Search results for "Reverse engineering"

showing 7 items of 37 documents

3D RECONSTRUCTION-REVERSE ENGINEERING- DIGITAL FABRICATION OF THE EGYPTIAN PALERMO STONE USING BY SMARTPHONE AND LIGHT STRUCTURED SCANNER

2018

Abstract. This paper presents a pipeline that has been developed to acquire a shape with particular features both under the geometric and radiometric aspects. In fact, the challenge was to build a 3D model of the black Stone of Palermo, where the oldest Egyptian history was printed with the use of hieroglyphs. The dark colour of the material and the superficiality of the hieroglyphs' groove have made the acquisition process very complex to the point of having to experiment with a pipeline that allows the structured light scanner not to lose the homologous points in the 3D alignment phase. For the texture reconstruction we used a last generation smartphone.

lcsh:Applied optics. PhotonicsReverse engineeringScannerComputer scienceComputingMethodologies_IMAGEPROCESSINGANDCOMPUTERVISIONCultural Heritagecomputer.software_genrelcsh:Technology01 natural sciencesStructured-light 3D scanner3D modelingStructured Light ScanningComputer graphics (images)0601 history and archaeologyDigital Fabrication.Groove (engineering)ComputingMethodologies_COMPUTERGRAPHICS060102 archaeologylcsh:Tbusiness.industry010401 analytical chemistry3D reconstructionlcsh:TA1501-182006 humanities and the arts3D sculpting3D modelingPipeline (software)0104 chemical scienceslcsh:TA1-2040Settore ICAR/17 - DisegnoSmartphonelcsh:Engineering (General). Civil engineering (General)businesscomputerCultural Heritage; Structured Light Scanning; Smartphone; 3D modeling; 3D sculpting; Digital Fabrication.Structured light
researchProduct

CAD Modeling for Evaluating LVOT Obstruction in Transcatheter Mitral Valve Replacement

2019

The current generation of transcatheter heart valves (THV), as the Edwards SAPIEN 3 Ultra (S3), is not specifically designed for mitral position implantation and has intrinsic design geometry that may make mitral implantation suboptimal. This study aimed to develop a computed-tomography (CT) based CAD workflow for the preoperative planning of transcatheter mitral valve replacement (TMVR) by evaluating the resulting obstruction in the left ventricular outflow tract (LVOT). Specifically, the computational framework to reconstruct heart anatomy and virtually deploy the THV into mitral valve annulus was developed and successively applied to the cases of two patients who experienced annuloplasty…

medicine.medical_specialtyPreoperative planningbusiness.industryHeart anatomymedicine.medical_treatmentMitral valve replacementCAD030204 cardiovascular system & hematologyVirtual simulation03 medical and health sciences0302 clinical medicineInternal medicineMedical imagingmedicineCardiologyVentricular outflow tractMitral Valve AnnulusCADcardiovascular diseases030212 general & internal medicineMedical imagingbusinessReverse engineeringTranscatheter mitral valve replacementEdwards sapien
researchProduct

Influence of the Screw Positioning on the Stability of Locking Plate for Proximal Tibial Fractures: A Numerical Approach

2020

Tibial fractures are common injuries in people. The proper treatment of these fractures is important in order to recover complete mobility. The aim of this work was to investigate if screw positioning in plates for proximal tibial fractures can affect the stability of the system, and if it can consequently influence the patient healing time. In fact, a more stable construct could allow the reduction of the non-weight-bearing period and consequently speed up the healing process. For that purpose, virtual models of fractured bone/plate assemblies were created, and numerical simulations were performed to evaluate the reaction forces and the maximum value of the contact pressure at the screw/bo…

musculoskeletal diseasesMaterials sciencemedicine.medical_treatmentHealing timelcsh:TechnologyStability (probability)Locking platelcsh:Chemistry03 medical and health sciences0302 clinical medicinemedicineCADGeneral Materials Science030212 general & internal medicineTibial fractureSettore ING-IND/15 - Disegno E Metodi Dell'Ingegneria Industrialelcsh:QH301-705.5InstrumentationReduction (orthopedic surgery)implant stabilityFluid Flow and Transfer ProcessesOrthodonticsFEM030222 orthopedicslcsh:TProcess Chemistry and TechnologyWork (physics)General Engineeringtibial fracturemusculoskeletal systemlocking plateslcsh:QC1-999Finite element methodComputer Science Applicationsreverse engineeringlcsh:Biology (General)lcsh:QD1-999lcsh:TA1-2040Proper treatmentlcsh:Engineering (General). Civil engineering (General)lcsh:PhysicsLocking plateApplied Sciences
researchProduct

