Search results for "Root"
showing 10 items of 1237 documents
A smart rotary technique versus conventional pulpectomy for primary teeth: A randomized controlled clinical study.
2017
Background Techniques with adequate accuracy of working length determination along with shorter duration of treatment in pulpectomy procedure seems to be essential in pediatric dentistry. The aim of the present study was to evaluate the accuracy of root canal length measurement with Root ZX II apex locator and rotary system in pulpectomy of primary teeth. Material and methods In this randomized control clinical trial complete pulpectomy was performed on 80 mandibular primary molars in 80, 4-6-year-old children. The study population was randomly divided into case and control groups. In control group conventional pulpectomy was performed and in the case group working length was determined by …
Three canals in the mesial root of mandibular first permanent molars: a clinical study
1989
Traditional teaching of the anatomy of root canals in different teeth can lead clinicians into the misguided belief that a predetermined number of root canals is always present in any given tooth. A new understanding of the root canal system has enabled the location of additional canals. Results of the clinical study of 760 first mandibular molars, showed that 20 (2.6 per cent) had three canals in the mesial root. Of these 20 teeth, 13 (65 per cent) had an intermediate canal which joined the mesiobuccal canal in the apical third. In six cases (30 per cent) it joined the mesiolingual canal in the same area. In only one case did the intermediate or third canal retain its individual nature and…
Rates of tooth movement and bone remodeling activity : self-ligating versus conventional brackets
2019
Background Bracket systems have been developed with the purpose of reducing frictional resistance between the archwire and accessories. The aim of this research was to compare rates of tooth movement and regions of cellular bone modeling activity along tooth root surfaces of teeth moved with conventional vs. self-ligating brackets. Material and Methods The experiments were conducted in 20 male dogs. Bands were cemented in all intermediate incisors, with conventional brackets (Morelli) on the right side and hybrid self-ligating ones (T3-American Orthodontics) on the left side. A 0.019” x 0.025” stainless steel wire was inserted passively in the slot of these brackets with chain elastics (250…
Comparison of Shaping Ability of 10 Rotary and Reciprocating Systems: an In Vitro Study with AutoCAD
2017
Cilj: Usporediti reznu površinu, očuvanje anatomije korijenskog kanala i neinstrumentiranu površinu nakon instrumentacije sustavima F360®, F6SkyTaper®, HyflexEDM®, iRace®, Neoniti®, O.Shape®, P.Next®, Reciproc®, Revo-S® i WaveOneGold® s veličinom instrumenta 25. Materijali i metode: Tristo zubi s jednim ravnim korijenom i okruglim ili eliptičnim presjekom korijenskog kanala podijeljeno je u 10 skupina (1-F360®, 2-F6SkyTaper®, 3-HyflexEDM®, 4-iRace®, 5-Neoniti®, 6-O Shape®, 7-P.Next®, 8-Reciproc®, 9-Revo-S® i 10-WaveOneGold®) i poprečno prerezano na trećine ultrafinim reznim diskovima. Uzorci su fotografirani pod stereomikroskopom i provedena je predinstrumentacijska analiza prije ponovnog s…
Anterior teeth root inclination prediction derived from digital models: A comparative study of plaster study casts and CBCT images
2018
Background To assess the accuracy of digital models generated using commercially available software to predict anterior teeth root inclination characteristics and compare the results to relevant data obtained from CBCT images. Material and Methods Following sample size calculation and after application of inclusion and exclusion criteria, pre-treatment maxillary and mandibular plaster models and the corresponding CBCT scans of 31 patients attending a private orthodontic clinic were selected. The subjects were 10 males and 21 females with age range 12 to 40 years. Plaster models were scanned using the high resolution mode of an Ortho Insight 3D scanner and CBCT scans were taken using a Kodak…
The accuracy of the Raypex5 electronic apex locator using stainless-steel hand K-file versus nickel-titanium rotary Mtwo file
2009
Objectives: Today many clinicians use both stainless-steel hand K-files and nickel- titanium rotary files during endodontic treatment. It is of great importance for the clinician to have confidence in the accuracy of an apex locator even if these files were used interchangeably. The purpose of this in-vitro study was to evaluate the accuracy of the Raypex5 electronic apex locator using stainless-steel hand K-file versus nickel-titanium rotary Mtwo file. Study design: Twenty straight and single canals of maxillary central teeth were used. Access cavities were prepared; actual working length were determined and compared with electronic working length obtained by means of apex locator Raypex5 …
Root canal treatment of dilacerated second maxillary premolars: Planning the shaping procedure
2018
This article aims at investigating endodontic anatomical variants in the human maxillary premolars allowing the planning of safer and faster shaping procedures. Endodontic literature describes maxillary 2nd premolars as some of the easiest teeth to treat, as they have either one or two straight canals. Rarely they may sometimes have two dilacerated canals. This paper reports two clinical cases of maxillary premolars whose anatomy is quite unusual. In the first case report we describe a maxillary 2nd premolar with a single root and two dilacerated merged canals. The second case report concerns the retreatment of a maxillary 2nd premolar with a single root and two independent dilacerated cana…
Radiographic Investigation of Location and Angulation of Curvatures in Human Maxillary Incisors
2008
The aim of this radiographic study was to evaluate the degree and location of root canal curvatures of human maxillary incisors. A total of 286 extracted human maxillary incisors (145 central and 141 lateral incisors) were included in this investigation. Exclusion criteria were teeth with extensive carious lesions, restorations, and root canal treatment. For this in vitro study, the teeth were fixed in a special device and digitally x-rayed with the parallel technique. The distances from the cementoenamel junction (CEJ) to the first curvature and the according angle were recorded. The results were analyzed descriptively, and p values were calculated with the Wilcoxon Mann-Whitney test. The …
In vitro comparison of root-canal measurements with conventional and digital radiology.
2002
Aim The present study compared the efficacy of digital and conventional radiology for root-canal length measurement. Methodology Seventy extracted teeth with pre-served roots were used. Root-canal length measurements were completed with K-Flexofiles (numbers 08, 10 and 15) with conventional and digital radiography using two systems (radiovisiography and photostimulate storage phosphor). All films and sensors were exposed at projections of 0 degrees and 20 degrees to the mesial. The images obtained were evaluated with and without magnification, and analysed using the Cohen's kappa test. The accuracy of the three systems to determine the root-canal length were evaluated by measuring the dista…
Management of a crown-root fracture : a novel technique with interdisciplinary approach
2018
Anterior teeth with subgingival fractures require a complex treatment plan that addresses biologic, functional and aesthetic factors. This case report describes the management of a crown-root fractured maxillary left central incisor. An interdisciplinary approach was used to restore the tooth due to the complex nature of the treatment. Orthodontic extrusion was performed to move the fracture line above the alveolar bone and periodontal surgery to recontour the altered gingival margin. Finally, the incisor was restored performing a root canal retreatment with a fiber post and a full ceramic crown. The treatment resulted in secured periodontal health and good aesthetics. Key words:Crown-root …