δ30Si and δ29Si Determinations on USGS BHVO-1 and BHVO-2 Reference Materials with a New Configuration on a Nu Plasma Multi-Collector ICP-MS
2008
We report silicon isotopic determinations for USGS rock reference materials BHVO-1 and BHVO-2 using a Nu Plasma multi-collector (MC)-ICP-MS, upgraded with a new adjustable entrance slit, to obtain medium resolution, as well as a stronger primary pump and newly designed sampler and skimmer cones ("B" cones). These settings, combined with the use of collector slits, allowed a resolution to be reached that was sufficient to overcome the (NO)-N-14-O-16 and N-14(2) interferences overlying the Si-30 and the Si-28 peaks, respectively, in an earlier set-up. This enabled accurate measurement of both delta Si-30 and delta Si-29. The delta value is expressed in per mil variation relative to the NBS 28…
Insights into the effect of soil pH on N(2)O and N(2) emissions and denitrifier community size and activity.
2010
ABSTRACT The objective of this study was to investigate how changes in soil pH affect the N 2 O and N 2 emissions, denitrification activity, and size of a denitrifier community. We established a field experiment, situated in a grassland area, which consisted of three treatments which were repeatedly amended with a KOH solution (alkaline soil), an H 2 SO 4 solution (acidic soil), or water (natural pH soil) over 10 months. At the site, we determined field N 2 O and N 2 emissions using the 15 N gas flux method and collected soil samples for the measurement of potential denitrification activity and quantification of the size of the denitrifying community by quantitative PCR of the narG , napA ,…
Relative involvement of nitrate and nitrite reduction in the competitiveness of Pseudomonas fluorescens in the rhizosphere of maize under non-limitin…
2002
Competition between different isogenic mutants of Pseudomonas fluorescens unable to carry out the first steps of the denitrification pathway was compared in soil micro-columns non-planted or planted with maize. A new isogenic mutant of P. fluorescens YT101 affected in both nitrate and nitrite respirations was constructed and used as a model of non-denitrifying strain (FM69MS strain). The outcome of the selection exerted by the plant after co-inoculation of FM69MS at the same ratio either with an isogenic denitrifier unable to reduce nitrate (Nar(-) mutant) or with an isogenic NO2 (-) accumulator (Nir(-) mutant) was investigated in non-limiting NO3 (-) conditions. Regardless of the inoculate…
Medication-related osteonecrosis of the jaw associated with implant and regenerative treatments : systematic review
2019
Background The aim of this study was to determine if the treatment with bisphosphonates other anti-resorptive and antiangiogenic agents influences the success of regenerative and / or implant treatments. Material and Methods We reviewed the literature from the last 5 years in the PubMed database, using the following words: “Sinus Floor Augmentation”[Mesh] OR “Dental Implants”[Mesh]) OR “Guided Tissue Regeneration”[Mesh]) AND “Osteonecrosis”[Mesh]. The articles were selected following the inclusion and exclusion criteria and were evaluated using the 22 items of the STROBE declaration. The following PICO clinical question was applied: Does the treatment with agents associated with drug osteon…
Finite Element Method and Von Mises Investigation on Bone Response to Dynamic Stress with a Novel Conical Dental Implant Connection
2020
The bioengineering and medical and biomedical fields are ever closer, and they manage to obtain surprising results for the development of new devices. The field of simulations and studies in silica has undergone considerable development in recent years, favoring the advancement of medicine. In this manuscript, a study was carried out to evaluate the force distribution on the implant components (In-Kone® Universal) and on the peri-implant tissues subjected to loading. With the finite element analysis and the Von Mises method, it was possible to evaluate this distribution of forces both at 0 degrees (occlusal force) and at 30 degrees; the applied force was 800 N. The obtained results on this …
The influence of platform switching on the biomechanical aspects of the implant-abutment system. A three dimensional finite element study
2011
Objective: To evaluate the biomechanical scenario of platform switching geometric implant-abutment configuration relative to standard configurations by means of finite element analysis.Study Design: A 3D Finite Element Analysis (FEA) was performed on 3 different implant-abutment configurations: a 3.8 mm implant with a matching diameter abutment (Standard Control Design, SCD), a 5.5 mm implant with matching diameter abutment (Wider Control Design, WCD), and a 5.5mm implant with a 3.8 mm abutment (Experimental Design, ED). All the different experimental groups were discretized to over 60000 elements and 100000 nodes, and 130N vertical (axial) and 90N horizontal loads were applied on the coron…
Interferometric microscopy study of the surface roughness of Portland cement under the action of different irrigants
2013
Objectives: Some investigations suggested common Portland cement (PC) as a substitute material for MTA for endodontic use; both MTA and PC have a similar composition. The aim of this study was to determine the surface roughness of common PC before and after the exposition to different endodontic irrigating solutions: 10% and 20% citric acid, 17% ethylenediaminetetraacetic (EDTA) and 5% sodium hypochlorite. Study Design: Fifty PC samples in the form of cubes were prepared. PC was mixed with distilled water (powder/liquid ratio 3:1 by weight). The samples were immersed for one minute in 10% and 20% citric acid, 17% EDTA and 5% sodium hypochlorite. After gold coating, PC samples were examined …
Change of arsenite adsorption mechanism during aging of 2-line ferrihydrite in the absence of oxygen
2018
Abstract Arsenite was effectively immobilized by 2-line ferrihydrite at different pH values (4.0, 5.5 and 7.4) and adsorbent dosages (0.4, 1, and 2 g/L) in the absence of oxygen, showing an initial surface diffusion-controlled period (Stage I, 2 h). Dissolved δ 56 Fe increased during Stage I and decreased during Stage II, resulting from aging of ferrihydrite and equilibrium isotopic exchange, respectively. The ferrihydrite aging was hampered by both high As concentrations and high pH values close to the pH zpc , due to inhibition of mineral dissolution as a prerequisite for mineral transformation. During Stage I, As was adsorbed by both bidentate binuclear corner-sharing ( 2 C ) and monoden…
A portable and low cost equipment for flow injection chemiluminescence measurements.
2004
A compact, reliable and low cost flow injection chemiluminescence system is described. The flow system consists of a set of solenoid micro-pumps that can dispense reproductive micro-volumes of solutions. The luminometer was based on a coiled cell constructed from polyethylene tubing that was sandwiched between two large area photodiodes. The whole equipment costs about US$ 750 and weights ca. 3 kg. Equipment performance was evaluated by measuring low concentrations of hydrogen peroxide by oxidation of luminol and for the determination of ammonium, based on its inhibition of the luminescence provided by the reaction of luminol and sodium hypochlorite. Linear responses were achieved within 1.…
Chemiluminescent method for detection of eutrophication sources by estimation of organic amino nitrogen and ammonium in water.
2006
An automatic method has been developed for the estimation of organic amino nitrogen (CH2-NH) and ammonium in water samples. We propose a continuous flow system in which nitrogen compounds react with hypochlorite reagent to produce chloramines. Subsequently, the mixture is mixed with luminol, generating a chemiluminescence signal. The signal emission at 425 nm, registered as a function of time, decreases as nitrogen concentration increases, due to the decrease on hypochlorite concentration. A large number of nitrogen compounds have been assayed and their sensitivities compared, in milligrams per liter nitrogen. The ammonium calibration graph, expressed as N, can be used for most of the assay…