Influence of sutures configuration on the strength of tendon-patch joints for rotator cuff tears treatment

2019

Abstract Purpose Massive rotator cuff tears are common in the aging population. The incidence of failed rotator cuff repairs is still quite high, especially in the treatment of full-thickness tears or revision repairs. In this context, natural and synthetic meshes can be used as augmentation scaffolds or as devices to close the gap between a retracted tendon and the bone. The purpose of this work is to evaluate the ultimate tensile strength of different tendon-patch joints in order to consider their use in the treatment of massive cuff tears. Materials and methods Porcine tendons and a synthetic low-density polypropylene mesh have been used. A preliminary study on the tensile strength of te…

musculoskeletal diseasesSwineRotator cuff tearBiocompatible MaterialsContext (language use)Synthetic patchRotator Cuff InjuriesTensile strengthTendonsRotator Cuff03 medical and health sciences0302 clinical medicineExperimental testUltimate tensile strengthAnimalsMedicineRotator cuffRange of Motion ArticularSettore ING-IND/15 - Disegno E Metodi Dell'Ingegneria IndustrialeReverse engineeringJoint (geology)General Environmental ScienceTensile testing030222 orthopedicsSuturesExperimental test; Reverse engineering; Rotator cuff tear; Synthetic patch; Tensile strengthbusiness.industrySuture Techniques030208 emergency & critical care medicinePlastic Surgery Proceduresmusculoskeletal systemTendonmedicine.anatomical_structureModels AnimalCuffGeneral Earth and Planetary SciencesbusinessRange of motionBiomedical engineeringInjury
researchProduct

Biomechanical Analysis of a New Elbow Prosthesis

2019

Total elbow arthroplasty (TEA) is an effective and frequently used treatment for patients with debilitating elbow pathology. Total elbow prostheses have lagged behind those of the knee, hip and shoulder for different reasons, such as the high failure rate of the early designs. Concern remains regarding the longevity of TEA implants, especially in younger patients. The main cause of revision of the implant is usually related to the phenomenon of aseptic loosening mainly due to the cement-bone interface failure. Aim of this work is the biomechanical analysis of a new elbow prosthesis to investigate the mechanical behaviour at the cement-bone interface. For this reason, a musculoskeletal model…

musculoskeletal diseasesTotal elbow arthroplasty FEM Reverse engineering CADFEM030222 orthopedicsbusiness.industryElbowAseptic looseningDentistry030229 sport sciencesmusculoskeletal systemElbow prosthesisTotal elbow arthroplasty03 medical and health sciences0302 clinical medicinemedicine.anatomical_structuremedicineTotal elbow arthroplastyCADImplantSettore ING-IND/15 - Disegno E Metodi Dell'Ingegneria IndustrialeReverse engineeringbusiness
researchProduct

Automated transient hypertext support for software maintenance

2000

reverse engineeringsoftware maintenanceprogram comprehensionprogram analysisprogram slicingylläpitohypertekstiohjelmointiCASE (Computer Assisted/Aided Software Engineering)atk-ohjelmathypertext
researchProduct

Insecure Firmware and Wireless Technologies as “Achilles’ Heel” in Cybersecurity of Cyber-Physical Systems

2022

In this chapter, we analyze cybersecurity weaknesses in three use-cases of real-world cyber-physical systems: transportation (aviation), remote explosives and robotic weapons (fireworks pyrotechnics), and physical security (CCTV). The digitalization, interconnection, and IoT-nature of cyber-physical systems make them attractive targets. It is crucial to ensure that such systems are protected from cyber attacks, and therefore it is equally important to study and understand their major weaknesses. peerReviewed

sulautettu tietotekniikkacybersecurityprotocolsasejärjestelmätilmailucyber-physical systemsfirmwaretakaisinmallinnusvideo surveillanceesineiden internetCCTVkyberturvallisuushaavoittuvuusvulnerabilitieswireless pyrotechnicsremote firing systemsexploitsvalvontajärjestelmätreverse engineeringZigbeeprotokollatcritical infrastructureaviationRFinfrastruktuuritbinareADS-B
researchProduct