructionNitrogen removalPulp and paper industryMembrane BioReactor020801 environmental engineeringStrategy and Management1409 Tourism Leisure and Hospitality ManagementEnhanced biological phosphorus removalActivated sludgeVolatile suspended solidsNitrificationSolid retention timehuman activitiesHydraulic retention timeJournal of Cleaner Production
researchProduct