Search results for "Retinal"
showing 10 items of 631 documents
Pilot study for the evaluation of morphological and functional changes in retinal blood flow in patients with insulin resistance and/or type 2 diabet…
2012
Background: The aim of this study was to investigate early morphological and functional pathology in the retinal micro-circulation in patients with insulin resistance and/or type 2 diabetes mellitus (T2DM). Methods: Fifty-four subjects, without features of retinopathy under ophthalmological investigation, were recruited for study participation and were classifed into three study groups according to their metabolic staging: (1) Group C comprised nondiabetic, insulin-sensitive subjects with a BMI <28kg/m2; (2) Group IR comprised nondiabetic, insulin-resistant, obese subjects with a BMI ≥28 kg/m2; and (3) Group DM comprised patients with manifested T2DM. Retinal microvascular blood flow was…
OCT is not useful for detection of minimal diabetic retinopathy in type 1 diabetes.
2009
Optical coherence tomography (OCT) has been proven useful in measuring retinal thickness (RT) in patients with diabetes, although with discordant results in different studies. We examined RT in patients with type 1 diabetes (T1D) with or without minimal diabetic retinopathy (MDR) to test whether OCT is able to identify early retinal changes and potential correlations with metabolic parameters. RT of 102 patients with T1D (53 females, 49 males, aged 27.03 +/- 7.4 years) and of 42 healthy controls was examined, with analysis of nine different sectors (fovea, four pericentral and four peripheral sectors). According to the results of basal fundus photography, patients were divided into two grou…
A retinal snap shot may indicate individual risk for cardiovascular disease — The MIPH Eye&Health Study
2014
Examination of retinal vasculature can be used to non-invasively quantify changes within the microvasculature of the human body and might be a predictor of cardiovascular disease. This study evaluates associations of the structure of the retinal vasculature with established risk factors for cardiovascular disease.A cross-sectional study was performed in a working age population. Several systemic cardiovascular parameters were analyzed and PROCAM- and SCORE-risk estimates were calculated. A quantitative ophthalmological examination including digital fundus imaging has taken place. Central retinal arterial/venous equivalents (CRAE/CRVE) and arterio-venous ratio (AVR) were analyzed using valid…
Semi-automated retinal vessel analysis in nonmydriatic fundus photography.
2013
Purpose Funduscopic assessment of the retinal vessels may be used to assess the health status of microcirculation and as a component in the evaluation of cardiovascular risk factors. Typically, the evaluation is restricted to morphological appreciation without strict quantification. Our purpose was to develop and validate a software tool for semi-automated quantitative analysis of retinal vasculature in nonmydriatic fundus photography. Methods matlab software was used to develop a semi-automated image recognition and analysis tool for the determination of the arterial–venous (A/V) ratio in the central vessel equivalent on 45° digital fundus photographs. Validity and reproducibility of the r…
Idiopathic intracranial hypertension: orbital MRI
1995
The case is reported of a patient with idiopathic intracranial hypertension examined with magnetic resonance imaging. Marked enhancement of the optic nerve heads was found, which might be related to blood-retinal barrier breakdown related to a sudden rise in intracranial cerebrospinal fluid pressure.
Retinal Imaging through Phakic Iris-Claw IOL.
2014
AbstractBackground: Phakic anterior chamber iris-fixated IOL (PIOL) are established for the correction of high myopia. These patients require attention to macular pathologies. This study was to evaluate the quality of imaging through the PIOLs. Methods: 54 eyes of 31 myopic and hyperopic patients with Verisyse®, Verisyse toric®, and Veriflex® phakic iris-fixated IOL were included. Mean preoperative refraction was −11.0 D and +5.7 D, respectively; mean follow-up time was 7.4 years (5–11 years). A matched control group was formed without PIOL implantation. OCT scans were performed and evaluated qualitatively and quantitatively. Results: In 52 eyes of 31 patients (96%), a 3D-OCT image and fund…
Risk factors associated with retinal vein occlusion
2014
Summary Aims Retinal vein occlusion (RVO) is the most frequent retinal vascular disease after diabetic retinopathy in which arterial risk factors are much more relevant than venous factors. The objective was to evaluate the role of risk factors in the development of the first episode of RVO. Subjects and Methods One hundred patients with RVO [mean age 56 years, 42% females and mean body mass index (BMI) 27.5 kg/m2] were recruited consecutively from the outpatient clinic of a tertiary hospital in Valencia (Spain). All subjects underwent clinical assessment including anthropometric and blood pressure measurements and laboratory test including homocysteine, antiphospholipid antibodies (aPLAs) …
Prevalence and risk factors of retinal vein occlusion: the Gutenberg Health Study.
2015
SummaryObjective To determine the age- and sex-specific prevalence and determinants of retinal vein occlusions (RVOs) in a large population-based German cohort. Methods The investigation included 15 010 participants (aged 35–74 years) from the Gutenberg Health Study. We determined the prevalence of RVO (central retinal vein occlusion [CRVO] and branch retinal vein occlusion [BRVO]) for the local population by assessing fundus photographs of 12 954 (86.3%; 49.8% women and 50.2% men) participants. Further, we analyzed the associations of RVO with cardiovascular, anthropometric, and ophthalmic parameters. Results The weighted prevalences of RVO, CRVO, and BRVO were 0.40%, 0.08%, and 0.32%, res…
Performance of the compensation comparison method for retinal straylight measurement: effect of patient's age on repeatability
2008
Aim: The assessment of repeatability and reproducibility of retinal straylight measurements with the C-Quant straylight meter (Oculus AG, Germany) and the effect of patient’s age on the instrument performance are tested with a series of experiments. Methods: First, 20 eyes from 20 subjects (mean age 26.9 (SD 2.7) years, mean refractive error −1.34 (2.72) D) were examined with the C-Quant straylightmeter, taking 10 consecutive readings. Five subjects were also examined on five consecutive days to assess reproducibility. Additionally, repeated measures of straylight from 84 subjects of ages ranging from 19 to 86 years (mean (SD): 42.4 (24.0) years) were retrospectively analysed to assess the …
Retinal vascular occlusion and deficiencies in the protein C pathway.
1999
Abstract PURPOSE: To report abnormalities in the protein C pathway and other vascular occlusion risk factors in patients with retinal vascular occlusion. METHODS: In a study, we investigated 76 consecutive patients who had in-patient evaluation of venous or arterial retinal vascular occlusion. All patients underwent comprehensive tests for coagulation disorders including determinations of protein C, protein S, lupus anticoagulants, and resistance to activated protein C and were screened for vascular disease risk factors. Resistance to activated protein C was confirmed by a polymerase chain reaction method to detect the specific factor V R506Q mutation. For comparative purposes, we also scre…